Title Page

  • Site conducted

  • Plot Number

  • Conducted on

  • Prepared by

Instructions

  • You will need the following items to be able to carry out this inspection effectively. Pa

  • Have you got a tape measure?

  • Set square

  • Boat level

  • Meter box key

  • Ladder to access loft

  • Torch for the loft

  • Tape to mark up decoration defects

External

  • Is there safe access to the plot

  • Does the main access have a ramped access that complies with part M

  • Does this match the drawing?

  • Take a Photo with the above answer

  • Are all air bricks clear of all debris and compliant with the NHBC Technical guidance

  • NHBC Technical Guidance (2020) - TG No: 7.2/15

Meter Boxes and Services

Gas meter box

  • Please select the type

  • Is the Ground gas box painted?

  • Is the gas earth bonding fitted?

  • Can the cable be pulled out the fitting

  • Is the lid damage free?

  • Is the Gas Connected and meter installed.

  • Can you smell gas?

  • Is the gas box mastic sealed externally?

  • Is the gas meter box door fitted?

  • Is the Gas Connected and meter installed.

  • Is the Gas meter box painted?

  • Is the gas earth bonding fitted?

  • Can the cable be pulled out the eath bond fitting?

  • is the puttly correctly sealed around the gas pipe in the cone?

  • Is the gas cone fitted?

Electric meter box

  • Is the Electric connected and meter installed

  • Is the hole in the electric meter box sealed wher the main tails come in

  • Is the electric box mastic sealed externally?

  • Is the electric meter box door fitted?

  • Is the electric meter box painted

Water

  • Is the water connected and is the meter installed

  • Can you see the water meter in the boundary box?

  • Is the boundary box full of debris?

  • Is external canopy fitted?

  • Is the canopy weather proofed

  • How is the canopy weather proofed

  • NHBC Technical Guidance (2020) - TG No: 7.2/15

  • Are the expansion joints sealed

  • Are all the extractor grills fitted correctly

  • Is the boiler flue sealed correctly

  • is the under side of the entrance doors mastic sealed or pointed

  • Are all the down pipes and gutter fixed and defect free

  • Are all the windows mastic Sealed

  • Are all window end caps fitted

  • Is the brick work defect free?

Rear Gaden

  • Is the garden toip soil compelte

  • Are the garden gravel margins compelte and filled with gravel?

  • Is the garden litter free?

  • Is the garden boundary fence complete and defect free?

  • Is the garden gate fitted?

  • Does the latch work correctly?

  • Does the bolt secure the gate correctly?

  • Is the manhole protection removed?

  • Are the manholes lids secure down correctly?

  • Is the outside tap fitted and operational?

Bedrooms

    Bedroom
  • Does the light work and the switch operate the correct way

  • Is the wall decoration a good standard

  • Is the gloss work a good standard?

  • Is the top of the doors and arc filled and painted smooth

  • Are the sockets and switches level?

  • Does door latch?

  • Does the door rattle?

  • Is the door stop fitted?

  • Is the Radiator level?

  • Are the windows and handles damage free?

  • Are the correct hinges on the window?

  • Are the trickle vents fitted and undamaged both inside and out side the window?

  • Make sure you leave the vents in the open position

  • Is the mastic complete to the window internal and around the window board?

  • Are the window restrictors fitted?

  • Do the restrictors operate correctly operate correctly?

  • Is the Part L mastic complete?

  • Is the floor damage free and all holes filled in?

  • Are their any screws under sockets left by the electrician?

  • Does this bedroom have a wardrobe?

  • Is it fitted correctly and to the customers choice if applicable?

  • Are their any customer choices applicable to this room?

  • are all the choices requested fitted and correct?

  • Does this bedroom have an ensuite?

  • Does the light work?

  • Does the extractor fan work?

  • Does the ensuite have an openable window?

  • Does the fan over fun?

  • Does the door latch?

  • Does the door rattle?

  • Does the lock work?

  • Is the lock tight/ stiff

  • Is the door stop fitted?

  • Is the Vinyl fitted?

  • Is the Vinyl mastic sealed?

  • Is the vinyl defect free?

  • Is the radiator level?

  • Toilet square and screw caps complete?

  • Does the toilet flush?

  • Is the toilet seat loose?

  • is the cistern fixed to the wall ?

  • Is all mastic complete to sanityware?

  • Which items are not masticed

  • is the hot and cold the right way around on bath, basin and shower?

  • undefined

  • does the plug work in the basin?

  • Are the copper pipes painted and secured?

  • Is the tiling compelte?

  • Is the plug fitted and connected to the over flow to the bath?

  • Is sanitary free from damage?

  • is the shower fitted and operational?

  • is the shower screen / rail fitted ?

  • is the window frosted?

  • is the window working correctly and defect free?

  • Is the wall decoration satisfactory?

  • Is the gloss work satisfactory?

  • Is the boxing square?

  • Are the choices correctly fitted and any customer extras also fitted.

Bathroom

  • Does the bathroom light work?

  • Does the bathroom extractor fan work

  • Is there an openable window?

  • Does the fan over run when the light is turned off.

  • Does the bathroom door latch?

  • Does the bathroom door rattle?

  • Does the bathroom lock work?

  • Is the bathroom lock tight/ stiff

  • Is the bathroom door stop fitted?

  • Is the bathroom Vinyl fitted?

  • Is the bathroom Vinyl mastic sealed?

  • Is the bathroom vinyl defect free?

  • Should any Vinyl be fitted?

  • Bathroom radiator level?

  • Toilet square and screw caps complete in bathroom?

  • Does the bathroom toilet flush?

  • Is the bathroom toilet seat loose?

  • is the cistern fixed to the wall in the bathroom?

  • Is all mastic complete to sanityware in bathroom?

  • Which items are not masticed

  • is the hot and cold the right way around on bath, basin and shower?

  • undefined

  • does the plug work in the bathroom basin?

  • Does the bath plug work?

  • Is the bath panel fitted correctly with the correct cover caps

  • Are the copper pipes painted and secured in the bathroom?

  • Is the tiling compelte in the bathroom?

  • Is the plug fitted and connected to the over flow to the bath?

  • Is sanitary free from damage in the bathroom

  • is the shower fitted and operational in the bathroom?

  • is the shower screen / rail fitted ?

  • is the window frosted in the bathroom?

  • is the bathroom window working correctly and defect free?

  • Is the bathroom wall decoration satisfactory?

  • Is the bathroom gloss work satisfactory?

  • Is the bathroom boxing square?

  • Are the choices correctly fitted and any customer extras also fitted.

Stairs/ Landing

  • Is stair/ landing wall decoration satisfactory?

  • Is stair/ landing gloss work satisfactory

  • Does the smoke alarm work on the landing?

  • Is the smoke alarm 300mm away from walls light fittings and lift trap

  • Is the green light showing on the Smoke/ Heat alarm? (this indicates the the mains power is connected)

  • Does the landing light work?

  • Is the two way stwitching for the landing light working?

  • Is the landing floor defect free and holes filled?

  • Is the gap at the top of the stairs filled with timber is over 10mm or grip fill if smaller.

  • are spindles 99mm or less a part?

  • Is stair tread protection removed?

Loft

  • Is the loft trap fitted and accesable?

  • Is the aerial cable securely fitted to the truss and visible from below the loft trap.

  • is the loft insulation ftted

  • Is the insulation level and touching all edges of the roof space with no gaps.

  • Does the bathroom fan require venting to a tile vent

  • Is the ducting connected and mechanically secure (metal jubilee clip used)

  • NHBC 2022 standards extract 8.1.12

  • Is the fan venting out the wall in the bathroom?

  • Is a durgo fitted to the SVP?

  • Is the SVP vented to a tile vent.

  • Is the pipe work correctly supported?

  • Is the durgo visable above the insluation?

  • Does the durgo have it's frost cap on?

  • Is there a gap in the felt at the ridge line?

  • Is the roof bacing correctly installed

  • Is the roof span over 8 m

  • If the span is over 8 meters is the chevron bracing fitted?

  • is the felt cut correctly by tile vents

  • Is there a party wall?

  • Is the fire stopping complete and is the spandrel panel undamaged.

  • are the lifting straps removed from the spandrel panel.

  • Is the spandrel panel compliant with the Standard details and NHBC Guidance below?

  • NHBC Technical Guidance - Spandrel Panels to cold roofs 7.2/25 (Jan 2018)

  • Truss Rafter Spandrel Panels - Guidance Documents

Front door

  • All front door ironmungary fitted?

  • Front door opens without effort?

  • Front door damage free?

  • Front door thumb turn fitted?

  • Door chain fitted?

  • spy hole fitted?

  • weather bar fitted to front door?

Hall

Consumer unit

  • Is the consumer unit compelte?

  • Are the install stickers on the consumer unit and filled in

  • Is the consumer unit the right height?

  • The RCD's should be between 1350 and 1450

  • Is the programmer operational?

  • Is the smoke alarm working on the ground floor?

  • Is the smoke alarm 300mm away from walls light fittings and lift trap

  • Is the green light showing on the Smoke/ Heat alarm? (this indicates the the mains power is connected)

  • Do the smoke alarms work when the power is turned off to the plot?

Lounge

  • Does the longe light work and the switch operate the correct way?

  • Is the lounge wall decoration to a good standard?

  • Is the lounge gloss work to a good standard?

  • Are the lounge sockets and switches level?

  • Does store door latch?

  • Does the store door rattle?

  • Is the door stop fitted for the W/C?

  • Is the lounge Radiator level?

  • Are the lounge windows and handles damage free?

  • Are the correct hinges on the lounge window?

  • Is the mastic complete to the lounge window internal and around the window board?

  • Do the lounge windows require window restrictors?

  • Are the window restrictors fitted?

  • Do the restrictors operate correctly operate correctly?

  • Is the Part L mastic complete in the lounge?

  • Is the lounge floor damage free and all holes filled in?

  • Is the TV/BT and internal phone line sockets installed corectly?

  • Is the programmer operational in the lounge?

  • Is the smoke alarm working on the ground floor?

  • Is the smoke alarm 300mm away from walls light fittings and lift trap

  • Is the green light showing on the Smoke/ Heat alarm? (this indicates the the mains power is connected)

  • Do the smoke alarms work when the power is turned off to the plot?

  • Are all required customer extras fitted.

W/C

  • Does the W/C light work?

  • Does the W/C extractor fan work

  • Does the W/C fan Boost work?

  • Does the W/C door latch?

  • Does the W/C door rattle

  • Does the W/C lock work

  • is it W/C lock tight/ stiff?

  • Is the door stop fitted

  • Is the W/C Vinyl fitted?

  • Is the W/C Vinyl mastic sealed

  • Is the W/C vinyl defect free?

  • W/C Rad Level?

  • W/C Toilet square and screw caps complete

  • Does the W/C toilet flush

  • Is the W/C toilet seat loose?

  • is the W/C toilet cistern fixed to the wall

  • Is all mastic complete to sanity in the W/C

  • Which items are not masticed

  • is the hot and cold the right way around on Basin in W/C?

  • does the plug work in the W/C basin?

  • Is the copper pipes painted and secured in W/C?

  • Are roses fitted in W/C?

  • Is the tiling compelte in W/C?

  • Is sanitary free from damaged in W/C?

  • Is wall decoration satisfactory in W/C?

  • Is gloss work satisfactory in W/C?

  • Check this room complies with part m

  • Does the W/C room comply with part m?

Kitchen

  • Is the kitchen door defect free?

  • Does the kitchen door Latch?

  • Does the kitchen door rattle?

  • Is the floor level in kitchen area?

  • Is the kitchen vinyl fitted

  • Is the kitchen vinyl mastic sealed?

  • Is the kitchen Rad Level?

  • Do the kitchen lights work?

  • Are their missing bulbs in the kitchen?

  • How many are missing

  • are the kitchen light switched the right way around?

  • Kitchen unit doors level and rubber sticky pads fitted?

  • Kitchen door defect free

  • Kitchen Units damaged free?

  • Are all the kitchen unit handles fitted.

  • All kitchen unit hinge covers fitted?

  • all kitchen unit screw covers fitted?

  • Plinths fitted to units?

  • Worktop damage free

  • Up stand damage free

  • Kitchen mastic sealed complety

  • Sink unit shelf fitted

  • Sink pipe work labled

  • Rosetts fitted to sink pipes

  • Is sink unit mastic sealed

  • Rented or shared ownership

  • Are appliances fitted and working?

  • Is extractor fitted and working including boost

  • Is boost switch labled

  • Is splash back fitted

  • does kitchen window operate correctly?

  • Is all ironmongery fitted to back door

  • does the back door open and close correctly

  • is the weather bar fitted to back door

  • Is the kite mark displayed on door glass front and rear doors?

Customer choices

  • are all customer choices and extras fitted correctly.

  • have sales done their choices check?

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.