Title Page

  • Conducted on

  • Prepared by

Subcontractors Trading Name

  • Trades details

Site Safety

  • All electrical equipment is tagged and in date

  • All rubbish has been placed in containment bin

  • All contractors have current white card

  • Site has been left clean

Inspection Final Fit Off

  • All door furniture installed is as per addenda

  • Privacy sets and passage sets installed to doors as per addenda

  • Deadlocks installed

  • All striker plates have been adjusted

  • All door seals have been installed to entry TDF

  • All Door furniture operates as intended and is not defective or damaged

Final Fit Off Tolerances

  • Finished clearances between door leafs and frames is not less than 2mm or greater than 5mm

  • Clearances to bottom of doors does not exceed 20mm after installation of flooring

  • Surface alignment between meeting edge of double or French doors does not exceed 5mm

  • Bending heights in door heights up to 2150mm does not exceed 4mm

  • Bending in door heights between 2150mm and 2400mm does not exceed 6mm

Supervisor Signature

  • Signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.