Information
-
Visit No -
-
Retailer
-
Conducted on
-
Conducted by
-
In the presence of
-
Location
-
E-mail address
-
Date / Time of 2nd visit
-
Second visit conducted by
-
Date / First letter sent
-
Date / Time of 3rd visit
-
3rd visit conducted by
-
Date time second letter sent
1. Fire Safety Standars
-
1.1 are fire doors, fire exits, fire equipment and fire notices within the demise kept unobstructed
-
1.2 there are no visible breaches in compartmentasion or damage to fire stopping
-
1.3 are waste skips at least 10m from the buildings or are of the lockdown type
-
1.4 Are means of escape beyond demise clear or retailer storage
-
1.5 Are fire exit routes and doors unlocked and emergency fastenings and self closing devices operational.
-
1.6 Is stock kept clear of heaters, light fixtures, hot service pipes and electrical appliances
-
1.7 Is the sprinkler system capable of correct operation and not being misused. E.g Items being suspended from it or on top of it.
-
1.8 Is there a record of staff training in the evacuation procedures and immediate action in the case of fire
-
1.9 Are any flammable liquids kept away from possible sources of ignition and stored separately. E.g. Aerosols should be contained in small rooms with cages
-
1.10 Is there a smoking policy in place and is it enforced. E.g. Metal bins for waste ect, no evidence of elicit smoking
-
1.11 Are emergency route signs in-obstructed and if necessary illuminated
2. Electrical
-
2.1 Are boiler rooms, lift motor rooms, electrical rooms and cupboards clear of storage and easily accessible
-
2.2 Is all emergency lighting working and regularly tested / inspected
-
2.3 Are portable heaters securely guarded and located where they can not be knocked over or ignite combustibles.
-
2.4 Have portable electrical appliances been inspected in the last 12 months
-
2.5 Has a fixed wiring inspection been carried out within the last 5 years and a certificate issued
-
2.6 No unprotected trailing leads or use of multi socket block adapters, all lights switches and plug sockets fit for purpose
-
2.7 Are waste materials removed from the demise as frequently as necessary to ensure no unnecessary build up of dust or rubbish would attract pests
-
2.8 Is the use of cooking equipment. E.g. Toasters forbidden other than in designated kitchen areas
3. Kitchen Cleaning
-
3.1 Where applicable is the kitchen generally in a clean condition, and are kitchen extract duct filters in clean condition<br>( For catering outlets do they have a pest control contractor)
-
3.2 Where applicable has kitchen extract ducting been deep cleaned and a certificate issued within the last 6 months
4. Life, safety and Security Systems
-
4.1 Are sprinkler heads and fire detectors not impeded (by partitions or false ceilings) and are the required clearances beneath this equipment maintained at 0.5m
-
4.2 Is there a programmed maintenance system for sprinklers. When was the las test date
-
4.3 Where sprinklers are installed storage restricted to 2.6m high.<br>Category 1- In rack -3.5. Freestanding 4.0. Category 2 - In Rack 2.6 Freestanding 3.0. category 3 In rack 1.7 Freestanding 2.1<br><br>Category 1 Goods include food and drink in non combustible containers, leather shoes and non combustible products.<br>Category 2 Goods include clothing made from natural fibres, synthetic shoes, books food and drink combustible packaging, furniture and soft furnishings.<br>Category 3 Goods include synthetic clothing, plastic toys, electrical goods in plastic casing and toilet rolls, A minimum distance of 500mm must also be maintained at all times between the top of stored goods and the sprinkler head but should not be above the heights indicated above.
-
4.4 Is there a programmed maintenance contract for the fire detection alarm system, and the system tested weekly with records available
-
4.5 Are all fire extinguishers serviced, wall mounted, clearly signed and unobstructed
-
4.6 Are all break glass points correctly signed and unobstructed
-
4.7 Have fire suppression systems eg Ansul systems been serviced in the last 6 months, and are protective caps in place on the nozzels
-
4.8 Is there a fire log book in the unit and is it kept up to date
-
4.9 Is servicing / maintenance in place for any shutters or smoke extraction system within the tenants demise
5 Fire Risk Assessment
-
5.1 Has the unit carried out a Fire Risk Assessment, and is it available for inspection ( Must be dated within last year)
6 Health And Safety General
-
6.1 Unit free from ang signs of any apparent overloading effect that may affect the walls or flooring
-
6.2 Is there evidence of Any H&S risk assessments relevant to the unit
-
6.3 Are the General H&S standards satisfactory
-
6.4 Is there servicing / maintenance in place for gas boilers, cooking appliances and kitchen extraction systems
7. Building / Unit Condition
-
7.1 Plaster walls and ceilings in good condition
-
7.2 No sign of water damage or dampness including the suspended ceiling which would indicate ware penatration
-
7.3 No signs of damage to the internal structure which requires repair. Eg a hole in the wall
-
7.4 Is the shopfront / entrance in good condition and is the illumination in good working order
-
7.5 Are internal doors , staircases, windows and flooring in good condition
-
7.6 No sign of unauthorised alterations visible
-
7.7 Is the standard of decoration in good order, or is maintenance required
-
7.8 No sign of running water ie taps or toilet systern
-
Signed Unit Representative
-
Signed Site Representative
-