Title Page

  • Conducted on

  • Prepared by

  • Contractors details

  • Correct tiles onsite as per TIle selection / addenda

  • Tile meeting with client completed

Safety

  • Trades wearing correct PPE

  • All electrical equipment tagged and in date

  • Hazard forms issued

Screed

  • Mortar mix ratio 1 part Portland cement 3-4 parts damp yellow sand

  • Nominal thickness of screed 25mm

  • shower hobs are square

  • Puddle flanges installed

Waterproofing

  • Floor wastes not blocked

  • No white set to areas of walls to be tiled

  • Completed in Accordance with part 3.8.1 of the NCC wet areas and external waterproofing

  • Waterproofing certificate sticker in meter box

Installation of ceramic tiles wet areas in accordance with AS3958.1

  • All surfaces are clean, firm, free of laitance, efflorescence, or oily films

  • Final bed thickness of adhesive does not exceed 3mm

  • Minimal voids occur in the adhesive once tile is bedded

  • Correct size notched trowel is used <br>

  • 200x200 tile - 8mm notched trowel

  • 250x250 tile- 10mm notched trowel

  • 300x300 tile- 12mm notched trowel

  • 400x400 tile and above - 12mm notched trowel including buttering of the tile

  • Application of adhesive to walls is horizontal

  • Minimum contact coverage of adhesive to tile

  • Wet areas - 90% minimum

  • Internal walls residential - 65% minimum

  • Residential floors - 80% minimum

  • Cut tiles have smooth edges and are installed without jagged or flaked edges

  • Installation of floor tiles to shower recess set out as per Gemmill detail

Tile finish and joints

  • Lippage between two adjacent tiles does not exceed 2mm

  • Any surplus adhesive within the joint of tile surface is removed prior to grouting

  • Joint widths are consistent throughout the installation

  • Floors - 3mm

  • Walls - 1.5mm

  • Fall within shower is between 1:60 and 1:80

  • Falls within wet areas is between 1:80-1:100

  • Main floor tiles finish a minimum 3mm from restraining surface

  • Tiling has been laid flat and true to within a tolerance of +- 4mm in 2m

  • Finished tile work is clean and free of pitted, chipped, cracked or scratched tiles

  • Grout finish to the depth of the cushion on cushion edge tiles

Completion of works

  • All rubbish placed in bin

  • Spare tiles stacked neatly in linen of pantry

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.