Information
-
Supervisor / Shot Firer
-
Conducted On
-
Location
-
Inspected By
-
SAP Work Order Number
Loading
-
Has a work area inspection been conducted to identify & control hazards?
-
Has the Blast Design Plan been checked against the actual pattern? (ensure differences have been documented)
-
Is the Blast Area delineated as stated in the Blast Work Instruction?
-
Are blast holes clearly defined as per site requirements?
-
Have all blast holes been measured for depth & accuracy? (ensure differences have been documented)
-
Have quantities of explosives/bulk products been determined using the Blast Design Plan? (ensure differences have been documented)
-
Has the type of equipment to be used been determined using the Blast Design Plan? (ensure differences have been documented)
-
Has the "Dewatering of Blastholes" procedure been followed?
-
Are explosive accessories distributed beside each hole in accordance with shot requirements?
-
Have primers been assembled in accordance with manufacturer recommendations?
-
Are Primers located within the blast hole as per Blast Design Plan?
-
Have the down-lines been firmly secured to wooden stake at the crest of the blast hole?
-
Have bulk product quantities been documented for each hole?
-
Have the quantities of stemming been added to each hole as per Blast Design Plan?
-
Has a Product Density Test been conducted for each load?
-
Are good housekeeping practices implemented in the Blast Area?
-
Have the load sheets been completed accurately for each blast in a timely manner?<br>(Check load sheets are legible, completed accurately & signed by the operator)
-
Have the completed load sheets been returned to the Blast Pack upon completion of loading shot?
Tie In of Pattern
-
Communicate with participating Blast crew. Are they able to explain tie in requirements & designated roles?
-
Is the Initiation system hooked up correctly? (non electric signal tube)
-
Are all lines connected?
-
Are all lines pushed to the rear of the clip?
-
Are all clips facing forward?
-
Is the connection by echelon or row?
-
Is the number of lines per connector acceptable?
-
Do all tails go to one side?
-
Are all tails approx. same length?
-
All bends in the signal tube to be wide & not tight. Is this system compliant?
-
Is the Hook up Initiation system compliant? (Detonation Cord)
-
Are all knots used approved & compliant?
-
Are all tails compliant? (length & secure)
-
Have the appropriate connectors been used? (with other forms of firing systems)
-
Has a number 8 detonator been used to initiate the det cord?
-
Have safety lines been installed?
-
Are the Control row / Firing Lines Compliant?
-
Is the tie in of control row from external point in to IP?
-
Were the firing lines managed within the blast area until advised the blast exclusion zone is secure?
Initiation of Blast
-
Have the Blast location & firing time been communicated to site? (via blast notice & site communication)
-
Have the blast guard positions been determined? (prior to blast taking place)
-
Have the blast guards been briefed on their position & responsibilities?
-
Has the Blast Exclusion Zone been secured?<br>(Blast guards / a visual drive around / check of all areas & equipment within exclusion zone to ensure no personnel inside blast zone)
-
Has the shot firer obtained permission to fire?
-
Shot firer takes control of the exclusion zone. Was the blast alarm activated & procedures communicated?
-
Was the firing procedure initiated by the shot firer?
Post Blast Inspection
-
Has the Post Blast Inspection been conducted?<br>(Check firing lines, suspect ground expression, wall stability, back break)
-
Has the "all clear" been communicated to site personnel? (if no evidence of misfire)
Misfires
-
Is there any evidence of a Misfire?
-
Are there any unfired holes?
-
Are there any bulges in walls/end walls?
-
Is there product residue on the bench?
-
Has the Misfire been communicated to operational personnel?
-
Has the Misfire been clearly marked? (survey / delineation / marker posts)
-
Misfire Recovery
-
Was the Misfire recovered successfully?
-
Was the Misfire reported correctly?