Title Page
-
Site conducted
-
Site Code
-
Tower Photo
-
Conducted on
-
Prepared by
-
Location
Tower Elevations
-
Antenna Locations and heights
-
Bracket locations and heights
-
Microwave dish locations, heights, and approximate bearing
Tower Structure
-
General Conditions Satisfactory?
-
Any loose bolts?
-
Any damaged members?
-
Any signs of unusual stress or vibration?
-
Any missing members?
-
Are climbing ladders, platforms, and safety equipment secure?
Structural Members
-
Spot check at least 10 bolts on the vertical tower members at intervals of approximately 8 metres apart on all tower faces
-
Specify locations and elevations of missing bolts/nuts
-
Any fractures, bends, or defective welds on structural members?
-
Are tower base anchor bolts tight?
-
Is general condition of stub antenna towers satisfactory?
-
Are guyed tower cantilevered joints above the guy level?
-
Guy and torque arm lugs satisfactory?
-
Are welds on equalizer plate where it connects to anchor shaft satisfactory?
Tower Foundations and Guy Anchors
-
Foundations and Anchors photo
-
General conditions satisfactory?
-
Is exposed concrete protected?
-
Are any cracks observed?
-
Are the any signs of movement?
-
Are anchors clear of brush, vines and trees?
-
Tower and anchors fenced?
-
Is guy anchor head clear of earth?
-
Any evidence of bolt erosion?
-
Any low spots that may collect moisture?
-
Guy plates and rods inspected for bends and fractures?
-
Concrete tower foundations inspected for cracking, spalling, and settling?
-
Guy anchor foundations inspected for cracking, weathering, and creepage?
-
Anchor rod below earth to a depth of at least 30 centimetres?
-
Has base of tower been properly grouted with sufficient drain holes?
-
Any obstructions in drain holes?
-
Have obstructions been cleared?
Guy wires and Fittings
-
Photo of guy wires and fittings
-
Guy wire size
-
General conditions satisfactory?
-
Connection points (top and bottom) in satisfactory condition?
-
Are end fittings secure?
-
Is rusting evident?
-
Is vibration observed?
-
All turnbuckles inspected for slippage and condition?
-
Turnbuckle jam-nut safeties and cable safeties inspected?
-
Guy cable clamps inspected for security and slippage?
-
All pre-forms inspected for unwinding and slippage?
-
All shackles, clevises, and thimbles inspected?
-
Guy wire dead ends inspected?
-
Did you visually inspect all guy wires with binoculars for broken strands and/or damaged insulators?
Guy wire Tension
-
Guy wire tension measurement
-
What method was used for the guy wire tension measurements?
Temperature, wind direction and velocity during guy wire measurements and adjustments
-
Temperature
-
Wind direction and velocity
Antennas, Microwave Dishes, and Transmission Lines
-
General conditions satisfactory?
-
Any loose hardware found?
-
Any antenna misalignment or physical damage present?
-
All antennas and microwave dishes inspected for any signs of damage and shifting?
-
All antenna mounting brackets, supports, and bracing inspected?
-
All transmission lines inspected for damage, loose bolts, and water/air leaks?
-
Inspection completed for loose or missing coaxial cable and waveguide clamps, supports, and restrainers?
-
Are transmission line supports no more than 1.5 metres apart?
Paint and Obstruction Marking
-
General conditions satisfactory?
-
Is painting necessary?
Rust and Corrosion
-
Does any part of the tower appear to have rust?
-
All antenna mounts and hardware inspected for rust?
-
All guy plates and rods inspected for rust and corrosion?
-
All guy cable clamps inspected for rust?
-
Transmission line clamps and hanger bolts inspected for rust?
Tower Paint
-
Any paint peeling, flaking, or fading?
-
Refer to Civil Aviation Safety Regulations 1998
-
Does paint meet CASA and Airservices Australia regulations?
Electrical and Lighting Systems
-
General conditions satisfactory?
-
Beacons present?
-
Beacon type
-
Any obstruction lights present?
-
Obstruction lighting type
-
All lighting working?
-
Inspection of internal wiring completed?
-
Are all drain holes open and clean?
-
Inspection of conduit, conduit clamp, and junction box completed?
-
Inspection of overall appearances of the electrical system connections completed?
Certification
-
Is the tower to a standard of satisfaction?
-
Explanation of unsatisfactory conditions
-
Field Technician name
-
Signature
-
Date and Time