Title Page
-
Site conducted
-
Job Number
-
Conducted on
-
Location
GENERAL
-
Builder's Sign on Site and Visible
-
Bin on Site
-
Site Safety Management Plan check
-
Check services installed in correct location
PAVING
-
Ensure adequate set down from finish floor (minimum 50mm)
-
Viscourse is installed and trimmed
-
Ensure floor gully is 50mm below finished floor level and is taped off to avoid blockage
-
Ensure falls are adequate, 1 in 20 minimum for first metre from wall
-
Paving pattern installed as per selections sheet
-
Paver colour and thickness as per selection sheet
-
Paving sand and haunching installed
-
All sewer and stormwater IPS installed and covered (150mm bolted trap screw)
-
All stormwater grates (grey) to be installed
CONCRETING
-
Ensure services installed where required
-
Ensure adequate set down from finish floor (minimal 50mm)
-
Termite treatment (installed where required)
-
Installed as per selection sheet & landscaping plan
-
Ensure junting/edges are left neat clean
-
Ensure crossover/inverts are completed where required
-
Ensure all concrete splashes are cleaned off appropriately
-
Trim viscourse to top of concrete and Ableflex around stormwater
-
Rainwater tank pads to be concrete only
-
Remove any drag out to roads immediately
ACKNOWLEDGEMENT
-
I have read and understood the requirements of this audits as stated in Rivergum Homes Policies and Procedures