Title Page
-
Engineer Technical Audit - Access Control
-
Client / Site
-
Conducted on
-
Document No. SF_GEN_102-Engineer Audit Checklist and Report - Access V2
-
Prepared by
-
Location
-
Engineer Name
Technical Audit
-
Details of Job(s) to be audited
Audit to include:
: Measure of Technical performance
: Compliance Against Standards
: Competence in relevant tasks
: Further training requirements -
Type of work to be audited?
-
Installation
-
Maintenance
-
Job Number
-
Description of works being audited.
Legislative Compliance, Health and Safety and Environmental Audit
-
Does Engineer have all required PPE and understand how to use the equipment?
-
Has all electrical portable appliances in use by Engineer been tested as required?
-
Are all ladders and steps in good working on order and showing the appropriate tagging system?
-
Is the Engineer being audited aware of how to report hazards on site?
-
Are Risk Assessments/Method Statements available and have they been read and understood?
-
Where required, has a manual handling assessment been carried it?
-
Has waste management on site been dealt with appropriately?
-
Has work area been kept and left tidy?
-
Has waste been disposed of properly?
-
Please provide further relevant information below.
Technical Checklist
-
Does the installed system comply with the original spec/design and is acceptable workmanship
-
Did the engineer check that the requirements of the Code of Practice and BS EN 50133-7 and all other relevant requirements are met?
-
Did the engineer check that all wiring is correctly terminated and all mains connections have been checked for continuity and earthing in compliance with current IEE regulations?
-
Check that there is a fully completed Record of Operational Checks?
-
Did the engineer check that operation of all monitoring and control equipment is satisfactory?
-
Did the engineer check system database archiving facility is satisfactory?
-
Did the engineer check system printers and peripheral devices operate correctly?
-
Did the engineer check that the system continues to operate correctly to specification when mains supply is disconnected (if standby power supply specified)?
-
Have all cable penetrations been sleeved and fire stopped (where visibly checked)?
-
Is the mains supply dedicated, non-switched, correctly fused and labelled?
-
Did engineer check the device at each door is fitted as specified
-
Did the engineer check that the operation of each door functionality in stand alone mode, i.e. controller disconnected from network. (where specified)?
-
Did the engineer check the operation of each reader
-
Did the engineer check the correct operation of the regress button at each door.
-
Did the engineer check correct operation of locking device at each door?
-
Did the engineer check the operation of each emergency egress?
-
Did the engineer check correct operation of tamper/door ajar/release time?
-
Have all “as fitted” drawings been updated to include controller identification etc
Non Conformance/Observations or Opportunity for Improvement
-
Has the Engineer Audit been carried out without identifying any Non Conformances? Please provide details below of any.
-
Has the audit been carried out without identifying any Business process or procedure Non Conformance? Please provide details below of any.
-
Has the audit been carried out without identifying any other issues? Please provide details below of any.
-
Add signature
-
Add signature