Kingspan Louvre Panel onto SFS
-
Main Contractor:
-
Project Number:
-
Issued to:
-
QA Sheet No:
-
Elevation:
-
Level:
-
Comments:
STRUCTURE
-
Mestec QA complete for area of work.
-
Personnel
- Installer
- A2O
Seals/Gaskets/Bearers
-
Base support cleats/channel installed in accordance with A2O drawings <br>
-
Personnel
- Installer
- A2O
-
Gaskets and seals installed in accordance with A2O drawings <br>
-
Personnel
- Installer
- A2O
Panels
-
Check that panels are un-damaged as they are removed from pallets and that there is no sigificant colour variation. <br><br>
-
Personnel
- Installer
- A2O
-
Check panels are properly engaged into each other and horizontal joints aligned with adjacent panels. <br><br>
-
Personnel
- Installer
- A2O
-
Panels fixed to studs at head in accordance with A2O drawings. <br><br>
-
Personnel
- Installer
- A2O
-
Protective film to be removed from panel faces prior to installation (unless instructed otherwise by client). <br>
-
Personnel
- Installer
- A2O
-
All vertical gaps between panel joints to be fully packed with either loose rockwool (min 23kg/m3 density) or PIR infill. Vertical joints to be 20mm. <br>
-
Personnel
- Installer
- A2O
Flashings/Joint Gaskets
-
Top hat vertical joint flashing installed into vertical joint in accordance with A2O drawings. <br><br>
-
Personnel
- Installer
- A2O
-
Profiled filler blocks installed to sides of joint.
-
Personnel
-
9x3mm continuous butyl tape applied behind any face fix flashings. <br>
-
Personnel
- Installer
- A2O
-
Profiled butt straps present at flashing joints. <br>
-
Personnel
- Installer
- A2O
Completion
-
Installer Signature:
-
A2O Signature:
-
Client Signature: