Title Page
-
Date
-
Company Name
-
Installer Name
-
Customer Name
-
Address
- ***Enabling Works
-
What enabling works are you doing?
- Install dMEV Fan in Bathroom
- Install dMEV Fan in En-Suite 1
- Install dMEV Fan in En-Suite2
- Install dMEV Fan in Kitchen
- Install dMEV Fan in Sanitary / WC
- Install dMEV Fan in Utility Room
- Install *Intermittent* Fan in Bathroom
- Install *Intermittent* Fan in En-Suite 1
- Install *Intermittent* Fan in En-Suite2
- Install *Intermittent* Fan in Kitchen
- Install *Intermittent* Fan in Sanitary / WC
- Install *Intermittent* Fan in Utility Room
- Replace Existing Fan (Straight swap)
- Extend / Relocate Sky Dish
- Extend / Relocate TV Aerial
- Extend / Relocate Incoming Telephone Wire
- Extend / Relocate Socket
- Extend / Relocate BT Telephone Box
- Other (type in notes)
-
Before Photo of Fan
-
After Photo of Fan (One photo showing the cables in the fan, One photo showing the fan finished on the wall/ceiling)
-
Fan Used
-
Is the fan fully ducted to outside (If ducting runs through the loft please take a photo)
-
I have used a 3 core cable to supply the fan and have not used the earth as a switch live
- Yes
- No
- This fan is an on/off fan so only has a 2 core cable and earth
-
Photo of Fan Isolator (One photo showing the cables in the isolator, One photo showing the isolator finished)
-
Is the fan on continuously and boosted via a switch
-
How is the fan boosted?
-
Photo of Boost Switch
-
Is there a 3 amp fuse protecting the circuit if coming off a circuit other than a 6 amp circuit breaker? (Photo required)
-
Photo of External Grill (For UFI Please install grill and silicone around edges | For EWI Please install HD board and install grill)
-
Has the external grill been siliconed? (If UFI)
-
Any Comments or Additional Photos?
-
Toilet /Sanitary accommodation – 6 l/sec (22m3/hr).
Bathroom/Shower Room – 15 l/sec (54 m3/hr).
Kitchen with cooker hood – 30 l/sec (108 m3/hr).
Kitchen without cooker hood – 60 l/sec (216 m3/hr).
Utility Room – 30 l/sec (108 m3/hr). -
Before Photo of Fan
-
After Photo of Fan (One photo showing the cables in the fan, One photo showing the fan finished on the wall/ceiling)
-
Fan Used
- Anda 100m Axial Fan with Timer
- Anda 150mm Axial Standard Fan
- Monsoon Zone 1 Silence Range (100mm)
- Monsoon Zone 1 Silence Range (125mm)
- Monsoon Zone 1 Silence Range (150mm)
- Other (please add in notes)
-
Photo of Fan with tape measure to show size (100m, 125mm, 150mm)
-
I have used a 3 core cable to supply the fan and have not used the earth as a switch live
- Yes
- No
- This fan is an on/off fan so only has a 2 core cable and earth
-
Is the fan fully ducted to outside (If ducting runs through the loft please take a photo)
-
How does the fan turn on?
-
Photo of Fan Isolator (One photo showing the cables in the isolator, One photo showing the isolator finished)
-
Photo of External Grill (For UFI Please install grill and silicone around edges | For EWI Please install HD board and install grill)
-
Has the external grill been siliconed? (If UFI)
-
Any Comments or Additional Photos?
-
Before Photo
-
After Photo
-
Any Comments or Additional Photos?
Other
RCD (If applicable)
-
Are the fan circuits protected via an RCD
-
Photo of RCD protection
Customer Sign Off
-
Are you happy with the above works?
-
Have fans been installed?
-
Have you been given clear instructions on how the fans operates?
-
Have you been notified that you will receive a minor works certificate in the post?
-
Customer Sign Off