Title Page

  • Document No.1.0

  • Audit Title

  • KLSM Telupid

  • 5 - 6 January 2016

  • Ouzza Ndy Dominic

  • Effluent Site
  • Cassey Leonardus G Toyu

1.0 - Previous Inspection

  • 1.1 - Has the last inspection been reviewed?

  • 1.2 - Are there any outstanding action?

2.0 - Grading

  • 2.1 - Has the 50 random grading being practiced for lorries less than 5 tonnes?

  • 2.2 - Has the 10 random grading being practiced for lorries more than 5 tonnes?

  • 2.3 - Has it call up for joint grading at mill / estate platform?

  • 2.4 - Has bunch marking to trace the errant harvester been practiced hence deter the unripe bunch?

  • 2.5 - Has the quality bonus been practiced for the supplier on trip by trip basis?

  • 2.6 - Has the incentive reached to the staff and foreman?

  • 2.7 - Make sure that there is no unsafe act / condition.

3.0 - Production Process Control – OER

  • 3.1 - Are the oil losses on the press fibre < 7.3% OLDM & < 4.5% OLWB?

  • 3.2 - Are the oil losses on the sludge < 13% OLDM & < 0.8% OLWB?

  • 3.3 - Are the oil losses in the sterilizer < 0.8% OLWB?

  • 3.4 - Are the oil losses on the nut < 0.6% OLWB?

  • 3.5 - Are the unstripped bunches < 3%?

  • 3.6 - Make sure that there is no unsafe act / condition.

4.0 - Production Process Control - KER

  • 4.1 - Are the kernel losses in the cyclone fiber <1% ?<br>

  • 4.2 - Are the kernel losses in the dry shell < 2%?

  • 4.3 - Are the kernel losses in the wet shell < 2%?

  • 4.4 - Are the unstripped bunches < 3%?

  • 4.5 - Are the broken nut to total nut in the press cake < 15%?

  • 4.6 - Make sure that there is no unsafe act / condition.

5.0 - Engineering Control

  • 5.1 - Big sample of 5 kg for checking kernel losses in cyclone fiber.<br>

  • 5.2 - Use of thick bottom ni-hard discharge & cone.

  • 5.3 - Use of 6” x 6” hydrocyclone pump.

  • 5.4 - Expansion column for depericarper.

  • 5.5 - Has bunch crushing / double threshing been practiced?<br>

  • 5.6 - Has steam pipe design ripple mill for efficiency of nut cracking (efficiency > 98%)?

  • 5.7 - Has the expansion column or cracked window for cracked mixture winnower?

  • 5.8 - Has continuous training for mill operator & staff been practiced? <br>

  • 5.9 - Make sure that there is no unsafe act / condition.

6.0 - External Risk – Security Of Palm Product

  • 6.1 - Has inspection for the tanker been carried out? <br>

  • 6.2 - Does a security standby behind the weightbridge to monitor the tanker and kernel trailer?

  • 6.3 - Has the net weight been monitored by the dispatch with flowmeter against the weightbridge?

  • 6.4 - Has the in tag security sealed all the manhole and outlet?

  • 6.5 - Has the gate pass, DN and PL3 been formed in place and applied?

  • 6.6 - Has the CCTV been placed at site and at the weightbridge?

  • 6.7 - Has the tanker been installed with GPS systems?

  • 6.8 - Is the transits insurance in place for each tanker and trailer?

  • 6.9 - Have the tests for FFA, moisture, impurities, and DOBI been carried out for the CPO?

  • 6.10 - Has the trailer compartment been inspected by the security personnel?

  • 6.11 - Make sure that the loaded PK is not excessive and leveled with the trailer body.<br>

  • 6.12 - Has the canvas been secured and locked with link chain and security sealed?

  • 6.13 - Has the gate pass been incorporated with DN?

  • 6.14 - Has the test been carried out for the FFA, moisture, impurities and DOBI for the CPO?

  • 6.15 - Make sure that there is no unsafe act / condition.

7.0 - Optimize Efficiency Of Mill & Reduce Risk Of Stopping In Production Shift Runs.

  • 7.1 - Is there a sufficient storage capacity for CPO and timing off take of the end product? <br>

  • 7.2 - Is there a sufficient storage capacity for PK and timing off take of the end product?

  • 7.3 - Is the downtime > 4%?

  • 7.4 - Has the good preventive maintenance schedule been implemented?

  • 7.5 - Has the DOE standard on smoke density been achieved? (Regimen 2 & CMS)<br>

  • 7.6 - Has the DOE standard of BOD < 20ppm been achieved? <br>

  • 7.7 - Has the DOE standard for zero spillage at the land irrigation been achieved?

  • 7.8 - Has the maximum threshold level for the kernel arrived?

  • 7.9 - Has the maximum threshold level for the CPO arrived?

  • 7.10 - Is there any lack of coordination between the marketing and mill?

  • 7.11 - Is there a minimum spare part available for implementation?

  • 7.12 - Make sure that there is no unsafe act / condition.

8.0 - Major / Critical Machinery Breakdown Prevention

  • 8.1 - Has a proper preventive measurement been implemented? <br>

  • 8.2 - Has a proper RH base preventive measurement been implemented?

  • 8.3 - Is there a proper boiler water logsheet?

  • 8.4 - Has the root cause been traced and adequate capacity for supporting equipment (e.g. softener & daerator) been ensured?

  • 8.5 - Has the contract service schedule been implemented?

  • 8.6 - Is there any measuring tools (e.g. vibration meter)?

  • 8.7 - Has the documentation been carried out for all maintenance and safety procedure?

  • 8.8 - Has the documentation been carried out for raw water and boiler water treatment?

  • 8.9 - Is there a weekly communication with the HOD on mill operation?

  • 8.10 - Is there a sufficient stock of water for dry month ?

  • 8.11 - Is there any competent contractor appointed to do a thorough checking on the weighbridge, water treatment and boiler water treatment, boiler and steam turbine?

  • 8.12 - Has the proper SOP been trained by in-house / outside trainer?
  • 8.13 - Make sure that there is no unsafe act / condition.

9.0 - Cost Efficiency / Competitiveness

  • 9.1 - Is there any daily dispatch records to monitor the stock level and storage capacity?

  • 9.2 - Is there a proper schedule for oil dispatch?

  • 9.3 - Is there a quality control in place to minimize rejection or penalty?

  • 9.4 - Has the rejection target of 0% been achieved?

  • 9.5 - Is there an internal store documentation<br>(e.g. PR)?

  • 9.6 - Has the stock card record been maintained?

  • 9.7 - Is there a running hour machine installed to schedule maintenance and to indicate the life span of the part?

  • 9.8 - Is there any manual for daily cost monitoring using a book keeping?

  • 9.9 - Is there any monthly cost analysis, accounts review & machinery report?

  • 9.10 - Has the store practiced the no replacement without returning the former items ?

  • 9.11 - Is the store keeper keeping track of the minimum and maximum stock level for specific items? <br>

  • 9.12 - Has the manual machinery history card been implemented or the excel spreadsheet been used?

  • 9.13 - Make sure that there is no unsafe act / condition.

10.0 - Mill Throughput Matter

  • 10.1 - Is there a deadline for the submission of daily production report?

  • 10.2 - Have the bottlenecks of the machinery been identified? Rectify the cause.

  • 10.3 - Is there a daily and weekly discussion between the executive and supervisor?

  • 10.4 - Has the management stricten the procedure for overtime?

  • 10.5 - Is the downtime and breakdown report being monitored weekly and monthly?

  • 10.6 - Has the machinery running hour report been implemented and reviewed daily?

  • 10.7 - Make sure that there is no unsafe act / condition.

11.0 - Compliance To Statutory Requirement (DOE, DOSH, MPOB, JBE, Bomba)

  • 11.1 - Is the competent laboratory report being carried out biweekly?

  • 11.2 - Has the discharge maintained a correct loading in accordance to design capacity?

  • 11.3 - Has the SHC been established?

  • 11.4 - Has the annual inspection been carried out based on DOSH?

  • 11.5 - Has the CHRA been carried out?

  • 11.6 - Has the noise monitoring been carried out ?

  • 11.7 - Has the in-house safety talk been carried out by the management?

  • 11.8 - Has the internal safety audit been carried out?

  • 11.9 - Has the quarterly submission to government body like DOE been carried out?<br>

  • 11.10 - Has an independent lab been engaged especially for the test sample related to the DOE matter?

  • 11.11 - Make sure that there is no unsafe act / condition.

Sign off

  • On-site Representative

  • Auditor's Signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.