Fix, Pre-Paint & Waterproofing
-
Site conducted
-
Conducted on
-
Prepared by
-
Location
Untitled Page
Safety
-
Has weekly Safety Inspection been completed?
-
Has the house been swept out?
-
Has all rubbish been placed in the bin provided?
-
Are all tools tested and tagged?
-
Have all risks been assessed?
-
Are trades complying with their SWMS?
-
MSDS for waterproofing agent?
Plaster
-
All plaster offcuts have been put into the bin provided?
-
All external plaster corners are square and plumb?
-
All banding has been sanded smooth?
-
Wet area board has been installed to bathroom, ensuite and laundry?
-
Plaster ceiling to porches and Alfresco are 13mm Fyrecheck?
-
Check cornice to all rooms, including robes has been installed?
-
Pre-paint by plaster company has been completed after fix?
-
Check all cornice lines are straight and level?
Fix
-
All nails are punched?
-
Architrave mitres are sanded and flush?
-
Doorstops are nailed correctly - 1mm gap to latch side when shut and 3mm to hinge side?
-
All doors have a maximum 3mm gap to both sides and head with latch engaging correctly/
-
All doors must be packed on four places on both sides and installed plumb.
-
All windows are to operate freely and nailed home and punched?
-
All screws to hinges have been installed, and no hinges are damaged?
-
All latches line up with stricker plates and operate correctly?
-
Lift off hinges to wet areas have been installed correctly and the gap is adequate at the top?
-
All quirks around windows are consistent?
-
Manhole is installed as indicated on the plan (600x600)?
-
Joinery installed as per specifications and damage free?
-
Benchtop templates are on site?
-
Electrical/Heating cut outs have been done?
-
Place all left over fixing material in the garage.
-
Ensure the home is swept out and rubbish place in the bin provided?
Waterproofing
-
Are all works conducted in accordance with AS 3740:2021
-
Does waterproofing extend minimum of 150mm up the wall?
-
Are all pipes and drains penetrating the floor sealed?
-
All cracks are to be sealed prior to waterproofing?
-
Where floors meet walls, sealant or waterproof tape is to be installed?
-
Around all windows flexible sealant is to be installed between the window and wall membrane?
-
Shower screed is to be installed with a 1:80 fall and a minimum thickness of 10mm?
-
The shower outlet and spindles have been sealed?
-
The bath waterstop is in place?
-
Waterstop is installed to all door openings. Stud to stud?
-
Does the door waterstop finish half under the door?