Information
-
Site Name
-
Document No.
-
General Contractor/ Site Owner
-
Conducted on
-
Prepared by
-
Location
-
Personnel
-
Images
Preventative Maintenance Report It is recommended to have spare parts on site in the event that there is an equipment failure. Spare parts are a separate cost that are NOT covered under the preventative Maintenance Maintenance Agreement and would be an additional charge
-
Start Time
-
Serial number
-
undefined
-
Add media
At the time of the initial diagnostic service mobilization, the Technician will note any deficiencies in the existing system regarding compliance with UL325 standards and advise the customer of same. Systems that do not comply with current UL325 standards may or may not be serviced at this time at our discretion. Technician will also determine at that time if the requested work is covered under warranty, at which point some or all of the charges may be waived.
-
Are there any audible alerts
-
Are there any error codes
-
Are there any blown fuses or tripped breakers
-
Are there any LED lights active in the open, close or stop terminals indicating an inappropriate hold
-
Are there any LED lights active in the safety terminals indicating an inappropriate hold
Cycle count
-
Add media
-
undefined
Gate inspection
-
Does the barrier move freely and easily in manual operation
-
Is the barrier free of any visible damage
-
Is the barrier aligned correctly
-
-
Is the barrier path clear throughout entire travel
-
Add media
-
Are the hinges properly greased
-
Are all hinges and grease points properly lubricated and working as intended
Maintenance
-
Are all positive stops properly adjusted and functioning as intended
-
Has the chain been properly lubricated
-
Are all retractable spikes free of debris, retracting and all springs functioning as intended
-
Has the cabinet or inside of the operator been properly cleaned (Leaking fluids, debris etc.)
-
Are heat cables functioning as designed
-
Are all batteries free of corrosion and working at full or acceptable capacity
-
Are all barrier drains clear and free of debris
-
Are all chassis and mounting bolts tightly connected
Hydraulics
-
Are all hoses neat, clean and free of moving parts<br>
-
Are all hoses free of leaks<br>
-
Are all hoses tightly secured and in good condition
-
Are hydraulic fluids full
-
Does hydraulic pressure meet operator’s specified requirements
-
Are the bypass pressure valves in the “correct” position for normal operation
-
Has the Hydraulic fluid been changed on this P.M. trip
-
Where applicable, are all drive wheels in good working condition<br>
Electrical and Electronics
-
Are all wires tightly secured and in good condition
-
Does incoming Voltage meet operator’s specified requirements
-
Are the power switches in the “on” position
-
Are all accessory batteries at full or acceptable charge
Gate/ barrier functionality
-
When open command has been triggered, gate opens as designed
-
When stop command has been triggered, gate stops as designed
-
When close command has been triggered, gate closes as designed
-
Sequence of operations meets job specifications and performs as designed
-
Is the chain or drive rail properly aligned?
-
Is the area inside and around the operator/ HPU clean and free of debris
-
Does the photo eye function as intended
-
When the photo eye has been triggered, does the gate reverse as designed
Loop & Loop detector Details
-
Does the loop detector function as intended
-
Do all Loops test above the minimum 200 Megohms required for proper function
-
Do loops appear to be in good condition (Covered by sealant, leads twisted correctly, asphalt/ concrete in good condition etc)
Technician’s Recommendations
-
Do any replacement parts need to be ordered or installed
-
Comments
Final Pictures
-
Add media
-
Completion time
Electronic Signature Acknowledgement-I agree that my Electronic signature is a Legally and Binding Equivalent to my handwritten signature. Whenever I execute an Electronic Signature, it has the same validity and meaning as my Handwritten Signature. I will not at ANY time in the future, REPUDIATE the meaning of my Electronic Signature or Claim that my Electronic Signature is not Legally Binding.
-
Hercules High Security Representative
-
Customer representative’s signature