Quality Assurance
-
Main Contractor:
-
Project Number:
-
Issued to:
-
QA Sheet No:
-
Building:
-
Level
-
Comments:
Structure
-
Check the steelwork is free from corrosion, fixings and blockwork are in good condition or check the remedial works are complete.
-
Hold Point
Tyvek Firecurb Membrane
-
Correct membrane installed and sealed using the correct tape.
-
Personnel
- Installer
- A2O
-
Tears, splits or holes repaired and fully taped min 150mm overlap.
-
Personnel
- Installer
- A2O
-
Hold Point
Support Grid
-
Check all bracket fixings back to structure have the minimum edge distance and that mortar joints have been avoided.
-
Personnel
- Installer
- A2O
-
Vertical tophat been fitted as per drawings and the isolator tape installed between the tophat and panel.
-
Personnel
- Installer
- A2O
Vitradual Panels
-
Install the rail system as per the manufacturers installation guide, using the correct spec and qty of fixings shown on A2O drawings/install guide and fixing schedule.
-
Personnel
- Installer
- A2O
Completion
-
Check all panels have been installed without damage and to the correct standard
-
Installer Signature:
-
Supervisor Signature:
-
Management Signature: