Boral Party Wall System Checklist

  • Cavity between H-studs and frames on both sides is 20mm–40mm

  • PARTIWALL® bottom tracks are fixed to the slab with approved all steel fasteners 150mm maximum from each<br>end and at 600mm maximum centres

  • 6mm gap has been provided between adjacent PARTIWALL bottom tracks

  • Firesound sealant has been applied along the PARTIWALL bottom track at least on one side (NOT underneath)

  • PARTIWALL tracks have been fitted to SHAFTLINER™ MOULDSTOP panels around perimeter and screw fixed to<br>PARTIWALL top and bottom tracks at each level

  • PARTIWALL studs (not SHAFTLINER MOULDSTOP panels) are attached to framing on both sides with PARTIWALL<br>aluminium clips at maximum 3000mm vertically and 600mm horizontally

  • PARTIWALL studs in roof cavity are attached to roof framing with PARTIWALL aluminium clips as indicated in<br>PARTIWALL technical manual

  • PARTIWALL studs on upper levels are aligned with PARTIWALL studs below

  • PARTIWALL eave details have been constructed in accordance with PARTIWALL technical manual

  • Back-to-back PARTIWALL tracks (NOT PARTIWALL H-studs) are installed at horizontal joints between SHAFTLINER<br>MOULDSTOP panels

  • There are no penetrations through SHAFTLINER MOULDSTOP panels apart from any approved penetrations<br>in the roof space

  • No bridging occurs due to services between framing and SHAFTLINER™ MOULDSTOP panels

  • SHAFTLINER MOULDSTOP panels or other PARTIWALL components are not damaged

  • 16mm FIRESTOP® plasterboard is laminated to SHAFTLINER MOULDSTOP panels at 400mm centres in both<br>directions at floor-ceiling junctions and in the roof space and butt joints to fall centrally between PARTIWALL studs

  • Compressed Firepack™ mineral wool packer has been installed between the top PARTIWALL track and roofing<br>and between the end PARTIWALL tracks and external cladding

  • PARTIWALL system has been installed in accordance with installation specification and details contained in Knauf<br>PARTIWALL technical manual and any project specific instructions provided by Knauf

Comments / Actions

  • Comments

  • Photos

Sign Off

  • Supervisor Signature

  • Date and Time

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.