1. Handhold clearance - Minimum 2 1/2" vertical, 2" horizontal. (231.29 & 231.30)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
2. Are grab irons properly secured and vertical handholds painted a contrasting color? (231.29 & 231.30)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
3. Steps - Tight & free of cracks, toe plate properly positioned. (Min height of 6" above top of step tread). Step edge fainted a contrasting color. (231.29 & 231.30)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
4. Pilot height - Min 4" ATR Max 6" ATR. (X-2400-15/229.123)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
5. Side bearing clearance - Not permitted to run in contact - Min. clearance 1/32" per side - and side to side not to exceed 1/2" total. (229.69)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
6. Handrails and stanchions - secured properly and no cracks. (231.45)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
7. Brake shoes aligned with wheel, not overriding. (229.57, SMR X-1500-25)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
8. Brake cylinders piston travel - Must provide clearance when brakes are released. Max. travel 6", under slug max. travel 2 1/2". (SMR 1700-01/229.55)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
9. Traction Motor - Leads clamped with all required carbody clamps, and not fouling frame. Insulating sleeves in place, secured with required clamps and free of holes. All covers in place & leads free of oil accumulation. (229.45)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
10. Are all traction motor air ducts in place and free from holes or cracks? (229.45)<br><br>
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
11. Is sanding system operational (229.131) with no leaks & no holes in the hoses.
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
12. Are drain valves functional and in automatic position? Are air dryers and heaters operating properly? (229.46)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
13. Are MU cables in acceptable condition and properly secured? Are all MU pins in place and not burned, covers intact and springs not broken? (229.89)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
14. Do emergency fuel cut-off switches operate properly and labeled? (229.93)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
15. Are flange lube sticks aligned and functional? (SMR X-1400-17)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
16. Have all train line hoses been properly applied, within date, and C/O valve handles painted contrasting color? (X-1000-06, X-9500-06, W-9693, A1105)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
17. Do MU valve handles lock in open and closed position? (229.45)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
18. Make visual inspection of couplers, draftgears and supports. (229.61, X-2700-05)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
19. Was fuel tank properly cleaned? (X-9000-02)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
20. Is locomotive free from air leaks? (X-1000-06, 229.59)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
21. Is locomotive free from fuel leaks? (229.45)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
22. Is locomotive free from oil leaks? (229.45)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
23. Is locomotive free from water leaks? (229.45)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
24. Is locomotive free from exhaust leaks? (229.43)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
25. Is air compressor room and main generator room free of oil, water, waste or obstruction that creates a slipping/tripping hazard? (229.119)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
26. Have carbody & engine been washed? {X-9000-02 & X-9000-04 (184PM)}.
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
27. Are walkways free of oil/sand/debris/obstructions? (229.119)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
28. Have engine & main generator sumps been properly cleaned? (229.119)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
29. Is air compressor discharge pipe properly insulated? (229.41)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
30. Do carbody door latches and hinges operate properly? (229.45)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
31. Have sand trap compartments been cleaned? (X-9000-02 & 04)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
32. Are all fluid levels at the proper level? (X-1700-01)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
33. Are crossover ramps up and secured? (229.119 & X-1700-02)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
34. Are crossover safety chains in good order and properly applied? (229.119 & X-2500-10)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
35. Is hand brake operable, inspection in date & noted on Blue Form? (232.105)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
36. Do all locomotive lights function properly? (229.125 & 229.127)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
37. Are all protective covers in place and applied properly? (229.41)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
38. Are batteries properly blocked, serviced and washed as required? (X-8500-02)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
39. Seats - Inspect all cab seats for defects and proper operation. (229.119)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
40. Have cab seat tracks been cleaned & lubricated if required? (X-2400-01)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
41. Window Glass - FRA approved type only. (223.9 & 223.11) Not scratched or broken and properly cleaned. (229.119 & X-9000-02)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
42. Is all window weather stripping in place and in good condition? (X-2400-22)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
43. Are all required cab and engine decals/plates in place & legible? (X-2400-08, X-9500-06, Danger-High Voltage - 229.85, EPA required E-425-02)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
44. Do the sliding windows move freely, latch securely and are the stops applied?
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
45. Do wipers operate properly and motor covers applied? (X-2400-20, 229.41 & X-2400-08)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
46. Do alarm bell and crossing bell operate properly? (229.115 & 229.129)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
47. Is toilet room door seal in good condition, modesty lock applied and functional? (X-2100-03 & 229.137)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
48. Is toilet room vent routed and/or operating properly? (229.137)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
49. Is toilet bowl and compartment clean and no foul odor present? (229.139)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
50. Does toilet operate properly? (229.139)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
51. Has cab been properly cleaned? (229.119)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
52. Are fire extinguishers secured and valid till next Q? (X-9400-01)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
53. Are electric locker seals & insulation in place and in good condition? (E-2400-12)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
54. Does HVAC system operate properly? (229.119)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
55. Are all holes in cab and toilet room walls sealed to ensure required temperature range in the cab? (229.119)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
56. Is cab floor and trim in good condition? (229.119)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
57. Is ice box door, latch, mounting, hinge & drain in good order? (W-9132)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
58. Are all traction motors cut in with the TMCO sealed? (X-1700-01)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
59. Are speed indicator, speed probes, event recorder, DBCO, CS/TCCO, PTC (if applicable) and GPR properly sealed? (W-9273)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
60. Are radio and HTD properly secured? (X-8000-01)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
61. Are cab door seals, latches and hinges in good condition? (229.119)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
62. Do all cab door locks function and positively lock? (W-9066)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
63. Is unit clear of low voltage grounds? (W-9071)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
64. Is Blue Form properly filled out, dated and displayed? (229.23) <br>When applicable 184 day Q sticker must be applied to Blue Form holder and Mechanical Department Log Form 480-9000007-1 must be completed.
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
65. Are all hose and pipe clamps and brackets properly applied? (229.45)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
66. Have all work report items been properly signed and verified by a supervisor?
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
67. Have all outstanding incidents been repaired & cleared OMIH/CMOR?
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
68. Have all lab alerts been cleared on this locomotive? (OMOL)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
69. Have all dynamic work items been completed in the OMSW screen and the OMLW screen dates up dated?
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
70. Review wheel reports (OMWH). Review prior Q shopping wheel report and access if additional reading required to determine compliance. (X-1400-02 & 229.75)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
71. Have all hot modifications been completed per CMO instructions?
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
72. Is APU functional and switch in proper position? Is exhaust piping secure and vented outside of engine compartment? (X-1700-03 & 229.43)
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
73. Verify horsepower (if possible).
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date
-
74. List separately any identified FRA defects not covered in this checklist.
-
Reviewed With Title / Name
-
Corrective Action
-
Completion Date