Information

  • DA/CDC/CC Number

  • Client / Site

  • Location
  • Conducted on

  • Health and Building Surveyor

1. Previous Inspections carried out

  • 1.1. Internal sewer

  • 1.2. Footings

  • 1.3. Floor slab

  • 1.4. Internal water

  • 1.5. External sewer

2. Ongoing Matters for Builder/Contractor to check

  • 2.1. Restricted access

  • 2.2. Builder's sign

  • 2.3. Sediment and erosion controls

  • 2.4. Rubbish control

  • 2.5. Builder's toilet

  • 2.6. Protection of public space by fence or hoarding

  • 2.7. Protection and support of adjoining buildings

3. Health and Building Surveyor's Checklist

3.1. Frame

  • 3.1.1. Check floor plan with approval

  • 3.1.2. Underfloor access

  • 3.1.3. Sub-floor ventilation

  • 3.1.4. Antcapping and damp-proof course

  • 3.1.5. Floor bearers/joists spacing/size/crippling

3.1.6. Two-story construction

  • 3.1.6.1. Deep floor joists/blocking, spacing size

  • 3.1.6.2. Wet area flooring/grade flooring

  • 3.1.6.3. Timber grades/sizes and support

  • 3.1.6.4. Straightening of studs

  • 3.1.6.5. Blocking to corner junctions

  • 3.1.6.6. Bracing

  • 3.1.6.7. Hold down of roof and walls

  • 3.1.6.8. Wall sisilation

  • 3.1.6.9. Insulation provided

  • 3.1.6.10. Ceiling heights

  • 3.1.6.11. Heads and lintels

  • 3.1.6.12. Steel sizes

  • 3.1.6.13. Flashing of windows and doors

  • 3.1.6.14. Sufficient support under point loads

  • 3.1.6.15. Wall ties in place along with brickwork

  • 3.1.6.16. Roof/trusses/bracing under load

  • 3.1.6.17. Roof sisilations/gap at ridge

  • 3.1.6.18. Fixing of roofing/batten size, spacing

  • 3.1.6.19. Cavities/weep holes clean

  • 3.1.6.20. Engaged piers in single-brick walls

3.1.7. Split-level construction

  • 3.1.7.1. Cut fill, retaining wall/subsoil drainage

  • 3.1.7.2. Engineer's design, beam/lintel/retaining wall

  • 3.1.7.3. Builder on site

  • 3.1.7.4. Sticker left on site

3.2. Hot and Cold Water Service

  • 3.2.1. Licensed plumber

  • 3.2.2. Under pressure test (1500Kpa - 30 minutes)

  • 3.2.3. Approved material and size

  • 3.2.4. Length of branches and number of fixtures

  • 3.2.5. Clipping/support

  • 3.2.6. Cover/insulation

  • 3.2.7. Pipes touching dissimilar metals

  • 3.2.8. Tempered Water Connected/Valve/Test to ensure 50 degree Celsius or less

  • 3.2.9. Cross connections

  • 3.2.10. External cover/depth

  • 3.2.11. External - connection to meter

  • 3.2.12. External - separation from other services

  • 3.2.13. Plumber on site

  • 3.2.14. Sticker left

4. Comments

  • 4.1. Result

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.