Information

  • Document No.

  • Audit Title

  • Client / Site

  • Conducted on

  • Prepared by

  • Location

1 - Previous Audits

  • 1.1 - Have previous Audit Actions been reviewed?

  • 1.2 - Have all outstanding actions been reviewed?

2 - Documentation

  • 2.1 - Is the method statement available?

  • 2.2 - Are the Risk Assessments Available ? ( Flooring solution contractor installation documents)

  • 2.3 - Lift Plan Available & relevant?

  • 2.4 - Site Visit Report Available and relevant?

  • 2.5 - Drawing Available for Inspection ?

  • 2.6 - Site Specific PPE being Worn?

  • 2.7 - CSCS & CPCS cards checked and valid?

  • 2.8 - Has a Site Induction been completed ?

  • 2.9 - Has the relevant pre-start check been completed?

  • 2.10 - Toolbox Talks

  • Add signature

  • Add signature

  • Add signature

  • Add signature

  • Add signature

  • Add signature

  • Add signature

  • 2.11 - Lifting Equipment certification in date and valid?

3 - Crane

  • 3.1 - Mobile/Tower Crane pre-start check completed?

  • 3.2 - Crane provided is the type & size which is specified ?

  • 3.3 - Crane in position & orientation as noted in lift plan ?

  • 3.4 - Outrigger mats provided are the type and size specified?

  • 3.5 - Have overhead obstructions been risk assessed?

  • 3.6 - Are there any overhead obstructions ?

  • 3.7 - Crane Certification Available ?

  • 3.8 - Has all certification for lifting equipment been provided?

4.0 - Site Specific

  • 4.1 - Scaffold/handrails to perimeter of building access onto sufficient

  • 4.2 - Perimeter access scaffold no lower than 900mm from top of floor level?

  • 4.3 - Is there safe access to and from the work area?

  • 4.4 - Are openings protected eg. Voids/ stairwells?

  • 4.5 - Cleared level surface onto which passive fall protection can be installed appropriate?

  • 4.6 - Leading edge passive fall protection State type I.e airbags nets?

  • 4.7 - Passive fall protection around lorry/ trailer (full/partial deployment indicated on lifting plan

  • 4.8 - Safety Harness Attached to secure anchorage points when fixing stairs and landing?

  • 4.9 - Suitable access & working area for mobile crane & delivery vehicles ?

  • 4.10 - Exclusion zone to prevent access into or under working area by 3rd parties?

  • 4.11 - Window openings protected to prevent fall out risk at 2nd floor level & above?

  • 4.12 - Temporary propping designed supplied & installed by competent personnel if appropriate ?

  • 4.13 - Outer skin brickwork is no lower than 225mm from bearing level?

  • 4.14 - Mortar fully cured?

  • 4.16 - Window openings, 1200 or wider, to be propped prior to installation?

  • 4.17 - Temporary leading edge protection at the end of each working day installed?

  • 4.18 - All steel beams to be in place, securely restrained and if necessary propped?

  • 4.19 - Protection of service holes, within the floor area provided?

  • 4.20 - Has the grouting been carried out in accordance with the method statement?

5.0 - Other requirements

  • 5.3 - Is a first aider available from the principle contractor?

  • 5.4 - Has a provision of running water adjacent to each block/level been provide?

  • 5.1 - Has a provision of standard welfare been provided?

  • 5.5 - Has a provision of Central skips for removal of waste materials at no cost to FP McCann been provided?

Sign Off

  • Add signature

  • Add signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.