Aluminium Rainscreen
-
Main Contractor:
-
Project Number:
-
Issued to:
-
QA Sheet No:
-
Elevation:
-
Level:
-
Comments:
STRUCTURE
-
Has handover documentation been issued by Main Contractor?
-
Personnel
- Installer
- A2O
Tyvek
-
Fire curbTyvek membrane installed and sealed with correct overlaps [Vertical 150mm and 100mm horizontal overlap.
-
Personnel
- Installer
- A2O
-
Tears and splits repaired and fully taped min 100mm overlap.
-
Personnel
- Installer
- A2O
Installation
-
Check fire barrier from previous inspection has not been damaged or dislodged.
-
Personnel
-
Existing Brackets have been re-secured with new fixings, new positions, or larger diameter within the same hole.
-
Personnel
- Installer
- A2O
-
Insect mesh secured to he face of the aluminium bracke.
-
Personnel
- Installer
- A2O
-
New aluminium feature flashing installed with colour coded rivets, in accordance with A2O design specification.
-
Area left clean and tidy with all hand marks cleaned from the flashing.
Completion
-
Installer Signature:
-
A2O Signature:
-
Client Signature: