The following page starts the inspection. Every question relates to something Bierce has pulled us up on. Please ensure everything is checked properly.
Inside Inspection
-
Is there background ventilation in all habitable rooms? (photos required) Background ventilation: Window Trickle Vents or Wall Vents
-
Is there dMEVs in all wet rooms, are they fully sleeved and are they all operational (photos required) Wet rooms: Bathroom, Kitchen, Ensuite, WC with a sink and a Utility room with a sink
-
Do all habitable door undercuts have at least 7-10mm clearance?
-
Have you checked above the boiler for the integrity of the boiler flue? (photo required)
-
Is there a core vent in place if there is a back boiler or gas fire? (photo required)
-
Customer Question: Is everything working correctly? Eg TV, Lights, Sockets, Taps, Guttering
Outside Inspection
-
Is there sufficient jacks and are they in good condition? (photos required) 8 for a single, 16 for a double
-
Is there a 6m minimum difference between park homes
-
Has cross flow ventilation been installed into the apex?
-
Have all vents been filled with plastic vent ducting? And no polystyrene is showing through the vent hole
-
Is the extractor fan vents ducting attached to the outside vent cover with no gaps?
-
Are there 3 clips on all guttering down pipes (photos required)
-
Is the guttering connected securely all the way around?
-
Have you ensured there are no gaps in the insulated system? For example, under the apex in the corner or cracks around windows etc
-
Have all exterior walls been insulated? (Basically any wall that keeps the inside of the home warm needs to have insulation on it on the outside)
-
Are any outside pipes/water taps secured correctly and are they lagged? (photos required)
-
Has everything been siliconed where necessary? (Lights, Vent Covers, Under the Base Rail Corners, Under Window Sills, Gateposts, Water Taps, Door Numbers)
-
If there is a Surface Mounted Electric Box, does it have insulation on the inside wall of the park home where the Electric Box protrudes?
-
Is there uPVC Trim on Both Corners of Bay Windows or Chamfered Doors?
Other
-
Is there any other snagging on the Park Home?