  • The following page starts the inspection. Every question relates to something Bierce has pulled us up on. Please ensure everything is checked properly.

Inside Inspection

  • Is there background ventilation in all habitable rooms? (photos required) *Background ventilation window trickle vents or wall vents

  • Is there dMEVs in all wet rooms, are they fully sleeved and are they all operational (photos required) Wet rooms: Bathroom, Kitchen, Utility Room and WC

  • Do all habitable door undercuts have at least 7-10mm clearance?

  • Is there a core vent in place if there is a back boiler or gas fire? (photo required)

  • Have you ensured any sub floor ventilation remains open? (usually sub floor vents if the oven sits on the floor)

Underfloor Inspection

  • Has the home got sufficient access (at least 1 hatch per side of the axle)

  • Is there adequate ventilation under the park home? (1 air brick/vent on each long end, 2 air bricks/vents on each short end)

  • Is there sufficient jacks supporting the chassis and are they in good condition (photos required) 8 for a single, 16 for a double

  • Have all water-feed pipes been lagged?

  • Is the system fully sealed & battened to ensure no cold bridging (photos required)

  • Have you ensured that you have not covered up a gas pipe

  • If any gas pipes are running underneath between the joists, have you ensured you have cut ventilation into the system

The templates available in our Public Library have been created by our customers and employees to help get you started using SafetyCulture's solutions. The templates are intended to be used as hypothetical examples only and should not be used as a substitute for professional advice. You should seek your own professional advice to determine if the use of a template is permissible in your workplace or jurisdiction. You should independently determine whether the template is suitable for your circumstances.