Information

  • Document No.

  • Client / Site

  • Conducted on

  • Prepared by

  • Location
  • Is this an Intrusive or non-intrusive Inspection

  • Fire Door Inspection

  • Fire Door

Door Location

  • Location

  • Add Image of door

  • Door Manufacturer Known

  • Certification Label Present

  • Add Image of Label

  • Is Door Data Available

Door

  • Door Type

  • Single or Double Leaf

  • Door Width

  • Door Height

  • Door Thickness

  • Door Width Leaf 1

  • Door Height Leaf 1

  • Door Thickness Leaf 1

  • Door Width Leaf 2

  • Door Height Leaf 2

  • Door Thickness Leaf 2

  • Does the door leaf sit against the door stop and is it free from distortion?

  • If the door is veneered or lipped, is the glue still holding these products firmly in place?

  • Fire signage

Door Frame

  • Door Frame Type

  • Is the frame in a good state of repair?

  • Is the door frame securely attached to the wall?

  • If a planted door stop is present, is it firmly attached?

Perimeter Gaps (mm)

  • What gap at head of door

  • What gap at hinged edge of door

  • What gap at closing edge of door

  • What gap at joining edge (Double Doors)

  • Are door leaf to frame gaps compliant

  • Is there a consistent gap under the door that allows it to swing without touching the floor covering?

  • Is the door to floor covering gap consistently 10mm (3mm if smoke seals are fitted) or less when the door is closed?

  • If the door leaf is fitted with a threshold seal, does the seal make contact with the floor covering when the door is closed?

  • Is the threshold gap compliant

Door Seals

  • Are intumescent seals in place?

  • What seal size is installed

  • Are the seals well attached inside the groove in the door leaf or frame?

  • Are brush or fin seals combined with the intumescent

  • Are brush or fin type seals free from damage?

  • Are separate smoke / acoustic seals attached

  • Are the smoke seals continuous around the door leaf or door frame?

Door Hinges

  • Are hinges CE / UKCA marked

  • Type of hinge

  • Are Hinges Positioned Correctly

  • Is there a minimum of 3 hinges with all the screws fitted?

  • Are all the screws the correct size?

  • Are the hinges packed

Door Closers

  • Is a closer required

  • Is a door closer Installed

  • Type of closer

  • Is the door closer CE / UKCA Marked

  • Open the door to 75mm or 5 degress. Does it close and engage with the latch

  • Is the closer securely attached to the frame

  • Is the closer free from damage

  • If unlatched does the closer hold the door in line with the frame and intumescent seals

  • If hung in pairs, do they close in-line if both are opened and released together

  • If hold open device is used, is it electronically released

  • Does the hold open device release the door when required

Lock, Latch and Hardware

  • Does the latch hold the door firmly in the frame without rattling

  • Is Panic / Emergency Set Installed

  • Is the lock CE / UKCA Marked

  • Hardware

Glazing & Glass

  • Is the door glazed

  • Is the glass marked as per EN14449 or EN 572: 3 or 6 or EN 1748-2-2 or EN 13024 or EN 14179 or EN 12150

  • Is the intumescent seal continuous and attached to the glass and bead?

  • Are the glazing beads well attached to the frame and free from damage?

  • Is the glass free from cracking or damage

  • If the glass has been replaced is it fire rated glass?

Compliance

  • Compliance Rating

Priorty Rating

  • Action required

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.