Title Page
-
Site conducted
-
Conducted on
-
Location
-
Site Manager
Documentation
-
Have all Project Safety Plans (CPP, TMP, ERP, EMP, QP) been Communicated, Signed by all employees and displayed?
-
Is the Emergency Response Plan site specific, readily available, placed in a prominent & easy to access location for employees to reference?
-
Has the nearest Hospital been identified and its details provided (Map, Directions, Postcode, etc.)?
-
Is the Environmental Management Plan site specific, readily available, placed in a prominent & easy to access location for employees to reference?
-
Has a Fire Risk Assessment been completed (Reviewed Monthly), Signed by all employees and displayed in a prominent location?
-
Are RAMs available for all work activities (e.g. Site Set-Up, Bund Demo) being completed on site, communicated to all employees and available for reference?
-
Is there COSHH Assessments and Safety Data Sheets available for all Hazardous Substances?
-
Has a First Aid needs assessment been completed for the project?
-
Are First Aiders contact details displayed in Site Office/Canteen?
-
Has a Daily Co-ordination Meeting held and recorded?
-
Has a Point of Work Risk Assessment (POWRA) been completed prior to work activities beginning?
-
Are High Risk activates such as Hot Works, or Excavations controlled under a Permit To Work System?
-
Has the Site Manager completed a Weekly Site Inspection?
-
Is the Site Induction site specific, is there Induction Register and copies of individuals induction forms available?
-
Has copies of everyone's SPEN authorisation been taken, ensuring no unauthorised persons can enter the site?
-
Have Safety Observation Reports (SORs) Posters been displayed (Allowing anonymous Reporting of Safety Concerns)?
Site Conditions
-
Is there a suitable number of First Aid Kit and an Eye Wash Stations available?
-
Has the site compound been located a safe distance from workplace hazards?
-
Is there Fire Extinguishers available in Welfare Facilities?
-
Has a Designated Smoking Area been identified?
-
Is the housekeeping of the site acceptable?
-
Is the site Compound secured to protect from unauthorised access, suitable perimeter fencing erected with signage (Construction Site, Keep Out) displayed?
-
Is there a Hazard Board displayed in a suitable location warning all persons of Site Hazards?
-
Is there a Safe Access/Egress Route identified (Red cones (up to 10m apart) with a Orange Rope 10mm) on the high side of the yellow cross arm (Higher side of cross arm defines the safe side)?
-
Is the Safe Working Area identified (Red cones (up to 7m apart) with two Orange ropes 10mm on each side of Yellow cross Arms, Cross Arms raised to define the safe side and Green Cones (up to to 6M apart) on the safe side?
-
Is there adequate Site Supervision for the number of Site Workers?
-
Is there suitable Danger Notices, Markers and Signage defining safe areas and those which are not?
-
Site Security, have checks be completed by the Authorised Key Holder with Substation buildings and surrounding compound. Fencing undamaged with 'Danger of Death' Signage displayed?
-
Are barriers being used to segregate workers/pedestrians from excavations and/or other work areas?
-
Is there suitable segregation of pedestrians and Plant/Vehicle movements?
-
Is Plant/Vehicle manoeuvres compliant with the Traffic Management Plan (TMP), Speed restrictions, Direction, etc?
-
Are all drivers wearing seatbelts where mandatory, Flashing Beacons turned 'On', Keys removed and secured when not in use?
Electrical Emergency Prevention & Mitigation
-
Has Heras Fencing been kept a minimum distance of 2 meters away from the Substation Palisade fencing to prevent possible Impress voltage (Chapter 8 barriers to be used next to Palisade fencing)?
-
Has Field Equipment Earthing applied to all mobile Plant or constructed access equipment to protect against Induced or Impressed voltages?
-
Are Safety Distances for Plant/MEWP's etc, being adhered to (33kV - 2.75M, 66kV - 3M, 132kV - 3.4M, 275kV - 4.6M, 400kV - 5.5M)?
-
Are all Vehicles/Plant over 2.3M, movements personally supervised by an Authorised Person?
-
Is all electrical tools and equipment 110V (No 240V electrical equipment allowed on site)?
-
Are all extension cables free from damage and positioned, so not present a trip hazard?
-
Are Cable Avoidance Tools (CAT) and Signal Generator available and being used to track the position of underground services?
-
Are 'Long Objects', any items capable of breeching the minimum safe distances of various Voltage levels, constructed of a Non-conductive material, stored appropriately and transported through the site at waist height to prevent contact with live surroundings?
-
Are hand tools constructed from Non-conductive materials (Spirit Levels, Straight Edges and Measuring tools)
Fire Emergency Prevention & Mitigation
-
Is there a suitable number of Fire Extinguishers available at relevant areas, Welfare Facilities, Refuelling area, Hot Works Activities, Designated Smoking area, etc.)?
-
Have Fire Extinguishers being checked visually (Monthly), and serviced (Annually)?
-
Are Fire Extinguishers mounted on wall brackets, with correct signage displayed?
-
Are Flammable Substances stored in a suitable Metal Cabinet (COSHH Cabinet)?
-
Are Passageways, Fire Doors and all exits clear of obstructions?
-
Is there a designated Smoking Area and is it being used?
Environmental Emergency Prevention & Mitigation
-
Have all Environmental Aspects and Impacts been assessed including the presence of Asbestos, PCBs or Lead Paint, etc?
-
Has an Asbestos Survey been completed with a Register available, have site workers been made aware of ACM locations, has Asbestos Awareness training been completed?
-
Is there a COSHH Register and Assessments available, detailing Use, Storage, Accidental Release Measures, etc. Signed by workers to confirm they have read and understood the assessment?
-
Is there a suitable COSHH Cabinet located on site to store hazardous substances?
-
Has a suitable location for refuelling been identified, on a Plant Nappy to prevent Oil, Fuel, and other Chemicals escaping into the environment, with a Spill Kit available?
-
Are there a suitable and sufficient number of Spill Kits available and accessible onsite?
-
Has Spill Drill training been completed in the last 6 months?
-
Are Plant Nappies in use under machinery where there is the risk of spillage, oil leaks or other hazardous substances leaking?
-
Is there a suitable Skip available for contaminated soil/waste, with appropriate signage ,identifying 'Special Waste'?
Emergency Preparedness
-
Has the emergency procedures been explained in the site induction to all visitors/site workers?
-
Has the Muster Point been located in a safe area and communicated in the site induction?
-
Is there a way to alert all site workers of an emergency?
-
Is the Emergency Warning system audible in all areas?
-
Are suitable First Aid Kits available on site?
-
Are suitable First Aid Kits available in company vehicles?
-
Are the First Aid Kits checked (Every 3 Months)
-
Are the First Aiders (Details Displayed) on site?
-
Has a test Emergency Evacuation been conducted?
Name & Signature of Auditor
-
Auditor Name
-
Auditor Signature