Project Details (Completion of all of the following fields is mandatory. Forms submitted without all fields completed will not be assessed.)
-
Audit Title/Project Description
-
Design Pack ECB Link ID (eg. ABC-1234)
-
Work Parcel/Contract No.
-
Separable Portion No.
-
Order No.
-
Site Address
-
Project Manager
-
Team Manager
-
Authority Number
-
Installer Name
-
Installation Date
Section 1
Rack OMS1460
-
a. No damage to rack (structural /paint /plating)
-
b. Correct Earth tree fitted
-
c. Scratches, exposed rivets covered with supplied patches
-
d. Rack installed in the correct floor position
-
e. Rack installed at the same s/structure height as adjacent racks
-
f. Rack level and plumb (check with spirit level)
-
g. Rack securely attached to superstructure or wall using correct mounting kits and isolation practices
-
h. High superstructure kit “thick washers installed below RH C-channel”.
-
i. Rack securely fixed to floor, using supplied anchors & feet set at 45 degree angle to frame edges
-
j. Rack correctly located over floor tiles (raised floor only)
-
Ref: Design Pack,TM00046
-
*Mandatory photo required - Rack photos showing rack at installation.
Section 2
APDP
-
a. Anderson connectors for each rack primary feed RF1 & RF2 cable tied to prevent accidental pulling apart
-
b. Correct alarm cable and colour code
-
c. Alarm cables terminated correctly on Krone Terminations
-
d. Alarm priority switches set to correct position
-
e No Excessive Cable Lengths APDP
-
f. No permanent alarms on APDP
-
Ref: TM00046 A01
-
*Mandatory photo required - Close-up of APDP showing power terminations & CB’s
Section 3
Rack Primary Power Feed Cables
-
a. Rack power cables correct size
-
b. Rack power cables segregated from the LOD Primary Power 150 mm2 cables
-
c. Rack power cables contained within the power tray
-
d. Cables not damaged/ against a sharp edge
-
e. Rack feed A& B fed from different subracks / planes but same CB position (unless specified in Design Pack)
-
f. Power cable lugs / ferrels crimped correctly / securely at LOD
-
g. Heatshrink on all lugs
-
h. LOD CBs correct type and rating
-
i. LOD CB Locking clip is in the “closed” position
-
Ref: TM00046 A01, CSD 26204
-
*Mandatory photo required - Photo of primary connections at distribution point
Section 4
OMS1410 Subrack
-
a. Subrack installed in correct position as per rack layout
-
b. Power cables run correctly
-
Ref: TAF0001-115198
-
*Mandatory photo required - Photo of subrack showing Power cables ,2 Meg copper, fibre etc.
Section 5
OMS1410 Subrack Mounting Brackets
-
a. Subrack mounting brackets correctly installed and secure
-
Ref: TAF0001-118783
-
*Mandatory photo required - Close up picture of the mounting brackets to confirm that installed correctly.
Section 6
Couplers SFW
-
a. Maximum of 8 SFW couplers installed per tray
-
b. SFW couplers installed in the rear 8 positions of comb<br>
-
c. Fibres to/from the SFW couplers run to the front of tray & form a 1800 bend either clockwise or anticlockwise around the coupler as required to exit the tray
-
d. Thru connector for single fibre side of the coupler is positioned on the opposite side of the coupler entry/ exit point
-
e. SFW Trays correctly modified
-
f. SFW Trays Labelled with “THIS TRAY RESERVED FOR SFW COUPLERS (MAX 8 PER TRAY)”
-
Ref: TAF0001-118783
-
Insert photos please
Section 7
2Mbit Twisted Pair Cabling OMS1410 Subrack End
-
a. Twisted Pair cabling routing correct, neatly run & secured
-
Ref: TAF0001-115198
-
Insert photo please
Section 8
2Mbit Twisted Pair Cabling DDF End
-
a. EQ IN and OUT cables not tied together on long runs
-
b. Cables run and secured correctly down DDF (within guides)
-
c. Cable bending radius not violated
-
d. Correct gooseneck into blocks
-
e. Cable butted correctly at grommet
-
f. Cables not damaged/ against a sharp edge
-
Ref: TM 00099 A01
-
Insert photo please
Section 9
2Mbt DDF Blocks
-
a. Grommets correctly fitted
-
b. Jumper rings fitted & secure
-
c. Back mounts fitted correctly
-
d. Back mounts installed with full compliment of modules
-
e. Label holders fitted to modules
-
f. Wires lay over modules correctly
-
g. Correct wiring, colour code etc
-
h. 100mm tail left behind modules
-
i. Jumpers routed correctly
-
Ref: TM 00099 A01
-
Insert photos please
Section 10
Labelling Rack Header OMS1410
-
a. Rack labelled with rack header label
-
b. Rack labelled with SRPP label
-
Ref: TAF0001-115198
-
*Mandatory photo required - Photo of Rack Header showing both labels
Section 11
Labelling APDP
-
a. APDP Subrack label correct size
-
b. Subrack Position correct format
-
c. RF1 & RF2 , Fuse / Breaker Location correct format
-
d. Circuit Breaker designation for relevant subracks
-
e. Correct ACCADS/TESAMS alarm IDF location
-
*Mandatory photo required - Photo of APDP label, use Macro setting
Section 12
Ericsson Specific Labelling (Supplied Labels)
-
a. Subrack label placed in correct position and contains LIS & NE-ID
-
b. Wrap around labels are orientated so that the text reads away from the connector
-
Ref: TAF0001-655524
-
Please insert photos.
Section 13
Labelling Optical Fibres
-
a. Multiple port card connectors labelled with SLOT & Port number IN or OUT
-
b. Single port cards labelled with SLOT & Port IN or OUT
-
c. Wrap around labels used NO LABEL FLAGS<br>
-
d. Wrap around labels are orientated so that the text reads away from the connector
-
e.Both ends of fibre pigtail labelled<br>
-
Ref: TAF0001-115198
-
*Mandatory photo required - Individual close up photos (Macro setting) of each card to show fibres installed on this project. Try to show Slot & Port number Photo rotated so that label is horizontal on page.
Section 14
Labelling 2M Twisted Pair Cables Subrack end
-
a. Both 2M Twisted Pair cables Eq IN & Eq OUT labelled at the subrack LTU end with SLOT & Port Range 15-20mm from connector around both cables
-
b. 2M cable labels orientated so that they read away from the connector
-
Ref: TAF0001-115198
-
Insert photos please
Section 15
Labelling 2M DDF
-
a. Each Strip contains NE Location
-
b. Each Strip contains NE ID
-
c. Each Strip contains LTU Slot position
-
d. Each Strip contains DDF Block position
-
e. Each Strip contains Port number
-
f. Monitoring ports for relevant LTU’s left blank (PORT 32)
-
Ref: TAF0001-115198
-
*Mandatory photo required - Photos of the front of the blocks clearly showing the label details.
Section 16
Labelling Alarm IDF
-
a. APDP location correct (front of label) F/S/R/Sr
-
b. CB number (rear of label)
-
Ref: TM 00330
-
*Mandatory photo required - Photos or front and rear of the labels.
Section 17
Labelling SFW Couplers
-
a. Label visible without moving coupler
-
b. Label placed in correct position and contains LIS & NE-ID
-
c. All couplers labelled correctly
-
Ref: CSD 26507
-
*Mandatory photo required - Macro close up showing labelling on SFW coupler.
Section 18
Labelling OFDF
-
a. Each Drawer labelled with LiS
-
b. Splice Trays label indicating fibre sheath code & fibre range
-
c. Pigtail labelled with Fibre No
-
d. Patch panel layout card provided & updated to show LiS & relation between Positions on patch panel & Sheath Code/Fibre No.
-
e. Patchcord labelled with Sheath code & Fibre No.
-
Ref: SP000511
-
*Mandatory photo required - Take Photo of either Splice tray or Patch panel depending project
Section 19
Labelling HDODF
-
a. Each Subrack labelled with LiS, Sheath ID, Fibre range & Subrack type
-
b. Trays label indicating fibre sheath code & fibre range
-
c. Pigtail labelled with Fibre No
-
c. Patchcord labelled with Sheath code & Fibre No.
-
Ref: TM00183 A01
-
*Mandatory photo required - Take wide Photo of Patch panel to show tray label fibre numbering & patchcord label
Section 20
Labelling LOD
-
a. LOD panel labelled with LIS, LOD No, Max demand current, where it is fed from, plane & SP & WO
-
b. LOD labelled for correct CB allocation, NE LIS, Feed No & CB rating
-
c. LOD labelled for correct CB allocation
-
Ref: 007 338 E5-6
-
Insert photos please
Section 21
Labelling LOD Power Cables
-
a. Cables labelled at LOD with NE LIS, RF1 or2 & CB position
-
b. Cables labelled at APDP end (RF1 & RF2)
-
Ref: 007 338 E5-6
-
Insert photos please
Section 22
Labelling MRSPP/SRPP Cables
-
a. SRPP label on BOTH Ends of CCB to SPC connecting cable
-
b. SRPP label at 1 Metre interval above/below equipment racks
-
c. SRPP label on either end of the SUITE cable
-
Insert photos please
Section 23
Labelling SPC / CCB bars
-
a. Single Point of Connection Bar marked as “SPC”
-
b. CCB bar labelled CCB and also has an SDH MSRPP /SRPP label
-
Insert photos please
Completion
-
General Comments
-
This is the end of Photo Audit. Your audit result can be found under "Audits" menu. You can edit, preview and send your result via Email