Title Page

  • Conducted on

  • Prepared by

  • SUB CONTRACTOR TRADING NAME

  • Site safety management plan onsite

  • Plans and addenda have been reviewed and assessed

  • Correct revision plans are being used

MATERIALS

  • Cement used - Floatcem

  • No plasticisers are used

  • R02 galvanised corner beads installed to all trafficable areas and are level and square

  • No corner beads used in wet areas

  • Water drum has a lockable lid or water emptied at end of each day

  • No contaminants in plastering sand eg rocks etc

Preparation of Backgrounds- In accordance with Guide to plastering standards HB -161

  • No surface contaminants are on walls eg paints, oils, adhesives , dusts etc

  • Walls are not overly wet ( if yes ,due to rain a v/o for time extension is required to allow drying time)

  • Water being used is free from impurities

  • All aluminium window frames and / or doors are protected / covered

  • Rooms are swept out and clear of debris / loose material

Application And Finish in accordance to plastering standards HB 161

  • All float mix ratio's comply with manufactures specification ( cement lime , water ,sand ratio)

  • Walls and other vertical structures - tolerance 6mm in 2.4m

  • Reveals sides - vertical - tolerance 3mm in 1.8m

  • Reveals head up to 1.8m - horizontal - tolerance 3mm in 1.8m

  • Reveals head over 1.8m - horizontal - tolerance 3mm in 1.8m

  • Reveals, piers , beams, wall stop ends over 300mm - square - tolerance - 5mm max

  • Radius of corners - round - should not vary by more than +/- 10% over the Length of the radius

  • Reveals, piers , beams , wall stop ends up to 300mm - square - tolerance -3mm max

  • Margins exceeding 25mm in width and surrounding metal door frames should be recessed

  • Margins not exceeding 25mm in width and surrounding metal door frames are to be finished flush with the surface of the metal frame and a "v" groove installed in the float at the abutment to the frame.

  • Nominal thickness of plaster float 8-10mm

  • All wet areas walls are square and level

  • All excess float cleaned off and removed from top wall plate, underside of roof cover, external eaves ,gutters and flashings

  • "V" grooves installed at abutments to all window frames

  • All excess droppings from ruling off to be placed in or next to containment bin or where otherwise specified by supervisor

  • Floor scrape completed and door frames left clean

External render

  • No plasticisers used in float mix

  • External render completed prior to glazing

  • Render extends down to footing height

  • Render to entry door threshold does not cover drainage to front of sill

  • Gutters, fascia and roof sheeting left clean no damage

  • All rubbish placed in containment bin

Site Safety

  • Hazard forms issued

  • Electrical tools tagged

  • Site left clean

  • Add signature

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.