Title Page

  • Site conducted

  • Audit Title

  • Project Name

  • Conducted on

  • Prepared by

  • Location
  • Instructions
    -------------------
    1. Answer "Checked" or "Hold" for the questions below, then identify the personnel who conducted the checking.
    2. Add photos and notes by clicking on the paperclip icon.
    3. To add a Corrective Measure click on the paperclip icon, then "Add Action", provide a description, assign to a member, set priority and due date.
    4. Complete audit by providing digital signature.
    5. Share your report by exporting as PDF, Word, Excel or Web Link

Mech-Slip Rainscreen

  • Main Contractor:

  • Project Number:

  • Issued to:

  • QA Sheet No:

  • Elevation:

  • Level:

  • Comments:

STRUCTURE and preceding trades

  • SFS support and Versapanel Board complete.

  • Personnel

  • EPDM installed correctly.

  • Personnel

Tyvek Firecurb Membrane

  • Correct membrane installed and sealed using the correct tape.

  • Personnel

  • Tears, splits or holes repaired and fully taped min 100mm overlap.

  • Personnel

Support Grid

  • Fixed and sliding point brackets spaced vertically/horizontally and fixing arrangement in accordance with working drawings using stainless steel tek fixings.

  • Personnel

  • Vertical T and L rails positively fixed to fixed point brackets using stainless steel rivet/tek fixings.

  • Personnel

  • Vertical T and L rails fixed to sliding point brackets through slotted holes to facilitate movement.

  • Personnel

  • Horizontal movement joint included at slab level.

  • Personnel

Rockwool Insulation

  • Insulation fixed in accordance with A2O working drawings.

  • Personnel

  • Insulation joints and penetrations around brackets need to be butted tight with no gaps.

  • Personnel

Mech Slip Brick Slips

  • Horizontal support rails installed as manufacturers details, check the correct fixings have been used.

  • Personnel

  • Bricks fully clipped into rails and spacers installed to stop mortar from falling behind the bricks.

  • Personnel

  • Check for cracked and misshaped bricks.

  • Personnel

  • Vertical coursing plumb and consistent.

  • Personnel

Completion

  • Installer Signature:

  • A2O Signature:

  • Client Signature:

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.