Title Page
-
Site Name
-
Address
-
Operator Ref
-
Date and Time
-
Company
-
Prepared by
Site Information
-
Which operators have equipment on site?
- Vodafone
- Eir
- Three
- O2
- Tetra
- Imagine
Operator equipment
-
How many antennas are installed?
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
-
Are the antennas in the correct position, the correct size and type according to the current as builts?
-
Please provide details and photographs of the current position, size and type of the antennas.
-
How many dishes are installed?
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
-
Are the dishes in the correct position and the correct size according to the drawings?
-
Please provide details and photographs of the current position and size of the dishes.
-
How many cabinets are installed?
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
-
Are the cabinets in the correct position and the correct type according to the drawings?
-
Please provide details and photographs of the current position and cabinets installed
-
Is any other equipment installed on site? (e.g. RRUs, MHAs, DTMAs etc.)
-
Please provide details and photographs of the current position/location and size of any other equipment.
-
Please provide a description and photographs of any equipment on site.
-
Has the lightning protection been tested?
-
Did the LP pass inspection?
-
Date of LP Certificate
-
Has the fall arrest system been tested?
-
Did the fall arrest pass inspection?
-
Date of fall arrest certificate
Trees
-
Are there localized trees within the " Fall Zone" of site?
-
Please supply photos of trees around the site and compound?
-
What is the approximate height of the trees?
-
What is the distance of the trees from the site?
-
Are there any overhanging branches near the site?
-
Are there any signs of damage to the tree trunk or main branches of trees near to the site?
-
Is there any remedial actions required?
PPM Visit Report
-
INSTRUCTIONS
1. Please answer the questions below.
2. If in doubt please add photos and notes by clicking on the paperclip icon
3. Complete audit by providing digital signature
1 - Site Access
-
Please include pictures of the access route from the road/carpark to the site
-
1.1 - Can the site be accessed following the access route shown on the drawings?
-
1.2 - What is the condition of the access gate?
-
1.3 - What is the general condition of the access track?
-
1.4 - Is the access route to site clear of obstacles?
-
1.5 - Is there adequate lighting along the access route?
-
1.6 - Are there any drainage issues to prevent year round site access?
-
1.7 - Is there adequate vehicle access and safe parking?
-
1.8 - General Comments
2 - Site/Compound
-
Please provide pictures of the site/compound
-
2.1 - Is this site fenced?
-
2.2 - Is a combination padlock on the gate installed?
-
2.3 - Are the fence posts secure, stable and in good condition?
-
2.4 - Do the gate pins, bolt & socket allow the gate to operate smoothly?
-
2.5 - Is the fence in good condition?
-
2.6 - Are all barriers/bollards/handrails in good condition?
-
2.7 - Is there any evidence of water ponding on concrete surfaces?
-
2.8 - Is the concrete damaged at any location?
-
2.9 - Is the site free from slips, trips and fall hazards?
-
2.10 - Is the site/compound free from waste, vegetation, vermin/pest infestations?
-
2.11 - Is the ground level equipment installed as per the drawings?
-
2.12 - Are covers fitted to cable ladders / trays where cables are likely to be stepped across?
-
2.13 - Are there cable management systems installed and used correctly?
-
2.14 - General comments
3 - Operator Cabinets
-
Please provide pictures of the cabinets
-
3.1 - Are all cabinet doors & panels secure and locked?
-
3.2 - Are all cabinets the correct type & colour?
-
3.3 - Is the external condition of the enclosure & finish acceptable with no signs of damage?
-
3.4 Is the cabinet sealed where it meets the concrete and plinth/root?
-
3.5 - General comments
4 - Electrical Installation
-
Please provide pictures of RFE's and DB's
-
4.1 - What is the condition of the distribution board?
-
4.2 - Are there any signs of water ingress into the RFE or DB's?
-
4.3 - Are the doors securely lockable on the RFE and DB's?
-
4.4 - Is the ESB equipment in good visual condition?
-
4.5 - Are all devices in the RFE / DB labelled correctly?
-
4.6 - Are all ducts foamed and sealed?
-
4.7 - Are all unused cable glands sealed?
-
4.8 - Are all covers fitted securely to all live parts?
-
4.9 - Meter reading:
-
4.10 - Meter serial no:
-
4.11 - General comments
5 - Lightning Protection
-
Please provide pictures of the LP installation
-
5.1 - Is lightning protection installed as per the drawings?
-
5.2 - Is there LP bonding to compound/ fence?
-
5.3 - Is there LP bonding to the structure?
-
5.4 - Are all steelwork items including gantry poles bonded to the LPS?
-
5.5 - Are all exposed earthing tapes PVC coated?
-
5.6 - Are all earthing tape runs straight?
-
5.7 - Are all changes in direction 90deg with proprietary joints?
-
5.8 Has contact paste been applied to all external LP connections?
-
5.9 - General comments
6 - Structure
-
Please provide pictures of the structure
-
6.1 Is the structure vertical?
-
6.2 - Does the galvanising/painted finish appear in good condition?
-
6.3 - Are there any visible signs of damage/cracks/corrosion on the structure?
-
6.4 - Is there any damage/cracks/corrosion to the nuts, and bolts including holding down bolts?
-
6.5 - Are the holding bolts secure and tight? Refer to manufacturers guidelines
-
6.6 Are all bolts the correct length?
-
6.7 Are flat and spring washer fitted according to manufacturers guidelines?
-
6.8 Have all bolt torque checks been completed in line with manufacturers recommendations?
-
6.9 - Are all welds at the base of the structure free from cracks?
-
6.10 - Are the access hatches secure?
-
6.11 - Is the structure designed to be a climbable structure?
-
6.12 - Is the structure climbable?
-
6.13 Has the fall arrest system been installed as per the manufacturers recommendations?
-
6.14 - Is an anti-climb guard installed with combi padlock fitted & functional?
-
6.15 - Is the system tagged & in date?
-
6.16 - What is the condition of the system / cable?
-
6.17 Are all lanyard hoops in place and secured on all designated working platforms?
-
6.18 Any excess steel/bars causing a hazard to personal whilst climbing?
-
6.19 Is there any damage to the ladder?
-
6.20 - Are there floodlights installed on the structure?
-
6.21 How many lamps are installed?
- 0
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
-
6.22 - Is the floodlight bracket in good condition?
-
6.23 - Is the bracket installed at the height shown on the drawings?
-
6.24 - Is all operator equipment secured with a minimum of 4No. U bolts and plates fixed to the structural elements of the tower
-
6.25 - Are all operator equipment fixing brackets/poles in good working order with no visible signs of corrosion?
-
6.26 Are there any jubilee clips used to support operator equipment?
-
6.27 Are all operator stand off poles vertical and secure?
-
6.28 Has a full inventory audit of the operator equipment been completed?
-
6.29 - General comments
7 - Signage
-
Please provide pictures of all site signage
-
7.1 - Has Shared Access H&S signage been installed on the structure?
-
7.2 - Has Shared Access H&S signage been installed on the compound gate?
-
7.3 - Is all operator signage installed as per the drawings?
-
7.4 - General comments