Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
Sign In Sheets
-
Are sign in sheets available and filled out for PSM employee training element
Roof
Valve Stations
-
Add media
-
Gauges in place and working properly
-
Defrost pressure between 65-70 PSI
-
Valve stems clean and lubricated
-
Valve stems exercised regularly
-
Pipe plugs in place
-
No evidence of leaks
-
Electrical boxes and conduit in good condition
Crossovers
-
Add media
-
Crossovers in place and in good condition
Pipe Condition
-
Add media
-
Piping in good condition
Insulation / Pipe Saddles
-
Add media
-
Insulation in condition
-
Pipe saddles in place at pipe stands
Pipe Labels
-
Add media
-
Proper pipe labels being used and in place
-
Pipe labels in good condition
Pipe Stands
-
Add media
-
Pipe stands in place and properly supporting pipes
Rain Cover On Relief Line
-
Add media
-
Rain cover in place on relief line to prevent contamination
Vent Line Sensor
-
Add media
-
Vent line sensor in place and 15 feet above working surface
Exhaust System
-
Add media
-
Exhaust system operates when ammonia is detected
-
Exhaust system meets IIAR2-2008 standards
-
Fan belts in good condition
-
Fan blades in good condition
-
Intake dampers working properly
-
Exhaust fans can be started manually from outside the engine room
Condenser
-
Add media
-
Fans in good condition
-
Fan belts in good condition
-
Fan blades in good condition
-
Bearings in good condition
-
Piping in good condition
-
Paint on piping in good condition
-
Tubes in good condition - check for corrosion and scaling
-
Nozzles have good water pressure and coverage over tubes
-
Drift eliminators in place and in good condition
-
Water sump clean and free of debris
-
Water pumps running properly with no leaks
-
Relief valves removed from condensers
-
Structural steel in good condition
-
Electrical conduit and junction boxes in good condition
-
Water treatment in place and effective
-
Valves in good working condition
-
Access to valves and nozzles easily accessible
Purger
-
Add media
-
Equipment clean and bubbler easy to see through
-
Insulation in place and in good condition
-
Purger operation working properly
-
Purger cycle counts recorded
DHU
-
Add media
-
Valves in good working condition
-
Sensors in place and working properly
-
Filters in place and not clogged
-
Belts in good working order
-
Desiccant wheel in good working condition
-
Equipment operating properly
Machine Room
Glycol Loop
-
Add media
-
Heat exchanger working properly
-
Relief valves in place and in compliance
-
Glycol pump working and in good condition
-
Glycol temperature between 40-50 degrees
-
Glycol flow is appropriate
-
Glycol liquid level is appropriate
-
Glycol valves in good condition
-
Glycol temperature probes working properly
HVAC
-
Add media
-
Heat exchanger working properly
-
Relief valves in place and in compliance
-
Pump in good working order
-
Temperature set properly
-
Glycol flow is acceptable
-
Valves in good working order
-
Temperature probes working properly
Condenser Pumps
-
Add media
-
Condenser pumps working properly with no leaks
Cross Connection Regulator
-
Add media
-
Cross connection regulator set properly and working
Compressors - Screw
-
Add media
-
Name plate legible
-
Relief valves in place and in compliance
-
Gauges in place and in good working condition
-
Economizer working properly
-
Set points set up properly
-
Guards in place
-
Filter pressure within acceptable limits
-
Operating limits are good
-
Anchors and grouting in good condition
-
Safety switches in place and working properly
-
Oil quality and changing is based on oil sampling analysis
-
Sensors reading accurately
-
Equipment is clean
-
Equipment is operating properly
-
No oil leaks are evident
-
Valves are in good shape and working properly
-
Starters are in good condition and working properly
Compressor - Reciprocating
-
Add media
-
Name plate legible
-
Relief valves in place and in compliance
-
Gauges in place and in good working condition
-
Economizer working properly
-
Set points set up properly
-
Guards in place
-
Filter pressure within acceptable limits
-
Operating limits are good
-
Anchors and grouting in good condition
-
Safety switches in place and working properly
-
Oil quality and changing is based on oil sampling analysis
-
Sensors reading accurately
-
Equipment is clean
-
Equipment is operating properly
-
No oil leaks are evident
-
Valves are in good shape and working properly
-
Starters are in good condition and working properly
Vessels
-
Add media
-
Name plate / ASME stamp legible
-
Level controls working properly
-
Bulls eyes in good condition
-
Oil pots in good condition
-
Insulation in place and in good condition
-
Feed valves working properly
-
Safety float cut outs working properly
-
Relief valves in place and in compliance
-
Vessel is in good condition
-
Piping in good condition
-
Equipment is clean
-
Valves in good working condition
-
Electrical conduit and junction boxes are in good condition
-
Equipment is operating properly
Oil Recovery System
-
Add media
-
Oil recovery system in good condition and working properly
Floors
-
Add media
-
Floors in good condition
Walls
-
Add media
-
Walls are in good condition
Electrical / Panels
-
Add media
-
Electrical panels are in good condition and doors closed
-
No open holes are in panel, especially the top
-
If filters are in panel filter is clean and fits opening properly
Spare Parts
-
Add media
-
Spare parts are in Maximo and on cycle counts
Clutter / Unauthorized Material
-
Add media
-
No unauthorized storage in a machine room. Only refrigeration equipment and parts allowed
Ladders
-
Add media
-
Ladders are designated for machine room
Labels
-
Add media
-
Pipe and equipment labels are in place and meet IIAR standards
Pipes
-
Add media
-
Pipes are in good condition and painted
Insulation / Pipe Saddles
-
Add media
-
Insulation is in good condition and pipe saddles in place
High Pressure Reciever
-
Add media
-
High pressure receiver is in good condition
Ammonia Dispersion Tank
-
Add media
-
Dispersion tank is in good condition with no leaks
Transfer Hose
-
Add media
-
Transfer hose is suitable and certification date is not expired
Ammonia Level
-
Add media
-
Ammonia level within acceptable range