Information

  • Job Number

  • Inspection Type

  • Lot Address

  • Conducted on

  • Site Manager

  • Inspector

  • Location

FIRST INSPECTION

  • Did the job pass

REINSPECTION

  • Are all items complete

  • REINSPECTION CARRIED OUT BY

  • Select date

LANDSCAPE VIEW

  • Landscape view of all sides.

ENTRY

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Bulkheads/straight/level

  • Columns/straight/square

  • Door studs straightened

  • Plaster margin/door/wind OK

  • Area free of damage from rough in?

  • Hallway walls / parallel

  • General comments

GUEST ROOM

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Bulkheads/straight/level

  • Door studs straightened

  • Plaster margin/door/wind OK

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

GUEST / ENSUITE / POWDER ROOM

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Door studs straightened

  • Niche has fall to front if installed

  • Shower base installed & level (poly marble only)

  • Area free of damage from rough in?

  • Water resistant angles installed to concrete floor where required. Not required on timber floor.

  • Plaster margin 10mm around window

STUDY / SITTING

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Bulkheads/straight/level

  • Door studs straightened

  • Columns/straight/square

  • Plaster margin/door/wind OK

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

FAMILY

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Bulkheads/straight/level

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

KITCHEN

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Bulkheads/straight/level

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

BUTLERS PANTRY

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

DINING/MEALS

  • Ceiling lines at walls OK

  • Walls straightened

  • Ceiling trimming correct

  • Bulkheads/straight/level

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

RUMPUS / THEATRE

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Bulkheads/straight/level

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

LAUNDRY

  • Ceiling lines at walls OK

  • Walls straightened

  • Ceiling trimming correct

  • Bulkheads/straight/level

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

LEISURE/CHILD'S RETREAT

  • Ceiling lines at walls OK

  • Walls straightened

  • Ceiling trimming correct

  • Bulkheads/straight/level

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

MASTER BEDROOM

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Bulkheads/straight/level

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

MASTER ENSUITE

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Door studs straightened

  • Water resistant angles installed to concrete floor where required. Not required on timber floor.

  • Niche has fall to front if installed

  • Shower base installed & level (poly marble only)

  • Bath hob built and level

  • Area free of damage from rough in?

MASTER WIR

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Door studs straightened

  • Noggins to robe returns at 1650mm

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

WC1

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

WC2

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

STAIRWELL

  • Walls plumb through first floor

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

BEDROOM 2

  • Ceiling lines at walls OK

  • Walls straightened

  • Ceiling trimming correct

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

BEDROOM 3

  • Ceiling lines at walls OK

  • Walls straightened

  • Ceiling trimming correct

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

BEDROOM 4

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

REAR HALLWAY

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Door studs straightened

  • Plaster margin 10mm around window

  • Area free of damage from rough in?

  • Wall junctions blocked/nailed

BATHROOM / ENSUITE 2

  • Walls straightened

  • Ceiling lines at walls OK

  • Ceiling trimming correct

  • Door studs straightened

  • Plaster margin 10mm around window

  • Water resistant angles installed to concrete floor where required. Not required on timber floor.

  • Bath hob built and level

  • Niche has fall to front if installed

  • Shower base installed & level (poly marble only)

  • Area free of damage from rough in?

ENSUITE 3

  • Ceiling lines at walls OK

  • Walls straightened

  • Ceiling trimming correct

  • Door studs straightened

  • Plaster margin 10mm around window

  • Niche has fall to front if installed

  • Shower base installed & level (poly marble only)

  • Area free of damage from rough in?

ENSUITE 4

  • Ceiling lines at walls OK

  • Walls straightened

  • Ceiling trimming correct

  • Door studs straightened

  • Plaster margin 10mm around window

  • Niche has fall to front if installed

  • Shower base installed & level (poly marble only)

  • Area free of damage from rough in?

OUTDOOR LIVING / ALFRESCO

  • Ceiling lines at walls OK

  • Ceiling battened at 450 centres and perimeter nogged out

  • If brickwork is complete, is it clear of the beams

  • Are the external doors free of any damage

  • Are the infill s over the external doors complete if required

  • Area free of damage from rough in?

PORTICO

  • Ceiling lines at walls OK

  • Ceiling battened at 450 centres and perimeter nogged out

  • If brickwork is complete, is it clear of the beams

  • Are the external doors free of any damage

  • Area free of damage from rough in?

GARAGE

  • Ceiling lines at walls OK

  • Walls straightened

  • Ceiling trimming correct & perimeter nogs installed

  • Door studs straightened

  • Floor clear of damage

  • Area free of damage from rough in?

  • General comments

BRICKWORK (IF COMPLETE)

  • Bed joints straight and even, 10mm thick not varying by + or - 3mm in thickness

  • Perpends 10mm not exceeding + or - 5mm and not varying by more than 8mm in a wall.<br>

  • Brickwork overhang OK

  • Mortar colour and consistent throughout

  • Brick piers square to the house

  • Are there any blowouts that need to be repaired

  • Clearance to the sill is correct

  • General comments

EXTERNAL

  • Site Cleaned & sloping away from building perimeter

  • Roof tiles bedded and pointed / Tin roof completed

  • Water connected / under pressure

  • Gas line run in complete

  • HWS over flow point brought to surface on left side of HWS pad?

  • Lot sign on and filled in.

  • Eaves complete

  • Infills to windows complete if required.

  • Temp fence installed and secure.

  • Temp down pipes installed. Note if they require maintenance

  • General Comments

Balcony

  • Any damage from rough in

  • Balcony wastes installed

  • Balcony deck is plumb and is sufficiently supported so as not to flex

  • Handrail spigots installed at time of inspection ( If required)

  • Fall protection in place if required

REAR BALCONY

  • Any damage from rough in

  • Balcony wastes installed

  • Balcony deck is plumb and is sufficiently supported so as not to flex

  • Handrail spigots installed at time of inspection ( If required)

  • Fall protection in place if required

OTHER ITEMS

  • Heating/cooling ducts installed

  • Insulation complete

  • Electrical rough in complete

  • Plumbing rough in complete

  • Ducted vacuum roughed in if required

  • Alarm system roughed in if required

  • AG pipes situated 1500mm off house.

  • Check sarking for gaps and holes. Extends over ridge line. Anti ponding boards installed

OVERALL GENERAL COMMENTS

  • Any comments not covered by above categories

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.