Title Page
School Building Accessibility Checklist
-
School Name
-
Conducted on
-
Prepared by
-
Location
School Entrance
-
Gradients of entrances are ≤ 5% ?
-
When several paths, do both accessible and inaccessible marked ?
-
If accessible door not the main door, is it marked with directional sign ?
-
Are identification number and exact address for each entrance available ?
-
In public use buildings, are reception desks near the entrances ?
-
Are the dimensions of doors ≥ 900mm width x 2100mm height ?
-
Are automatic doors available ?
-
Do automatic doors take 3 seconds or more to move from closed to fully open position -Remain fully open for a minimum 5 seconds -Force not more than 66N ?
-
Are doormats levelled with ±2mm ?
-
Are access controls barriers with at least one barrier with width ≥ 900mm? (if provided)
School Counters and reception areas
-
Are reception areas provided with seating places and interaction spaces ?
-
Are front desks provided with accessible interaction space ?
-
Are low counters height between 750-790mm ?
-
Are high counters height between 950-1250mm ?
-
Under the desk a space of 680 mm height and 480 mm deep
-
When required, hearing enhancement systems using induction loop, infrared and radio frequency are provided
-
Is the hearing enhancement system provided with international symbol for hearing loss, when access needed ?
Schoo Paths :Accessible path of travel - External Areas
-
Are the external walking paths width is 1800mm without obstacle, from the parking to the entrance, segregated from traffic circulation ?
-
Are the external walk paths Linear and continued?
-
Are intersections clearly visible with signs or lights ?
-
Gradient is ≤ 5% ?
-
Clear headroom are ≥ 2200mm
-
Absence of uneven Surfaces - irregularities are ≤ 5 mm ?
-
Absence of protruding objects, or objects protruding are less than 100mm from façade<br>or objects protruding more than 100mm, extends to the floor surface or above the floor level by maximum 300mm ?
-
Furniture comply with detection cone rule
-
Illumination level is ≥ 10 lux ?
-
No drain grids on accessible crossings (outside the intersection)
-
Free of obstacles and located between the building's façade and the furniture zone
-
Parking entrance do not modify the slope or width of the accessible path
-
Curb height is between 100 mm and 150 mm
-
Cross slope gradient is ≤ 2%
-
Pedestrian bridges provided with ramps or elevators (if provided)
School Floor Surface
-
Slip resistance (PTV) comply: Level and inclined with ≤ 5% dry areas indoor -(PTV) Between 15 and 35
-
Slip resistance (PTV) comply: Inclined > 5% dry areas indoor, (PTV) ≥ 35
-
Slip resistance (PTV) comply: Level and inclined with ≤ 5% wet areas and outdoor -(PTV) Between 35 and 45
-
Slip resistance (PTV) comply: Inclined > 5% wet areas and outdoor,(PTV) ≥ 45
-
Slip resistance (PTV) comply: Street pavement, swimming pools and showers, (PTV) ≥ 45
-
Ground pavement without loose elements
-
Rugs and carpets are firmly fixed and do not increase the strength required to roll over a ceramic pavement by ≥ 25%
-
Floor surfaces without rounded edges and excessive joints
-
Floor surfaces not producing glare
-
Provided with reflectance contrast of at least 30 points LRV between accessible pavement (surrounding surface or 300mm pavement strip)
-
Lighting in floor (Flooring Light) is not producing glare and excessive heat
-
Absence of utility covers (manhole covers) on the path or with height less of 5 mm
-
Absence of drain grids on the path or with holes smaller than 5 mm
-
Change of pavement level ≤15mm, with ≤25% gradient slope (chamfered)
-
Longitudinal grate openings with perpendicular orientation to the pedestrians direction of travel
-
For distance between tree basin edge and the façade < 1800 mm, tree grate with walkable surface
School Internal Corridors
-
Corridors Width ≥ 1000 mm
-
In direction changes a Maneuvering space of 1200 mm
-
Tactile warning surface in any change of level
-
Illumination ≥ 60 lux
-
Clear headroom ≥ 2200mm
-
Absence of protruding objects, or objects protruding less than 100mm from façade, or objects protruding more than 100mm, extends to the floor surface or above the floor level by maximum 300mm
School Level Changes; Guardrails
-
Absence of unprotected level changes -guardrails for heights ≥ 500mm
-
Height ≥ 1100mm
-
With sufficient strength and stiffness to withstand horizontally uniformly distributed force of 3 kN/m
-
Can not be climbable
-
Width of Horizontal and Vertical openings ≤ 100mm
-
Availability of continuous base on the entire open side length and continuous base ≥ 100mm high from the floor surface for ramps & stairs
School Warning tactile surface
-
Available in the beginning and end of every level change including ramps and stair landings , or any dangerous element
-
Installed along the entire width of the element
-
The width ≥ 300mm
-
Located at 300mm away from the edge of the ramp or stair flight or any dangerous element
-
Warning tactile truncated cones diameter = 30mm at bottom and 20mm at top, and protruding 4mm
-
Non glare or shiny or slippery
School Ramps
-
Ramps used only when gradient of level >5%
-
Slope is ≤ 8% or 1:12
-
Cross fall gradient ≤ 2%
-
Run length ≤ 10 meters
-
Run width = 1000 mm between handrails
-
No curved ramps
-
Landings at the beginning and end of every run -surface 1500 mm x 1500 mm
-
Level landings or ≤ 2%
-
Corridors in landings width ≥ 1200 mm width
-
No door located at ≤ 1500mm from start and or end of each ramps
-
School Stairs
-
Availability of alternative elevator accompanied with internal staircase in more than one story building
-
Steps rises between 150 -175 mm
-
Steps stair treads between 300 -340 mm
-
Steps rise (R) and Tread (T) fulfil: 600 mm < 2R + T < 650 mm
-
No curved stairs
-
No open risers or discontinued treads
-
Steps with nosing ≤ 25 mm
-
30 mm from the step edge space along the stair flight width shall present a reflectance contrast of 30 LRV
-
Steps with same height with a ±4 mm tolerance
-
Stair flights steps number between 3 and 12
-
Usable stair flight width ≥ 1100 mm
-
Illumination at top and bottom of the flight ≥ 200lux
-
Landing with same width of stair and a length ≥ 1200 mm
-
Empty space with height < 2200 mm under the stair is protected
School: Handrail for Ramps and Stairs
-
300 mm horizontal extension at its ends
-
Presence of intermediate handrail for stairs to keep distance of at most 2100 mm
-
Mounted at Height of 900 mm
-
Additional handrail at a height between 650 -750 mm
-
In ramps The distance between both sides of handrails is 1000mm
-
Rounded section of 30 -40 mm separated from the wall with a distance ≥ 40 mm
-
Handrails designed to allow continuity of gripping without interfering its mounting system
-
Contrast of 30 LRV against its background
-
Handrails made of comfortable materials against heat and coldness
School Elevators
-
Present in buildings with more than one floor
-
Accessible from ground floor in public areas
-
Dimensions shall comply: One door ≥ 1200 x 1500 mm Two opposing doors ≥ 1200 x 1500 mm Two doors in 90°≥ 1500 x 1500 mm
-
Automatic doors with a width of 900 mm and colour contrast against walls
-
Maneuvering space of 1500 x 1500 mm in front the elevator access
-
Elevator calling buttons height between 900 -1200 mm
-
Floor indicator located at 1830mm
-
Only one mirror inside the cabin on the wall opposite to the door over the handrail level
-
Inside the cabin, minimum two handrails at a height of 800 mm to 1000mm from the floor
-
Inside the cabin, buttons height between 900 -1200 mm with Braille
-
The ground floor button protruded ≥ 3 mm distinguished with a green color
-
Call buttons distinguished with icons and color contrast against background
-
Buttons provide two-channel feedback/ visual & acoustic OR visual & tactile
-
Emergency phone number is indicated by graphic and tactile
-
CCTV or intercom or alternative system
-
Light on the ceiling only with 100 lux
-
In panoramic elevators, an opaque wall or corner is provided
-
Automatic doors open at least 3 seconds
-
Doors provided with sensors at two levels open automatically
-
Door force less than 135N
-
Indication sign of accessible elevator direction when various options of vertical circulation
-
Braille & tactile signage on the door jamb at 1500mm height
-
Audible signal or voice announcement when reaching each floor
-
Advisory signs indicating safety procedures and other regulatory information
Lift Platforms, if provided
-
Dimensions of the cabin on min. 900 x 1500 mm
-
Maneuvering space of 1500 x 1500 mm in front the lift access
-
Calling button height between 700 -1200 mm
-
Doors width of 900 mm
-
Cabin with side protections to isolate users from side walls
-
Inside the cabin, minimum two handrails at a height of 800 mm to 1000mm from the floor
-
Inside the cabin, continuous pressing buttons operable with the elbow
-
Additional external control by authorized person
-
2000mm travel height if open cabin 4000mm height if full cabin
Escalators, Travellators & Mechanical Ramps
-
Moving surface gradient ≤ 5%
-
Contrast pavement with surrounding at the beginning and end of travellator
-
Marked travel direction
-
Audio system indicating start and end
School Sanitary Provisions (Public Use)
-
Public toilets for male and female provided
-
Public toilet within 150 m distance
-
Furniture have a reflectance contrast of at least 30 points LRV
-
Toilet appliances height between 900 -1200 mm
-
Toilet appliances automatically activated or operable with the elbow
-
Door clear width 900mm and comply door requirements
-
Door latches operable with the elbow installed between 900 -1200 mm
-
Coat hanger on the door from inside cabin doors in the public toilet between 1100 -1400 mm height
-
If 2 or more urinals, 1 with usable height at 300 mm and with grab bars
-
Flushing systems are operated by pressing or with a flush handle with large surface and operable with one hand or elbow, toilets and urinals
-
Distance between the urinal grab bars is 500 mm
-
Urinal Grab bars mounted between 700mm from bottom up to 1200mm height
-
In each toilet block a baby changing board is provided
-
Non slippery floor surface with Pendulum Test Value (PTV) ≥ 45
-
With wash basins in a row, 1 is accessible
-
Accessible wash basin clearance from ground surface space ≥ 700 mm high and ≥ 250 mm deep
-
Usable wash basin surface top height between 800 -850 mm
-
Faucets (water tap) operated by pressing button or a lever handle or with a sensor ( Not turning valve)
-
Distance to the faucet ( water tap) shall be less than 600 mm and vertical between 900 mm and 1200 mm.
-
Lower edge of mirror ≤ 900 mm height
-
Controls and accessories height (soap dispenser, dryer) mounted at height 700 -1200mm
-
Advisory signs indicating safety procedures and other regulatory information
Family toilet
-
One family toilet within 300 m distance from any part of the building (Separated accessible toilets outside the toilet blocks if provided with changing facilities could be considered as Family Toilet)
School Accessible Toilets
-
One accessible toilet for each gender in every floor or 1 independent accessible toilet for both genders
-
One accessible toilet within a 150 m distance from any part of the building
-
Corridors width in toilets, showers, lockers spaces of 1200 mm
-
Maneuvering turning space diameter of 1500 mm in circulations
-
Maneuvering space diameter of 1500 mm inside the toilet
-
Lateral interaction space on both sides of the toilet or on one side if symmetrical units
-
Lateral interaction space size 865mm x 1420mm
-
Door open outwards or is sliding
-
Door with horizontal 300 mm grab bar placed between 900 -1000 mm height at 300 mm from the hinge side
-
Latch operable with the elbow installed between 900 -1200 mm
-
Coat hanger between 1100 -1200 mm
Grab bars
-
The space between grab bars and the wall ≥ 45mm
-
Withstand a force of 1 kN in any direction
-
Circular diameter between 30 -40 mm
-
Horizontal bars height between 700 -750 mm. Support length of 700 mm
-
Bars mounted in the transfer space must be foldable
-
With two transfer areas, distance between both grab bars 670 mm and 700 mm
-
With one transfer area, horizontal bars mounted in wall 300 mm from the sanitary edge with 700mm length and mounted 700 -750mm
-
600mm vertical bar mounted 700 -750mm from ground away 700mm from the wall
-
Toilet height between 450 -500 mm
School Changing Rooms
-
Corridors width ≥ 1000mm and direction changes with Maneuvering turning space of 1500mm
-
Approaching space for lockers, benches and furniture 1420 x 865mm
-
1 of 10 showers is accessible, if provided
-
1 of 10 toilet is accessible, if provided
Shower Rooms
-
Shower floor surface at same floor level with surrounding area
-
Drain water slope ≤ 4%
-
Dimensions of showers area at least 865 x 1200 mm and a seat of at least 400 x 400 mm
-
Seat located at a height between 450 -500 mm and separated from the wall between 150 -200 mm
-
Horizontal bar length 800 mm mounted 700 -750 mm from the ground
-
Two Vertical bars length of 800 mm in the lateral wall of the shower seat mounted 800 mm from the floor level
-
Distance between vertical bars between 670 -700 mm
-
Controls within 500mm away from the shower seat
School Ablution Area
-
Electronic or sensor faucets
-
One accessible ablution unit linked to an accessible path. The closest from the entrance
-
Two horizontal bars mounted between 700 -800 mm with the same length of wash basin
-
All Accessories at a height between 700 -1200 mm
-
Provides bidet shower system, soap and paper
-
Approaching free space of 1200 mm
-
The approaching free space with contrast ≥ 30 points LRV
School Furniture
-
Without sharp edges, protruding objects, burning surfaces. With contrasting colour. Made with non-toxic material, and noted if causing allergy
Tables
-
Height of the top ≤ 800 mm
-
Clearance height under the table ≥ 680mm
-
Clearance depth under the table ≥ 480mm
-
Tables without integrated seats
Benches and Chairs
-
Seat height of 430 mm with a ±30 mm tolerance
-
Seat depth between 400 -450 mm
-
With backrest height between 400 -460 mm
-
Some seats with armrests
-
At least in one side has lateral interaction space for wheelchair min 865 x 1420mm with international symbol
-
Outdoor spaces -benches every 100 meters accompanied with shaded areas every 50 m In buildings -benches or seat types every 50 meters
-
Seats with different characteristics to suit different students needs: 1-removable seats to provide places for wheel chairs 2-handed desks to suit left handed users 3-duble seats for students of big body shapes 4-seats with communication accessories if needed 5-seats with breathing accessories if needed 6-seats provided or served by electricity plugs if needed without obstructing the corridors by cable
Drinking fountains, if provided
-
Two fountains with different heights ≤ 915mm for the lower one with leg clearance
-
Comfortable frontal and lateral approach
-
If manual button, minimum height = 700mm for the lower one and maximum 1200mm for the higher one
-
Water supply between 600 -900mm height
-
Provided with bottle filler
-
Clearly visible with contrasting background
Trash bins
-
Not located in the accessible path
-
Lateral space of interaction of at least 865 x 1420mm
-
Trash bin opening height ≤ 900 mm
-
Trash bins every 50 meters
-
When fixed to the walls protrude ≤ 250 mm
-
Operable with an elbow if opening mechanism is provided
-
Operable with an elbow if opening mechanism is provided
-
Well contrasted signage
Vending Machines and ATM's (if provided)
-
One frontal or lateral interaction space 865 -1420mm
-
Floor surface is smooth, non-slippery with a gradient ≤ 2%
-
Screen and keyboard are visible from a point located 1000 mm above the floor
-
Screen and keyboard with no reflection or glare
-
Control buttons height between 400 -1200 mm and ≥ 600 mm from any corner
-
Control buttons with high embossed text and Braille
-
Card slot height between 800 -1200 mm
-
Visual and acoustic indication system and alarm system provided
-
Audio information provided
-
CCTV Intercom provided
-
Slots are wide and have a funnel effect
Bollards, planters, telephone booths and other furniture elements, if provided
-
Outside the accessible path or do not reduce accessible path ≤ 1200mm
Parking and drop off point
-
Pick up & drop off area provided
Accessible parking places, access to parking lots
-
Number of accessible parking lots, if parking facilities provided:2 % of the total number of parking spots. Maximum 10 spots A partial parking to be considered as a full parking at the maximum number of 10 parking If parking facilities not provided: 2 bays in public areas close to the entrance
-
Accessible spaces as close as possible to the entrance of the building and no more than 50 m
-
Dimensions of accessible parking spaces: 2500 x5500 mm for angled parking, 2600 x 6000 mm for parking along the sidewalk
-
With lateral access aisle ≥ 1200 mm
-
Signs mounted at 2200 mm with international symbol
-
Marked with international symbols
-
Curb cut with maximum 8% slope
Accessible Room
Rooms
-
Clear route for wheelchair movement
-
Illumination ≥ 200 lux
-
Controls placed at height between 700 -1200 mm
-
Electronic outlets at height between 400 -1000mm
-
Acoustic and visual fire alarm provided
-
Shelves and drawers are provided between 700 -1200mm from the floor and clothes hanger placed at height 1200mm
Dining rooms
-
Accessible path of travel provided to half of dining area (900mm minimum)
-
Illumination ≥ 100 lux provided in at least 10% of dining rooms
-
Sound reduction materials used in dining rooms, floors and walls made of washable materials
-
10% of the tables shall comply with the dimensional criteria for tables
-
The self service tables height located between 900 -1200mm from the floor
-
Minimum 900mm clear passage to all food service area
-
Spaces for children strollers and mobility devices are provided, 10 % of seats are movable
Auditorium, Sport stadium, theater
-
Number of reserved seats: one reserved wheelchair space for every 50 seats or fraction thereof and beyond 500 seats, one more every 100 seats of fraction thereof , as on general chicklist GAU
Auditorium seating spaces
-
Connected to accessible path, and accessible seating places are permanently provided or removable seats
-
Dimension of wheelchair seating space 865 x 1420 mm if frontally approached or 865 x 1500mm if laterally approached
-
With Maneuvering level space of 1500 x 1500mm
-
With international symbol of access (ISA)
-
Maximum longitudinal gradient 1% for wheelchair and Maneuvering space
-
Wheelchair spaces are arranged into groups of two spaces with equal numbers of fixed seats in every group row
-
Number of reserved seats: one reserved wheelchair space for every 50 seats or fraction thereof and beyond 500 seats, one more every 100 seats of fraction thereof
-
Clearly visible space for sign language interpreter with overhead light
-
Designated accessible seats for people with hearing impairments in front of the sign language interpreter
-
Aisle seats and its adjacent have foldable armrests
-
Some seats have spaces to serve pets
Stage and backstage
-
Stage is accessible via ramp or lift
-
Accessible backstage for capacities ≥ 100 spectators
Hearing Enhancement
Induction loop, FM, infrared (through expert advice)
-
Hearing enhancement system is provided in the service counters and assembly areas
-
Hearing enhancement system is provided in the meeting rooms serving more than 25 person
-
Hearing enhancement system provided in the auditoriums and theaters
-
Posted sign to indicate that the enhancement system is available
-
Compatible with language translation system
-
International symbol of access for hearing loss is provided, when the system is provided for persons with hearing impairment
General
School Doors
-
Have a free passage width ≥ 900 mm
-
900-1200mm handle of opening mechanism height and operable by elbow or automatic
-
40mm free gap minimum between lever (handle) and the door surface
-
No round knobs
-
Sliding doors with vertical fixed opening bars
-
Force to open the door ≤ 25 N
-
Swinging door open 90°
-
Door stoppers provided
-
250mm height kick plate provided to doors in high use areas
-
Alternative door provided when there is a revolving door
-
Dimensions of Maneuvering spaces / one way swinging door comply: On pull side –600 mm space adjacent to the leading edge and 1500 x 1500 mm space On push side –300 mm space adjacent to the leading edge and 1200 x 1200 mm space
-
Dimensions of Maneuvering spaces comply: Sliding doors –300 mm space adjacent to the leading edge and 1200 x 1200 mm space
-
Dimension of maneuvering spaces comply: Both side swinging door -300mm space adjacent to the leading edge both sides, and minimum clear floor space of 1200mm x 1200mm both sides
-
Clear spaces without obstructions of other doors
-
If two aligned doors in a series -minimum space of 1200mm x 1200mm clear between them
-
If two angled doors in a series -minimum space of 1200mm x1500mm clear between them
School Windows
-
Without projections ≤ 2200 mm into the pedestrian area
-
Opening mechanisms not require wrist turning
-
Fixed glazing at maximum of 900 mm height
-
Operable window at 1200 mm height
-
With guardrails if window opening < 1200 mm
School Switches
-
Located between 900 –1200 mm height and located ≥ 600 mm from any corner
-
Switch plates with contrast of 30 LRV against its background
-
Switches can be activated with the elbow
School Glass Surfaces more than 500mm width or 850mm height
-
Glazed surfaces are identified clearly from adjacent doors or other openings
-
Presence of two horizontal bands of 100mm width with color of 50 LRV or any other pattern or design occupy 50% of the area between 850 -1600mm, without empty space bigger than 500mm wide
-
First horizontal band height between 1400 -1600mm from the ground level Second horizontal band height between 850 -1000mm from ground level
Mailboxes, parking meters, garbage and recycling containers and restaurant terraces
-
With frontal or lateral interaction space 865 x 1420mm
-
Interaction mechanisms height between 700 -1200 mm
-
At least one garbage container can be opened with one hand and force < 25 N
Restaurant terraces
-
No invading accessible path and headroom
-
No interruption of guidance elements
-
Protected by continuous element unless all features height ≥ 900mm
-
Accessible path ≥ 2000mm adjacent to the restaurant terraces
-
Bollards between terraces and road every 1200 mm
Bus shelters
-
Not invading accessible path
-
With a free of protruding obstacles path in both sides of at least 1200 mm width
-
Maneuvering space ≥ 1500 mm diameter inside the shelter
-
Height ≥ 2200 mm
-
No obstacles between shelter and access to bus
-
Glazed walls with indication and warning marks, if provided
-
With fixed bench + seat height 400 -460mm, depth from 400 -450mm, backrest ≥ 400mm
-
With armrest on one of its side
-
With standing support (perch seat) of height between 700 -750 mm and separated ≥ 200 mm from wall
-
Average illumination ≥ 50 lux, and ≥ 100 lux at boarding time
-
Boarding area platform with tactile warning surface
Bus signpost
-
Sign post provided
-
Not obstructing the accessible path
-
Clearance height ≥ 2200mm without protruding
-
Bus information height between 1200 -1600mm
-
Bus line identification number with text height ≥ 140 mm
School Alarms and means of Egress
-
Audio and visual emergency alarms provided
-
Visual Emergency alarm with 30 flashes per second
-
Accessible means of egress signage
-
Located at places where all occupants can see, including toilets and bathrooms
-
Procedures for evacuation building including procedures for persons with activity limitation are posted
-
Procedures posted in 14 ptSan serif font
-
Other evacuation solutions for persons with activity limitation with assistance of an evacuation devices including protected elevator or chair
-
Evacuation devices or chair are provided in every floor located near the evacuation stairwell
-
Fire personnal and persons with activity limitation are trained to use evacuation devices
School Facilities
Storage and Lockers
-
Approaching space 1420 x 865mm
-
Corridor width ≥ 1000mm
-
Maneuvering turning space 1500mm
-
20% of shelves or lockers are in a reaching height distance between 600 -1200 mm
First aid facilities
-
With an accessible door and path to the treatment area
-
With adult changing table
Gender equality
-
In case of segregated use by gender, same level of accessibility for both genders
School Swimming Pools
-
With accessible entrance, chair lift, ramp or hoist
-
With safety ladder
-
With underwater illumination if night use is foreseen
-
With depth scale sign according to font size and reading distance standards
-
Pendulum test value ≥ 45 of the floor surface of the swimming pool area
School Wayfinding
-
All parks entrances shall display a visual and tactile map of the main facilities, displaying the North symbol at the top of the map with oral information, if required
-
Tactile maps in required buildings
-
Dimension of the tactile map ≤ 800 x 450mm and the font size > 20mm San serif type
-
The height of tactile map horizontal or inclined from the floor 900-1200mm and the inclination between 30∘to 45∘
-
If fixed vertically, located between 1250 -1750mm
-
The location of the tactile map on the right side near the door within 1000mm and near the stair or elevator in the multistory building
-
All public buildings have the name and Makani number on façade and directory inside the lobby
-
All door frames with information signs in public buildings
-
In buildings, orientation signs every 30 meters, including exit and toilets and other services
-
In parks and open spaces orientation sign every 70 meters for nearest exit and nearest toilets
-
Letters, numbers, symbols and pictographs are not glare and high reflectance contrast
-
Includes both Arabic and English languages
-
Directional signsare simple, clearly visible, good shape and well organized with no duplicated information and with reflectance contrast ≥ 50 LRV
-
Braille character located at the bottom left of the distination sign at distance of 10 -30mm, according to ISO 7000 : 2004 standards
-
Pictograms and symbols follow ISO 7000 : 2004 standards
-
Symbol height ≥ 30mm and thickness 2 -5mm for letters and 2mm for symbols
-
Signs at walls located at height 1200 -1600mm on the left side of the door
-
Exit and evacuation pictogram according to ISO 3864 -1 : 2002
-
Digital screens located at height 1700-2000mm, with slight inclination (15∘-30∘) and visible from a minimum distance of 1000mm
-
Signs font size according to reading distance:<br><br>Reading distance ≥50 meters, font size = minimum 170 mm to 200 mm<br>Reading distance 20 meters, font size = Minimum140 mm to180 mm<br>Reading distance 5 meters, font size = minimum 70 mm to 140 mm<br>Reading distance 4 meters, font size = minimum 56 mm to 110 mm<br>Reading distance 3 meters, font size = minimum 42 mm to 84 mm<br>Reading distance 2 meters, font size = minimum 28 mm to 56 mm<br>Reading distance 1 meter, font size = minimum 14 mm to 28 mm<br>Reading distance 0.5 meters, font size = minimum 7 mm to 14 mm
-
Signs out of the accessible path and clear headroom ≥ 2200 mm
-
In addition to visual communiction channel, acoustic or tactile should be provided
-
Guiding tactile pavements in: -Open squares without defined walking paths -Metro, tramway and ferry networks