Title Page
-
Branch
- Accrington
- Birmingham
- Bury St Edmunds
- Crawley
- Crayford
- Darlington
- Exeter
- Gloucester
- Milton Keynes
- Newbury
- Nottingham
- South Wales
- Warrington
- Wombwell
-
Conducted on
-
Prepared by
-
Location
-
Contract Number
-
Scaffolding Company
- ALLRISE Scaffolding
- 365 Scaffolding
- 7 Hills Scaffolding
- A&R Elite Scaffolding
- Bearsted Scaffolding
- CHEM Scaffolding
- Global Platforms Scaffolding
- N.E. Scaffolding Services
- Philip Steele Building Equipment
- Reach Scaffolding
- RISE Scaffolding Midlands
- R S Scaffolding
- SCAFFTEC
- SDA Scaffolding
- Solar Scaffolding Services
- St. George Scaffolding
- TC Scaffolding
- Teeside Scaffolding
- T.J.M Groundwork and Building Contractors
- Wilkes & Sons
- CHRIS EVANS
- UPRIGHT SCAFFOLDING
- BAF
- SK Scaffold
- SR Scaffold
- Customer Supplied Scaffolding
- Other (please comment)
Inspection Page
Scaffold tag
-
Is the scaffolding structures on site adequately tagged and in date (1 tag per 3 structures)
-
Work must be suspended if the scaffolding is not adequately tagged.
-
Please select the issue
- Fitted but out of date
- Can not read the details on the tag
- Tag not fitted or in holder
-
Please select scaffolding type
- Free standing
- Pavement
- Bridging
- Cantilever
- Edge protection
- System
- Survey scaffold
- Tower
- Facia Soffit Guttering Access
-
Free standing scaffolding location
- Front of property
- Left hand side of property
- Right hand side of property
- Back of property
- Public footpath
-
Pavement scaffolding location
- Front of property
- Left hand side of property
- Right hand side of property
- Back of property
- Public footpath
-
Does it meet local authority requirements
-
Work must be suspended on this scaffold.
-
Please select the issues
- First Lift too low
- No dawn till dusk lighting
- Built too close to road
- No brick guards
- No protective foam fitted to prevent injury
-
Bridging scaffolding location
- Front of property
- Left hand side of property
- Right hand side of property
- Back of property
- Public footpath
-
Cantilever scaffolding location
- Front of property
- Left hand side of property
- Right hand side of property
- Back of property
- Public footpath
-
Edge protection scaffolding location
- Front of property
- Left hand side of property
- Right hand side of property
- Back of property
- Public footpath
-
System scaffolding location
- Front of property
- Left hand side of property
- Right hand side of property
- Back of property
- Public footpath
-
Is the manufacturer's instruction available with the structure?
-
Suspend work and contact access solutions
-
Are the instructions available from another source? (e.g. an email)
-
Does it comply with the manufacturer's building instructions?
-
Work on this scaffold until this issue is rectified.
Footings
-
Is the scaffold built on firm ground
-
Have base plated been used
-
Are timber sole boards in place and at the correct dimensions 450mm x 225mm x 38mm
-
Are they in good condition
Standard poles
-
Are the standards level / within tolerance
-
Are joints staggered and not in the same bay on scaffolding above 4 Lifts
Ledgers
-
Are ledgers horizontal
-
Are joints staggered where possible
-
Is the first lift set at a height of no more than 2.7M maximum where site conditions allow
Transoms
-
Are the transoms the correct spacings
-
Are the transoms within 300mm of a standard
-
Are the transom lengths sufficient
-
Is there a transom fitted within 300mm of the node point
The scaffold
-
Does the scaffolding allow safe access to the property
-
Does the scaffolding have suitable pole protection against impact from the public where required
-
Is it required?
Ledger, Facade and plan Bracing
-
Is the facade bracing fixed to the standard between 35 and 55 degrees where required
-
Is the ledger bracing fitted to every other pair of standards for the full height of the scaffold where structural transoms are not in place
-
Is the facade and ledger bracing fitted within 300mm from the node point
Scaffold Ties
-
Are sufficient ties used in accordance with TG:4
-
Please select the type of ties used
-
Are they connected within 300mm of a standard?
-
Are they fitted with right-angled couplers?
-
Are they connected to internal and external standards?
-
Are they connected to the scaffold at 2 points?
-
Is there a joint in the raker?
-
Are they within 300mm of a standard?
-
Is the box tie connected to steel or masonry
-
Have steel connectors been used?
Boarded Lift
-
Are the boards correctly supported and secure
-
Are the boards undamaged
-
Are there any lapped boards
-
Are there any gaps in the boards greater than 45 mm
-
Are boards less than 2.13m secured to the scaffolding
-
Are the inside boards fitted
-
Do all standards project a minimum of 1m through the lift and capped off
Handrails, Toe Boards and Brick Guards
-
Are guardrails secured to the inside of the standards with double couplers
-
Are guardrails fixed at 950mm from the top of the toeboards
-
Are intermediate guardrails set at a maximum of 470mm from the top rail
-
Are toeboards secured to the inside of the standards with 2 clips minimum
-
Are brick guards fitted on working lifts where there is a risk of falling materials / tools
Fall protection
-
Please select the type of fall protection installed (select all that apply)
- Gate
- Trap door
- Full enclosure
- Staircase fitted
- None available
Ladder / Stair Access
-
Has an extended transom been fitted to the intermediate rail of the 1st boarded lift?
-
Has a staircase been fitted to the scaffolding
-
Is there an internal ladder from the first lift
Tubes and fittings
-
Are the tubes and fittings in good order
-
Have the correct couplers been used
-
Have the fittings been properly tightened
-
Are check coupler fitted where required
Power Lines
-
Any power lines within a 6 meter proximity of the scaffold must be protected with sheathing to prevent electrical arcing
-
Is the Scaffold within 6 meters of a power line
-
Has the power line been made safe / Insulated / Isolated
undefined
-
Is the scaffold the correct Duty rating for the work being carried out
-
Does the scaffold allow access to ground floor frames
-
Is the scaffold fit for its intended use
Lifting Equipment
-
Gin Wheel Fitted where required?
Inspection summary
Scaffold
-
Does the scaffolding appear to be erected in accordance with TG20 guidance
-
Is the scaffold safe to use
-
What are the issues
- No scaff tag
- scaff tag out of date
- Raker not tied back
- Missing guardrail
- No safety gate
- No ladder secure point
- Gaps in toeboard
- Power cable concern
-
Work must be suspended on this scaffold.
Sign-off
-
Add signature