Title Page

  • Conducted on

  • Prepared by

  • Location

Untitled Page

  • Instructions
    -------------------
    1. Answer "Checked" or "Hold" for the questions below, then identify the personnel who conducted the checking.
    2. Add photos and notes by clicking on the paperclip icon.
    3. To add a Corrective Measure click on the paperclip icon, then "Add Action", provide a description, assign to a member, set priority and due date.
    4. Complete audit by providing digital signature.
    5. Share your report by exporting as PDF, Word, Excel or Web Link

Cladding Panel Background

  • Main Contractor: A2O Group

  • Project Number: C1218

  • Issued to: Cummings Group

  • Comments:

Y-Wall Board

  • Y-Wall board installed using the manufacturers recommended fixing centers and following A2O drawings using the recommended fixings. The boards must be sealed between the joints with fire mastic and covered with DAFA tape and then primer over the top.

  • Personnel

Tyvek Firecurb membrane.

  • Tyvek firecurb must be installed following the manufacturer's install guide using the correct tape with the correct 100mm laps. Any ripped or damaged membrane must be sealed using Tyvek tape.

  • Personnel

  • EPDM sealing windows to Y-Wall boards. Installed following the manufacturers install guide.

  • Personnel

Top hat, helping hand brackets and rails

  • Top hat and brackets are to be set out following A2O construction issue drawings. Fixings used must be on the fixing schedule.

Rockwool Insulation

  • Install Rockwool Insulation following the Rockwool installation guide following the fixing pattern and using the correct fixings specified on the A2O fixing schedule.

  • Personnel

Siderise Fire Barriers

  • Fire barriers must be installed following Siderise installation guide. It will be fixed using the fixing specified on A2O fixing schedule. All operatives installing fire barriers must be Siderise trained.

  • Area left clean and tidy

  • Personnel

Completion

  • Installer Signature:

  • A2O Signature:

  • Client Signature:

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.