2 Handover & Collateral Delivered to Chorus

  • 2.02 Plant Damage Report (PDR) form completed

4 Codes

  • 4.001 Correct TFD code used (888 used for customer chargeable fault)

  • 4.002 Correct CSE code used

  • 4.003 Correct ACT codew used

  • 4.004 Correct Statement of Work codes used

5 Fault

  • 5.001 NTS test result (Good Line)

  • 5.002 Records - Customer information & cable pairs correct, changes updated

  • 5.003 Any Pair change meets current rules

  • 5.004 OUT Fault Ticket text field completed - first name, surname initial, fault cause, fault resolution, location of repair incl. street no., name of end customer if contacted. If applicable: reason for uneconomic repair, billing information – S&S doc no., PDR no., NFF – NVF no.

  • 5.005 First Time Fix principles applied. Fault repaired but there was another service affecting issue that could have been fixed and wasn’t.

  • 5.008 Proactive opportunities identified

  • 5.009 Escalation procedure followed (Defect Referral)

9 MDF (7535, NDF-100A, NDF-100B, ND0066)

  • 9.001 MDF Block secure (installation, earthing)

  • 9.002 MDF Block Labelling correct (Cable Number, Pair range)

  • 9.003 MDF Area cable entry duct sealed

  • 9.005 Jumper routing via frame guides

  • 9.006 Jumper type correct (OR/WH) with required (175mm - 225mm) slack left

  • 9.007 IDC jumper terminations correct (full insertion to IDC, excess trimmed)

  • 9.008 Solder jumper terminations correct (wire strip & wrap, no excess solder)

  • 9.009 Old jumpers removed

  • 9.01 Lightning protection (where fitted) earth to common earth

  • 9.011 Cable pair records updated

  • 9.012 Sign off codes correct (specify here)

  • 9.013 Site tidy, rubbish bins, jumpers, floor

10 Pride & Logs

  • 10.002 MDF Log completed in exchange

20 Copper Cable Jointing

  • 20.002 Cable at correct depth & sheath free from damage

  • 20.004 Cable excess length sufficient

  • 20.005 Correct jointing connectors & tool used

  • 20.008 No obstruction of spare ducts

  • 20.010 Site tidy, no waste, ground reinstatement completed.

21 Copper Heat shrink Closure (incl PEDCAP & Radi)

  • 21.001 Closure sized correct

  • 21.002 Cable entry prepared; Clean, Abrade, Flame Brush, alu foil

  • 21.003 Cable position at entry correct; largest on top

  • 21.004 Branch Clip or SCOP use correct

  • 21.005 Thermal colour change even, white line visible down SS channel

  • 21.006 Sufficient glue extruding at ends

  • 21.008 Closure management; manhole arms or direct buried has protective slab

  • 24.001 SSA cable binding to hardware correct

  • 24.002 SSA cable erected correctly

  • 24.003 SSA cable type and size correct

  • 24.006 SSA tension & sag & twist (anti dancing) correct

25 Poles

  • 25.003 Pole in good condition, no splits, burs

  • 25.004 Pole manufacture label in place, Pole strength minimum 6kn

  • 25.005 Pole hole depth correct/Pole vertical and height correct

  • 25.006 Pole positioning and spacing correct, correct face position

  • 25.007 All new poles have Network pole tag installed 3mtr above ground

  • 25.01 Pole safe to climb (hammer/probe/dig)

  • 25.011 All metal plant hot dipped galvanised & CNSP approved

  • 25.012 Plant positioned correctly and safely, plant clearances correct

  • 25.02 Network labelling (eg cable terminal, joint label, 124 sign) in place to suit requirements

  • 25.021 Site tidy, no task waste, ground reinstatement completed

26 Cable Markout

  • 26.021 Plant Damage reports: Damage repaired

  • 26.022 Plant Damage reports: Report signed by service company Field Manager

31 Active Cabinet Internal RHS

  • 31.002 Door stays are in place and all work well

  • 31.004 Soft foam seal plate secured. Cable entry prevents vermin/insect entry.

  • 31.006 MDF; Correct Modules installed

  • 31.007 MDF; Module Labelling correct

  • 31.008 MDF; Data card for jumper running data (laminated or in a card holder attached to the inside of door)

  • 31.009 MDF; Cabinet E-side Termination data card in door.

  • 31.01 MDF; Jumper correct type (BL/WH)

  • 31.011 MDF; Jumper run correctly (50mm slack & no excess)

  • 31.016 Bottom LHS Earth bar strapped to each MDF vertical and the base of the cabinet

37 Passive Copper Cabinet

  • 37.001 Outer Door lock works smoothly and door closes without jamming

  • 37.002 Door stays are in place and all work well

  • 37.003 Cabling run correctly

  • 37.004 Distribution Frame: Correct Modules installed

  • 37.005 Distribution Frame: Module Labelling correct

  • 37.006 Distribution Frame: Data card (laminated or in a card holder attached to the inside of CCC door)

  • 37.007 Distribution Frame: Cabinet Laminated E-side Termination data card in door.

  • 37.008 MDF; Jumper correct type (BL/WH)

  • 37.009 MDF; Jumper run correctly (50mm slack & no excess)

  • 37.01 MDF: All dead jumpers removed

  • 37.011 Module support bars, separators and cover in place

  • 37.013 Lightning protection installed (when specified) or reinstated after testing

  • 37.014 All duct seals in place

  • 37.015 Concrete around ducts in base of cabinet

  • 37.016 Locks & hinges OK

  • 37.017 Door seals in good condition

  • 37.018 Excess vegetation removed

39 Aerial Terminal

  • 39.001 Correct terminal used

  • 39.002 Terminal mounted and secured correctly

  • 39.004 Terminal lid secure

  • 39.005 Terminal label on lid or plate on pole

  • 39.006 Lead-in entry correct

  • 39.007 Lead-in terminated correctly

  • 39.009 Cable shield installed

40 Pillar Terminal

  • 40.001 Pillar - vertical, firm, depth

  • 40.002 Pillar ID correct

  • 40.003 Lid secure

  • 40.004 Lead-in thru base only

  • 40.005 Plastic bags installed & secure

  • 40.006 Foam bung fitted

  • 40.007 Minimum sheath height 50mm (30mm if in concrete and/or uneconomic to repair, 80mm for V3)

  • 40.008 Coloured zip ties to 25 pair groups (not too tight)

  • 40.009 Correct cable used

  • 40.01 Correct connectors used

  • 40.011 Circuit dedicated

  • 40.012 Service Lead labelled correctly

  • 40.013 Unused pairs capped

  • 40.014 Damaged conductors repaired

  • 40.015 Faulty connectors replaced

  • 40.016 Encapsulated loop resealed correctly

  • 40.017 V3: Lead-in customer and network labels OK

  • 40.018 Green cable tie on exchange side

  • 40.019 Service Lead - flying leads installed and correct

  • 40.020 Unused pairs connected through

  • 40.021 Connectors >50mm from ring cut

  • 40.022 Site tidy, no task waste.

41 BDD Terminal

  • 41.001 Pit lids secure/locked, with bung fitted where appropriate

  • 41.002 Pit installed correctly

  • 41.003 Radi: Base & lid clean, O ring seated correctly, O ring replaced upon entry

  • 41.004 O/J lid labelled

  • 41.005 Radi is correctly installed, thermal change and lead in

  • 41.006 2m loops at BDD pits

  • 41.007 2m insulated tail installed at last BDD

  • 41.008 Plastic bags installed & secure

  • 41.009 Coloured ties to 25 pair groups

  • 41.01 Correct cable used

  • 41.011 Correct connectors used

  • 41.012 Circuit dedicated

  • 41.013 Service Lead labelled correctly

  • 41.014 Unused pairs capped

  • 41.015 Damaged conductors repaired

  • 41.016 Faulty connectors replaced

  • 41.023 Site tidy, no task waste

42 PDS Terminal

  • 42.001 Pedestal - vertical, firm, depth

  • 42.002 Correct size pedestal used

  • 42.003 Lid secure

  • 42.004 PDS network labelled correctly

  • 42.005 Designed pair arrangement correct

  • 42.006 QF terminal labelling correct

  • 42.007 QF terminal secured to backing plate

  • 42.008 Foam bung fitted

  • 42.009 Adequate gel in quiet front

  • 42.01 Service Leads installed correctly

  • 42.011 Service Lead labelled correctly

43 Aerial Service Lead

  • 43.001 Correct Service Lead used

  • 43.002 No In span joints

  • 43.003 Tension, sag and twist correct

  • 43.004 Correct pole fittings used and installed (screw eyes, sash clamps)

  • 43.005 Lead-ins enter terminal correctly

  • 43.006 White pipe down poles

  • 43.007 600mm saddle spacing or 1500mm bandit spacing

  • 43.008 Roadway crossing min 5.5m height, elsewhere 4.25 metre height

  • 43.009 Loops on poles tied

  • 43.012 Correct building fittings used (screw eyes, sash clamps)

  • 43.015 Site tidy, no task waste

44 Buried Service Lead

  • 44.001 Service Lead terminated correctly

  • 44.002 20mm pipe connected at Pedestal correctly - (bend into pedestal)

  • 44.003 20mm pipe connected at BDD correctly (50mm into BDD pit, 450mm deep)

  • 44.004 20mm pipe connected at RLG correctly (at base of DP, bend if room)

  • 44.005 Individual pipe & cable for installs of <100 metre

  • 44.006 Direct buried cable option (no pipe) for > 100 metre

  • 44.007 Green 20mm installed in trench

  • 44.008 White pipe above ground level

  • 44.009 Depth correct (450mm cover)

  • 44.01 Power/ Gas clearances correct

  • 44.011 Cable & pipe repair correct

  • 44.012 Reinstatement/ backfill satisfactory

  • 44.013 Pipe connected at ETP correctly (not glued)

  • 44.014 Overlay of Service Lead justified

45 ETP

  • 45.001 ETP physical alignment correct, all fittings secure, installation tidy

  • 45.002 ETP location: (buried lead in-300-1500mm) (AE lead in on facia/under eaves)

  • 45.004 Aerial lead in to ETP correct eg termination hardware, position, tidy appearance

  • 45.005 20mm pipe to ETP is white only

  • 45.006 20mm pipe end (within ETP) is sealed with silicone and drainage holes left clear

  • 45.007 Premise cabling exit via back of ETP

  • 45.008 Premise cabling exit from ETP is sealed with silicone

  • 45.009 All connections via gel filled connectors

51 Open Aerial

  • 51.002 Poles tested, firm & secure

  • 51.003 Aerial wires regulated correctly

53 TNT/TNF (Building Frames)

  • 53.001 TNF or TNT installed correctly

  • 53.002 Disconnection block installed correctly

  • 53.003 Earthing requirements met

  • 53.004 Demarcation point installed correctly

  • 53.005 TNF/TNT Labelled correctly

  • 53.006 TNT/TNF additional warning label installed NDF-151

  • 53.007 Jumper routing via frame guides

55 Network Records

  • 55.085 FRE generated to capture faults (where appropriate)

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.