Title Page

  • Job Name

  • Job Number

  • Client / Site

  • Conducted on

  • Prepared by

  • Location
  • Foreman

  • 1. Confirm that soffit and ceilings heights are off of concrete, finish floor or benchmark established by the General Contractor.

  • Responsible Party

  • PCI Personnel Responsible For Correction?

  • Date Corrected?

  • 2. Prior to soffit/ceiling framing, verify that all required drywall top-out, caulking and fire taping is completed above ceiling.

  • Responsible Party

  • PCI Personnel Responsible For Correction?

  • Date Corrected?

  • 3. Verify that the horizontal track required for a joisted ceiling or soffit is attached through the drywall to a vertical stud.

  • Responsible Party

  • PCI Personnel Responsible For Correction?

  • Date Corrected?

  • 4. Verify screw attachment of studs to tracks (top, bottom and each side).

  • Responsible Party

  • PCI Personnel Responsible For Correction?

  • Date Corrected?

  • 5. Verify stud spacing is correct.

  • Responsible Party

  • PCI Personnel Responsible For Correction?

  • Date Corrected?

  • 6. Verify kicker, strong-back, bridging or wire installation is complete, if required.

  • Responsible Party

  • PCI Personnel Responsible For Correction?

  • Date Corrected?

  • 7. Verify that the horizontal stud layout does not interfere with MEPs.

  • Responsible Party

  • PCI Personnel Responsible For Correction?

  • Date Corrected?

  • 8. Verify that the openings for access doors are framed concurrent with production framing.

  • Responsible Party

  • PCI Personnel Responsible For Correction?

  • Date Corrected?

Corrective Actions

  • Enter any corrective actions that will be undertaken

  • Responsible Party?

  • PCI Personnel Responsible for correction.

  • Select date

  • Enter any corrective actions that will be undertaken

  • Responsible Party?

  • PCI Personnel Responsible for correction.

  • Select date

  • Enter any corrective actions that will be undertaken

  • Responsible Party?

  • PCI Personnel Responsible for correction.

  • Select date

  • Conducted By:

  • Reviewed By:

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.