Title Page
-
Job Name
-
Job Number
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Foreman
-
1. Verify that all required materials and equipment are stocked and in correct locations/ Verify accuracy of layout prior to framing.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
2. Verify accuracy of control lines, grid lines and benchmarks provided by others.
-
Add signature
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
3. Verify area is clean and free of debris prior to starting work.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
4. Verify that the all clips and top track are installed prior to fireproofing.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
5. Verify that the wall framing is straight, square, plumb and true within tolerance.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
6. Verify that electrical and plumbing rough-in and/or insulation does not protrude past the plane of studs.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
7. Re-verify that the wall framing is straight, square, plumb and true after MEP rough-in.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
8. Verify intersections at rated walls are correct.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
9. Verify that the pin attachments are correctly spaced and secure.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
10. Verify screws are installed in accordance with engineered shop drawings.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
11. Verify stud spacing is correct.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
12. Verify furred walls are braced to substrate.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
13. Verify that slap studs are in place.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
14. Verify that door openings are accurately sized and plumb with tape or level.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
15. Verify that the door frame elevations are correct.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
16. Verify that all headers are framed in accordance with plans and specifications and are square.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
17. Verify that king studs are installed correctly.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
18. Verify HM door frames are installed plumb, square and level with proper anchors.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
19. Verify that the backing is installed correctly and proper gauge and size.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
20. Verify that bridging (if required) is installed correctly.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
21. Verify that Non-Rated control joints are spaced no greater than 30 feet on center. Verify that there is a stud on each side of the control joint.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
22. Verify that Rated control joints and openings have drywall installed on face of stud within the cavity.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
23. Verify that the openings for access doors, recessed fire extinguisher cabinets and bath accessories are framed concurrent with production framing.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
24. Verify that layout for MEP penetrations is accurate and complete.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
-
25. Verify that plumbing pipes occurring within 6” of studs have been painted on floor.
-
Responsible Party
-
PCI Personnel Responsible For Correction?
-
Date Corrected?
Corrective Actions
-
Enter any corrective actions that will be undertaken
-
Responsible Party?
-
PCI Personnel Responsible for correction.
-
Select date
-
Enter any corrective actions that will be undertaken
-
Responsible Party?
-
PCI Personnel Responsible for correction.
-
Select date
-
Enter any corrective actions that will be undertaken
-
Responsible Party?
-
PCI Personnel Responsible for correction.
-
Select date
-
Conducted By:
-
Reviewed By: