Information
-
Document No.
-
Audit Title
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Personnel
-
No electrical Boxes are installed back to back in sound rated assemblies
-
No sprinkler Heads installed back to back in sound rated assemblies
-
All insulation is installed properly and there are no voids
-
Insulation is installed behind electrical boxes <br>
-
Acoustical sealant is installed picture frame style (top edge, bottom edge and at adjacent walls) and at all penetrations in sound rated assembly.
-
Different colored 1" screws are being installed at sound channel locations. <br>
-
Sound channel is being installed at proper location and frequency (16" o.c. etc.) with screw installed on the bottom of the channel with fin pointed upwards.
-
Photos have been taken <br>
-
Materials being installed are per approved Submittals. <br> <br>
-
RC channel is not touching any adjacent framing members (intersecting walls or ceiling framing) to allow for movement. <br>
-
Drywall screws into RC channel are not touching framing members. <br>