Remedial Works
-
Main Contractor:
-
Project Number:
-
Issued to:
-
QA Sheet No:
-
Building:
-
Elevation:
-
Level
-
Comments:
RWA 45 Insulation
-
Check product is as per details and specification
-
Has the existing expanding foam and PIR insulation been remove as far as reasonably practical
-
Has the insulation been fully packed within the gap
-
Hold Point
Dowsil Firestop 700
-
Check sealant is suitably bonded to all adjacent structure
-
Hold Point
Galvanised Closers
-
Check the Galvanised closer is the correct thickness
-
Checked the fixings for type, quantity and arrangement as per design
-
Check the galvanised closers have been sealed to the structure with Dowsil Firestop 700
-
Have all edges of the closer been over-sealed with EPDM paste to ensure a watertight detail
-
Personnel
- Installer
- A2O
-
Hold Point
Final Checks
-
Has all the waste material been removed from the areas
-
Personnel
- Installer
- A2O