General Safety Regulations

Personal Protective Equipment & Facilities

  • Has a HIRA been done to determine the need for PPE?

  • Are all PPE & Safety equipment provided free of charge?

  • Are emplyees trained in the correct use, maintenance & limitations of the PPE issued?

  • Employees are not required or permitted to perform work without the use of the required PPE

  • Are employees provided with storage facilities for the safe keeping of their PPE?

  • Employees are not allowed to remove PPE from the premises excl earplugs, overalls, safety shoes

First Aid Equipment & Provisions

  • Are first aid boxes availlable?

  • Are the boxes stocked as per legally prescribed list?

  • Are the location of the first aid boxes indicated by means of signs?

  • Are the names of the first aiders indicated on the first aid box?

  • Are records kept of first aid treatment?

  • Are there at least 1 trained first aider per 50 people during all working hours?

  • Were the first aiders trained on the first aid procedures regarding chemical substances ?

  • Are eye wash facilities available for use by first aiders ?

  • Are emergency showers available where employees are exposed to large amounts of chemicals ?

Use & Storage of Flammable Liquids

  • Are the excess of 40 litres of flammable substancesstored in a flammable liquid store ?

  • Is the flammable store 2 hour fire rared?

  • Is the bunding = 110% of maximum amount of liquids in store?

  • Is the store ventilated to ensure vapours do not accumulate inside the store?

  • Are the followings signs in place ?<br><br>- flammable store sign<br>- no smoking or open flames<br>- max amount of liquid that can be stored

  • Are there adequate amount of fire fighting equipment in the vicinity of the store ?

  • Is the foam inlet & signage in place ?

  • Was the foam dosing devices inspected within the last 12 months ?

  • Is the flammable substance certificate obtain from the local authority ?

  • Is spraying done in a room with an intake & exhaust ventilation system ?

  • Are all the lights & electrical equipment installed of flameproof type ?

  • Is this ventilation system kept clean and in goodworking order ?

  • Has the air speed inside been measured to ensure it conforms to legal requirements ?

  • Is there a second door fitted to the room - only applicable if the room > 20sm

  • Are signs posted prohibiting persons from smoking or open flames ?

  • Are any other electrical equipment only allowed inside once the room has been ventilated ?

  • Are all waste, rags, paper, empty containers removed from the room on a daily basis ?

  • Are there adequite amount of fire fighting equipment in the vicinity of the room ?

  • Are PPE provided for persons doing spray painting or cleaning equipment inside the room ?

  • Are all chemical containers kept close when not in use ?

  • All chemicals kept outside of the flammable store = daily use ?

  • Are the flammable cupboards clean, tidy and kept closed ?

Working in Confined Spaces

  • Is the air inside a confined space being tested anddeclared safe before entering the area?

  • Is this readings recorded?

  • Is the area purged & ventilated before entering?

  • Are all pipes or other openings isolated to ensure no substances, gasses or vapours enter the confined space?

  • If the area cannot be ventilated, is there a breathing equipment available for the person entering the confined space?

  • If the area cannot be ventilated, is there a person outside that monitors the person inside the confined space?

  • In areas containing flammable gasses, are the concentration of those gasses tested & work only allowed if the concentration is below 10% of the lower explosion limit?

Working in Elevated Position

  • Is all work in an elevated position done from a ladder or scaffold?

  • If not using a ladder or scaffold, is the working platform as safe as a scaffold?

Working in Danger of Engulfment

  • Is the person required to enter provided with a safety belt and rope?

  • Is the rope secured by a person standing outside the area of engulfment?

  • Is the person standing outside trained on what actions he need to take in the event of engulfment?

Stacking of Articles

  • Are stacking done by or under the general supervision of a person with specific knowledge & experience of this type of work?

  • Is the base on which stacking is being done level & capable of sustaining the weight of the stacking?

  • Are the articles stacked on the bottom tiers capable of sustainjng the weight placed on them?

  • Are the items stacked in a single tier of the same size, shape & mass?

  • Are the pallets/containers used for stacking in good condition?

  • Is the stability of any stacks in any way endangered by vehicles, persons or machinery?

  • Are the support structure for stacking in good state of repair & can it support the weight of the articles stacked?

  • No person is allowed to climb onto a stack without the use of a ladder?

  • Articles is only allowed to be removed from the top tier?

  • Is the person performing the stacking kept safe and kept outside the reach of machinery that may endanger him?

  • Are stacks that are in danger of collapsing dismantled immediately in a safe manner?

  • Are sacks, cases, cartons or tins stacked in a header & strecher fashion?

  • Are these stacks stepped back half a depth od a single container at least every fifth tier?

  • Do you have an exemption permission from Department of Labour on section 8?

  • When was this exemption issued?

  • Is the stacking observed according to the exemption permission?

  • Are all the requirements according to the exemption permission adhered to? (refer to letter from DoL)

Welding, Flame Cutting, Soldering & Similar Operations

  • Is the person operating the equipment fully instructed in the safe operation and use of such equipment including the hazards which may arise from its use?

  • Is the correct and sufficient PPE issued to the person who operate such equipment?

  • Are the leads and electrode holders effectively insulated?

  • Is the welding & cutting areas partitioned off from other areas to ensure that other persons are not exposed to the hazards?

  • Are both ends of the piping of gas cutting & welding equipment fitted with flashback arrestors if piping > 6m (refer to ISO 5175)

  • If welding / flame cutting to be done in confined spaces, is the area sufficiently ventilated before work commence?

  • If welding / flame cutting to be done in confined spaces, is the person providd with a mask or hood that will supply fresh air?

  • Where welding is to be done in wet conditions, are the electrical insulation in good condition; the electrode holder completely insulated; the welder insulated by means of boots, gloves, rubber mats; a properly trained and capable person to assist in the event of an emergency is in attendance while the work is being done?

  • No welding / cutting is permitted on vessels under pressure or containers that contains a substance that can cause the vessel to explode?

Ladders

  • Are ladders in use constructed of sound material and suitable for its purpose?

  • Are non-skid devices fitted to the bottom ends and devices on the top ends of the stiles of the ladder to ensure that it is stable during normal use?

  • Are free-standing ladders lashed or held in position to ensure its stability?

  • Are the rungs fitted into the stiles of the ladder?

  • Are all the rungs & stiles in good condition?

  • No free-standing ladders > 9m are in use

  • The reach of ladders is not extended by means of fastening together 2 or more ladders?

  • Are wooden ladders constructed of straight grained wood with the grain that is running in the length of the stiles and rungs?

  • Wood ladders are not painted except with a clear varnish or oil?

  • Are persons working on ladders provided with suitable sheaths for the hand tools?

  • Are the rungs of fixed ladders at least 150mm away from the structure to which the ladder is attached?

  • Is the fixed ladder when > 5m fitted with a cage from at least 2,5m from the floor lever?

  • Is the cage on the fixed ladder extending at least 900mm above the top level served by the ladder?

  • Is the cage on the fixed ladder not more than 700mm away from the rungs?

Ramps

  • Is the ramp constructed in accordance with accepted technical standards & have a height to length ratio of 1-8?

  • Are ramps higher than 2m fitted with guard rails with a height of at least 900mm?

  • Are toe boards of at least 150mm height fitted to ramps higher than 2m?

  • Do the ramp conforms to the SANS 10400 - National Building Regulations?

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.