A Portable Residual Current Device (PRDC) is being utilised while using portable electrical equipment
-
No work is being undertaken with electrical tools or apparatus in metal enclosures or in damp places unless the tools are cordless
-
No workers are standing on metal ladders when using power tools unless they are cordless tools
-
No piggybacking through the use of double adapters is observed
-
All portable power leads are protected from impact damage and maintained off the ground (min 2 metres) where either the lead exceeds 10 metres in length, where it is out of sight of the user or where it crosses a pathway
-
Any electrical equipment being serviced is left on when unattended
-
Leads and lead plugs in good condition
-
Handles and guards are fitted to electrical tools and equipment
-
All electrical tools/ equipment fitted with current quarterly tag and details entered into a test/ tag register
-
Switchboards correctly labelled
-
Leads not obstructing walkways or access/egress
-
Electrical tools stored correctly when not in use
-
Pre-start inspections conducted on all electrical tools before being used
Actions required?
-
Action?
-
Allocated to?
-
By date
-
Add location
-