Title Page

  • Site conducted

  • Audit Title

  • Project Name

  • Conducted on

  • Prepared by

  • Location
  • Instructions
    -------------------
    1. Answer "Checked" or "Hold" for the questions below, then identify the personnel who conducted the checking.
    2. Add photos and notes by clicking on the paperclip icon.
    3. To add a Corrective Measure click on the paperclip icon, then "Add Action", provide a description, assign to a member, set priority and due date.
    4. Complete audit by providing digital signature.
    5. Share your report by exporting as PDF, Word, Excel or Web Link

GRC

  • Main Contractor:

  • Project Number:

  • Issued to:

  • QA Sheet No:

  • Elevation:

  • Level:

  • Comments:

STRUCTURE and preceding trades

  • SFS support and siniat Board complete.

  • Personnel

Tyvek Firecurb Membrane

  • Correct membrane installed and sealed using the correct tape.

  • Personnel

  • Tears, splits or holes repaired and fully taped min 100mm overlap.

  • Personnel

Support Grid

  • Flat plate fire barrier is correctly installed to window jambs. Flat plates fixed at 600mm centres with JT3 3 63 x 50 without washers. Gaps sealed between window jamb and flat plate with rockwool fire pro intumescent mastic.

  • Personnel

  • Vertical GRC support brackets to PFC's installed as per A2O working drawings. Isolation pad behind bracket and fixings as per schedule (Stainless steel mola bolt peg anchor).

  • Personnel

  • Horizontal GRC brackets to concrete installed as per A2O working drawings. Isolation pad behind bracket and fixings as per schedule (M12 fischer bolts tightened to correct torque setting).

  • Personnel

  • Fire barriers installed as per drawing and QA sheets recorded on Bolster.

  • Personnel

Rockwool Insulation

  • Insulation fixed in accordance with A2O working drawings.

  • Personnel

  • Insulation joints and penetrations around brackets need to be butted tight with no gaps.

  • Personnel

GRC pieces

  • GRC pieces installed in correct order as per SCI working drawings.

  • Personnel

  • GRC pieces lined and levelled using adjustment on brackets / stainless steel packers as per GB architectural specification.

  • Personnel

  • GRC pieces checked for chips / blemishes. Any holes filled with GRC repair compound as per GB architectural recommendations.

  • Personnel

  • Elevation photos

Completion

  • Installer Signature:

  • A2O Signature:

  • Client Signature:

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.