Title Page
-
Site conducted
-
Audit Title
-
Project Name
-
Conducted on
-
Prepared by
-
Location
-
Instructions
-------------------
1. Answer "Checked" or "Hold" for the questions below, then identify the personnel who conducted the checking.
2. Add photos and notes by clicking on the paperclip icon.
3. To add a Corrective Measure click on the paperclip icon, then "Add Action", provide a description, assign to a member, set priority and due date.
4. Complete audit by providing digital signature.
5. Share your report by exporting as PDF, Word, Excel or Web Link
Kingspan FL
-
Main Contractor:
-
Project Number:
-
Issued to:
-
QA Sheet No:
-
Elevation:
-
Level:
-
Comments:
Metsec Framing
-
Metsec stud positions correct, lined and levelled within tolerance.
-
Personnel
- Installer
- A2O
-
Membrane installed.<br>
-
Personnel
- Installer
- A2O
Seals
-
Base support cleats installed in accordance with A2O drawings <br>
-
Personnel
- Installer
- A2O
-
Gaskets and seals installed in accordance with A2O drawings.<br><br>
-
Personnel
- Installer
- A2O
Panels
-
Check that panels are un-damaged as they are removed from pallets and that there is no significant colour variation. <br>
-
Personnel
-
Check panels are properly engaged into each other and horizontal joints aligned with adjacent panels. <br><br>
-
Personnel
- Installer
- A2O
-
Panels fixed to studs at head in accordance with A2O drawings. <br><br>
-
Personnel
- Installer
- A2O
-
Protective film to be removed from panel faces prior to installation (unless instructed otherwise by client). <br>
-
Personnel
- Installer
- A2O
-
All vertical gaps between panel joints to be fully packed with either loose rockwool (min 23kg/m3 density) or fire rated canister grade foam.<br>
-
Personnel
- Installer
- A2O
Flashings/Joint Gaskets
-
Vertical recessed top hat and insert installed in accordance with A2O drawings.<br><br>
-
Personnel
- Installer
- A2O
-
9x3mm continuous butyl tape applied behind any face fix flashings. <br>
-
Personnel
- Installer
- A2O
-
Profiled butt straps present at flashing joints. <br>
-
Personnel
- Installer
- A2O
Completion
-
Installer Signature:
-
A2O Signature:
-
Client Signature: