  • MAIN CONTRACTOR:

  • PROJECT NUMBER:

  • QA SHEET NO:

  • ELEVATION/LOCATION:

  • COMMENTS:

  • FIXINGS STRAPS TO HORIZONTAL FIREBREAKS ARE INSTALLED CORRECTLY

  • ARE HORIZONTAL AND VERTiCAL FIREBREAKS INSTALLED TO CORRECT LOCATIONS AS PER DRAWING PACKAGE

  • FIXING STRAPS TO HORIZONTAL FIREBREAK ARE SPALYED CORRECTLY WITH STRAPS TRIMMED TO 15 TO 20mm,

  • THE CORRECT FIXING HAS BEEN INSTALLED TO THE HORIZONTAL FIREBREAK FIXING STRAP AND IS CORRECTLY SEATED TO FACE OF CONCRETE

  • FIXING STRAPS TO HORIZONTAL FIREBREAKS HAVE BEEN BENT CORRECTLY WITH NO DAMAGE OR COMPRESSION TO FIREBREAK FACE

  • HORIZONTAL FIREBREAKS HAVE THE CORRECT REQUIRED 23 TO 25mm CLEAR AIRFLOW REQUIREMENT

  • HORIZONTAL FIREBREAKS ARE NEATLY ABUTTED WITH NO GAPS OR DAMAGE, SILVER FOIL TAPE HAS BEEN INSTALLED TO TOP FACE OF FIREBREAK.

  • FIXINGS STRAPS TO VERTICAL FIREBREAKS ARE INSTALLED CORRECTLY

  • THE CORRECT FIXING HAS BEEN INSTALLED TO THE VERTICAL FIREBREAK FIXING STRAP AND IS CORRECTLY SEATED TO FACE OF CONCRETE

  • VERTICAL FIREBREAKS HAVE THE CORRECT 10mm OVERSIZE OF CAVITY REQUIREMENT

  • VERTICAL FIREBREAKS ARE NEATLY ABUTTED WITH NO GAPS OR DAMAGE, SILVER FOIL TAPE HAS BEEN INSTALLED TO TO FACE OF FIREBREAK.

  • A20 PROJECT MANAGER

  • CLIENT SITE MANAGER

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.