Title Page
-
Document No. SF_GEN_103_Engineer Technical Audit Report - IDS
-
Engineer Technical Audit - IDS
-
Client / Site
-
Conducted on
-
Prepared by
-
Location
-
Engineer Name
Technical Audit
-
Details of Job(s) to be audited
Audit to include:
: Measure of Technical performance
: Compliance Against Standards
: Competence in relevant tasks
: Further training requirements -
Type of work to be audited?
-
Installation
-
Maintenance
-
Job Number
-
Description of works being audited.
Legislative Compliance, Health and Safety and Environmental Audit
-
Does Engineer have all required PPE and understand how to use the equipment?
-
Has all electrical portable appliances in use by Engineer been tested as required?
-
Are all ladders and steps in good working on order and showing the appropriate tagging system?
-
Is the Engineer being audited aware of how to report hazards on site?
-
Are Risk Assessments/Method Statements available and have they been read and understood?
-
Where required, has a manual handling assessment been carried it?
-
Has waste management on site been dealt with appropriately?
-
Has work area been kept and left tidy?
-
Has waste been disposed of properly?
-
Please provide further relevant information below.
Technical Checklist
-
Did the engineer check that the installation was completed in strict accordance with the agreed spec/amendments and is an acceptable standard of workmanship?
-
Did the engineer check to ensure that the installation complied with the applicable standards e.g BS8243, PD6662 and EN50131?
-
Did the engineer check that the mains connection is permanently connected, i.e not plug/socket, and the supply fuses are the correct rating?
-
Is there a fully completed record of operational checks? Review the record.
-
Check all batteries are clearly marked with installation date. Has the engineer clearly marked all batteries?
-
Did the engineer check the standby battery capacity complies with the applicable standards e.g PD6662, EN50131 and is recorded in the record of operational checks?
-
Was the voltage checked at all equipment?
-
Have all cable penetrations been sleeved and fire stopped (where visibly checked)?
-
Are all detection circuits clearly labelled by the engineer?
-
Has every detector been tested for correct operation through to control units and ensure no beam overlap/detection of different technologies within a single area?
-
Has the engineer checked for correct alignment of beam interruption detectors?
-
Did the engineer check and record the area or volume of coverage of movement/vibration/acoustic/pressure detectors? These must be walk tested.
-
Has the engineer tested the correct operation of all tamper circuits?
-
Has the operation of audible following both system activation and when the hold off has been removed from self activating devices been tested?
-
Check the “engineer reset” is set where applicable.
-
Has the engineer checked the remote signalling system for correct operation.
-
Is the system operating procedure displayed or on the control unit and is appropriate for the correct operation of the system?
-
Has the engineer checked the entry/exit route time(s) are correct and recorded?
-
Check that the method of operation of setting and unsettling is as per specification.
-
Has the engineer checked that any loss of signal transmission is alerted at the control and indicating equipment?
-
Has the engineer checked that the keypad code functions are inhibited on entry as per specification?
-
Has the engineer checked that detector LED’s operate as per specification?
Non Conformance/Observations or Opportunity for Improvement
-
Has the Engineer Audit been carried out without identifying any Non Conformances? Please provide details below of any.
-
Has the audit been carried out without identifying any Business process or procedure Non Conformance? Please provide details below of any.
-
Has the audit been carried out without identifying any other issues? Please provide details below of any.
-
Add signature
-
Add signature