Title Page
-
Conducted on
-
Prepared by
-
Add location
Correct Tiles are onsite as per addenda
Roof safe required
-
Timber battens in accordance with
-
Battens are aligned to within a tolerance of +/- 20mm in 4m
-
Specified spacing tolerance does not exceed +/- 5mm
-
Battens laid on flat and fixed at every support
-
All batten joins are butt jointed over the centre of the rafter and are staggered
-
Anti-ponding board
-
Installed where no eaves overhang
-
Installed if roof is sarked and pitch is less than 20degrees
-
Roof not sarked
-
Water does not discharged onto roof tiles from gutter/valley or downpipe
-
Spreader pipes or flashing is installed to area where water is discharged onto roof from gutter / valley or downpipe
-
Roof tile set out and installation
-
Tiles laid in each or alternative course are in vertical alignment
-
All starters , finishers and full tiles at each course at a gable are mechanically fastened
-
Tiles overhang gutters a minimum of 50mm and a maximum of 65mm
-
Tiles to hips align in the same plane as adjacent tile
-
Ridge tiles are laid in a straight and regular line
-
Cutting of tiles at ridges, hips,verges and valleys shall be neat and present a straight line
-
Pointing is regular in appearance and has uniform colour
-
Valley cuts are secured to the tile batten, small valley cuts are secured by valley clips
Cleanliness and safety
-
All rubbish placed in bins
-
All trades have current white card
-
All gutters are clean and free of rubble
-
No off cuts of battens or tiles left on roof frame work
-
Select date