Title Page

  • Project Name:

  • Project No.

  • Slab Level:

  • Pour Number:

  • Select date

  • Leading Hand:

1. PT installed to per drawing and revision number:

  • D & C by Fortec Australia

  • Install only, designed by external engineers

2. Check anchorages as follows: 12.7mm / 15.2 mm

  • Positioned with tolerance

  • Secured to prevent displacement

  • Number of slab anchorage installed<br>Is this different to the amount on the drawing

3. If you answered 'No' to any of the above comment on why:

Coil number / tag ID:

  • Coil 1

  • Coil 2

  • Coil 3

  • Coil 4

  • Coil 5

  • Coil 6

Check ducting and strand as follows:

  • Correct number of stands in each tendon

  • Tendons positioned in accordance with layout plan

  • Tendons profiled and secured

  • Sufficient jacking length of strand available

  • Grout hose installed and secured

  • Duct joints and grout tubes are sealed at both ends

6. If you answered 'No' to any of the above comment on why:

  • 7. Anti-burst reinforcement installed to all tendons (observation only if installed by others)

  • If 'No' - has the builder been informed?

  • Has the Engineer's Inspection report been received from the builder?

  • Are all items on the Engineer's Inspection report complete?

If you answered 'No' to any of the above, comment why:

  • Main Contractor (Print Name and Sign)

  • Fortec Leading Hand (Print Name and Sign)

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.