Title Page

  • Conducted on

  • Prepared by

  • Location
  • Empty ice storage bin

  • Disconnect unit from electrical supply

  • Close off water supply

  • Remove Dispense spout & ‘sink’ tray and clean as appropriate then soak in a sanitizing solution until required later in the process.<br><br>

  • Remove Top, left & right panels.<br><br>

  • Remove front fascia panel & inspect Pushbuttons for any restrictive operation/ check contact block electrical connections – Fit or replace ‘Membrane Boot’ on each pushbutton as required.<br><br>

  • Clean Condenser grills & inside machine area<br><br>

  • Drain Water System at lowest point, reconnecting hose when emptied<br><br>

  • Using the appropriate PPE (Gloves, specs etc):

  • Prepare De-scale solution at a 10% ratio<br><br>

  • Refill water inlet tank with De-scale solution<br><br>

  • Let the water system soak for 10 minutes<br><br>

  • Run the machine for 5 minutes with solution being manually topped up during this time<br><br>(Note – to operate machine, the water sensor circuit will have to be bridged and the lid switch over-ridden, jump the 2 pins on the pcb to over ride 3 minute standby)<br><br>

  • Drain de-scale solution from system<br><br>

  • Rinse water system through, thoroughly with fresh water<br><br>

  • <br>Inspect internal water distribution hoses, replace as appropriate if discoloured<br><br>

  • NOTE - DO NOT MIX THE TWO SOLUTIONS !!

  • Prepare Sanitizer solution at a 10% ratio<br><br>

  • Refill water inlet tank with Sanitizer solution<br><br>

  • Let the water system soak for 10 minutes<br><br>

  • Run the machine for 5 minutes with solution being manually topped up during this time<br><br>(Note – to operate machine, the water sensor circuit will have to be bridged and the lid switch over-ridden, jump the 2 pins on the pcb to over ride 3 minute standby)<br><br>

  • Drain Sanitizer solution from system<br><br>

  • Rinse water system through, thoroughly with fresh water<br><br>

  • Remote ‘Vane’ motor, storage bin cover & conical plate from inside the bin<br><br>

  • Wash out the storage bin with sanitizer, check condensate drain point of bin is clear<br><br>

  • Clean storage bin cover & ice level control lenses & spout area <br><br>

  • Clean around ice dispense area (‘Polo’) & base of storage bin<br><br>

  • Re-assemble Storage bin, Vane Motor and spout covers<br><br>

  • Re-assemble all external panels of unit and wipe down. Test pushbutton for correct operation !<br><br>

  • Check & replace drain hose with 20mm ID smooth bore if ridged version fitted<br><br>

  • Clear drain off point under glass ‘sink tray’ with warm soapy water and bottle brush<br><br>

  • Refit dispense spout and ‘sink’ tray.<br><br>

  • Change the water filter cartridge (if a filtration unit is installed to the water supply)<br><br>

  • Run unit for 15 minute’s discard the ice produced purely as a precaution.<br><br>

  • Customer signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.