Title Page
-
Site conducted
-
Australseal Protective Solutions Pty Ltd - ABN: 68633653362 - Address: Unit 37 / 85-115 Alfred Road Chipping Norton, NSW, 2170 Contact Details: admin@aspsau.com - Phone: 02 - 87302970
-
Location:
-
Conducted on:
-
Prepared by:
-
Project Name:
- QN008 - Binah Botany Anlgicare
- QN022 - Binah Fairfield Anglicare
- QN025 - Hutchinson Builders Mainsbridge SSP Warwick Farm
- QN042 - Growthbuilt Mt Druitt SAHF2 Anglicare
- QN044 - Brae Group St Peters
- QN063 - Fal Construction Gilroy College
- QN082 -Ward Erskinville Waterway
-
Manufacturer & Material(s) Used:
-
Area(s) Completed:
Activity
Submission origin:
-
E.g: Onsite / Offsite
Activity
-
Substrate inspected and accepted. Substrate must be clean, smooth, dry and free from dust or contaminants. All sharp points and loose materials have been removed
-
Moisture content of substrate checked and accepted and is below acceptable level. (Non invasive procedure)
-
Primer applied as per manufacturers standards and application guide as per product data sheet (if primer is required)
-
Backing Rod inserted in movement joint and coving fillet applied on joint prior to PVC application.
-
Combiflex system to be installed to the correct manufacturers standards including epoxy reinforcement below and above PVC sheet as per minimum manufacturers requirements and as per AS 4654:2012 and/or AS3740:2021
-
Check Laps, end laps fully/evenly sealed and closed, penetrations sealed, all penetrations have sufficient termination as per manufacturers requirements or specified standards.
-
All welded seams tested with hook probe ensuring proper welds are complete.
-
Final Walk over with main contractor
Final Inspection
-
Client:
-
Client Name & Signature:
-
Date:
-
Australseal Representative Name & Signature:
-
Date:
Photos
-
Photo 1
-
Photo 2
-
Photo 3
-
Photo 4