Title Page
-
Date
-
Tech Survey Prepared by
-
Park Homeowner Name
-
Park Home Address
Drawn Plans
-
Please take a photo of the Distance Drawing and Ventilation Diagram
-
Property Type
-
Please take photos of all elevations of the property (all angles - 8 photos should cover it)
-
Is there adequate skirt ventilation?<br><br>We need 1 skirt vent on each short end and 2 skirt vents on each long end (6 total)<br><br>*Photos required of the skirt vents (if applicable)
-
What skirt ventilation strategy do we need to implement? Multiple Selections Allowed
- Install 1 New Skirt Vent on the Long Ends
- Install 2 New Skirt Vents on the Long Ends (either 2 on one side or 1 on each side)
- Install 3 New Skirt Vents on the Long Ends (2 on one side, 1 on the other side)
- Install 4 New Skirt Vents on the Long Ends (2 on both sides)
- Install 1 New Skirt Vent on the Short End
- Install 2 New Skirt Vents on the Short End (1 on each short end)
-
Fuel Type<br><br>*Photo required of fuel source
EWI
-
Are you doing an EWI Tech Survey / PIBI?
-
Construction of Park Home Skin?
- Plywood
- Aluminum
- uPVC Cladding Therefore remove
- Other: See notes
-
Do any of the walls require plywood change?
-
How many SQM require changing? Please also take photos of the areas that need replacing
-
How many window sills will be required?
-
What colour are the window sills? *1 photo required
- Brown
- Rosewood (red/brown)
- White
- Grey
- Other
-
Is the Park Home Soffit over 100mm on the Long ends?<br><br>*1 photo required with a tape measure measurement
-
Is the Park Home Soffit over 100mm on the Short ends?
-
What are we doing with the Apex? *Photos required of both sides
- Insulate both Apex's as it has an overhang
- Remove cladding and insulate both Apex's as it has an overhang
- Insulate Front Apex / Leave Rear Apex
- Insulate Rear Apex / Leave Front Apex
- No Overhang - Can't Insulate Apex's
-
Chamfer Insulation (Comment in notes)
- Doors
- Bay Windows
- N/A
-
Width of park home in meters
-
Length of park home in meters
-
Size of Park Home SQM
-
What is the height of the park home from the drip rail to the soffit in meters?
-
Is there a Porch or Inverted/Recessed Porch? Please take photographs to showcase the porch area. In case there are any smaller areas, please include a photo with a tape measure for accurate measurement.
- Yes
- No
-
Is the Porch to be included in the install?
- Yes - Insulate Inverted/Recessed Porch
- Yes - Insulate External Porch as there is adequate overhang
- Yes - Insulate the inside wall of the porch (specifically the original exterior wall which is now located inside the porch) as there isn't adequate overhang.
- Other: See notes
-
Any porch enabling works required? Take photos and add items in notes
- Yes - there are enabling works
- No - there are no enabling works
-
Is there a Conservatory?<br><br>Please take photographs to showcase the conservatory area. In case there are any smaller areas, please include a photo with a tape measure for accurate measurement.
-
Is the Conservatory to be included in the install?
- Conservatory: Yes - Insulate the inside wall of the porch (specifically the original exterior wall which is now located inside the conservatory)
- Conservatory: No - Do not insulate the inside wall (the originial exterior wall) as there is a heating source
- Other: See notes
-
Any conservatory enabling works required? Take photos and add items in notes
- Yes - there are enabling works
- No - there are no enabling works
Obstruction to insulation and how to deal with them
-
*Electrical Works - Surveyor, please take photos of any items below
-
Outside BT Telephone box or Incoming Wire from a pole?
- Ok where it is
- Extend
- Relocate
- No Telephone wire/box
-
TV/Sky?
- Ok where it is
- Bring out on Baton
- Relocated to Fascia
- No TV/Sky
- N/A
-
Telephone/Aerial Wiring - Trunk or Bury?
- Trunk
- Bury
- N/A
-
Electrical Wiring - Trunk or Bury?
- Trunk
- Bury
- N/A
-
Electric box in use or Empty?
- In use
- Empty
- N/A
-
External electric socket, light switch or external junction box?
- Ok where it is
- Extend
- Relocate
- No External Electric Socket
-
Any other Electrical items that needs extending? (Leave comments in notes)
-
*Gas Engineer Works - Surveyor, please take photos of any items below
-
LPG Regulator and pipes?
- Ok where it is
- Extend
- Room to work Behind
- No LPG Regulator
- N/A
-
External Water Tap?
- Ok where it is
- Extend
- Relocate
- No External Water Tap
-
Is there a Boiler Flue? (photo required of Boiler Flue either on wall or roof)
-
Does the Boiler Flue need extending? (photo required with measurement or 60mm insulation next to the flue)
- Yes - Extend Boiler Flue
- No
-
Pressure Release Valve
- Ok where it is
- Extend
- Relocate
- Can't see one on the wall
- N/A
-
Soil Vent Pipe
- Yes
- No
-
If AC unit - please take photo of the label (this also includes any external Oil Boilers)
-
Any other pipework that needs extending? (Leave comments in notes)
- Yes
- No
-
*Installer Works - Surveyor, please take photos of any items below
-
Gate/Fence/Railing post adjustment (leave comments in notes)
- Adjust
- Work around
- Big enough gaps to add insulation
- N/A
-
What material is the Gate/Fence made out of?
- Wood
- Metal
- Not sure (take photos)
-
Is there a Hand Rail?
- Yes
- No
-
Brick work (leave comments in notes)
- Cutback
- Box around with 10mm clearance
- Enough gap on brickwork to put insulation behind
- No brickwork
- N/A
-
Decking (leave comments in notes)
- Adjust
- Box with 10mm clearance
- No Decking
- N/A
Extra Work
-
*Extra Works - Surveyor, please take photos of any items below
-
Shrubbery/Trellis/Bushes
- Yes - customer notified that they will need to trimback for the team
- No shrubbery / trellis / bush removal required
- Other: See notes
-
Mock Tudor/Corner Quoins/Decorative Brick Features/Small Cladding
- Customer has been told that these will be removed and not put back on
- No decorative items to remove
- Other: See notes
-
Is there anything else on the wall that might need moving or will impact the installation?
-
Extra comments regarding the job
Underfloor Insulation Inspection
-
Are you doing an UFI Tech Survey / PIBI?
-
If you are doing just a single UFI what is the *width* of the home<br><br>Ignore if you answered this in the EWI section
-
If you are doing just a single UFI what is the *length* of the home<br><br>Ignore if you answered this in the EWI section
-
If you are doing just a single UFI what is the SQM?<br><br>Ignore if you answered this in the EWI section
-
Is there a minimum of two accessible hatches, and are they situated opposite sides of the axle stands? <br><br>*Photo required of each hatch
-
How many hatches need to be installed?
-
Once the drip rail has been removed will there be a gap from the park home to the skirting? (leave comments in notes)<br><br>*Please take a photo of measurement for the installers if applicable
-
Number of Jacks (8 required for a Single, 16 required for a double) - Please ensure jacks are supporting the chassis, we don't count jacks not on the chassis.
- 8 (or more)
- 16 (or more)
- The minimum number of Jacks is not present
-
How many total additional Jacks are required?
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
-
What size jacks are required? (the quantity will generate below)
- Small Jack (10.5 inch - 15 inch / 26.67cm - 38.1cm)
- Medium Jack (12.5 inch - 15 inch / 31.75cm - 38.1cm)
- Large Jack (15 inch - 18.5 inch / 38.1cm - 46.99cm)
- Other (put size in notes)
-
How many small jacks are required?
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
-
How many medium jacks are required?
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
-
How many large jacks are required?
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
-
What is the condition of the jacks (photo required)
- Great (looks new 5/5)
- Good (no rust 4/5)
- Fair (slight rust 3/5)
- Not good (rusty 2/5)
- Heavily Corroded (needs replacement 1/5)
- No Access
- N/A
-
What is the condition of the chassis (photo required)
- Clean and Painted
- Light Rust Visible
- Consistent Rust Throughout Chassis
- Heavy Rust and Corrosion Throughout Chassis
-
UFI pre installation photos
-
Please take photos of underneath the home to show the access and current condition (*minimum of 4 photos please from each hatch)
-
Is the whole of the underfloor accessible?
-
Bottom of chassis to base of Park home (high point) ? (In cm)
-
Bottom of chassis to base of Park home (low point) ? (In cm)
-
Depth of timber joist to base of Park Home? (***Needed for U-Value Docs)
- 10mm
- 15mm
- 20mm
- 25mm
- 30mm
- 40mm
- 50mm
- 60mm
- 75mm
- 100mm
- If drastically different please state in notes
-
Are there any Dangers Visible? (this may include evidence of rodent activity, leaking pipes, exposed wiring)
-
Please state the dangers
-
Is there any pipe work that will require lagging as part of the installation?
-
What size pipe is present?
-
How much pipe lagging will be required?
- 5m
- 10m
- 15m
- 20m
- 25m
- 30m
- 35m
- 40m
- Other - please state in notes
-
Does the Gas Pipe run under the floor?<br><br>*Please take photos if applicable
-
What is the base made from?
-
Is there pre existing insulation present?
-
What is the condition of the insulation
- The insulation is thin and in very poor condition
- The insulation is very thin but in good general condition
-
What type of insulation is there and how thick is it? (***Needed for U-Value Docs)
-
Anything else to note for the under floor insulation install?
-
*Under the home inspection for External Wall Insulation
-
Once the drip rail has been removed will there be a gap from the park home to the skirting? (leave comments in notes)
-
Number of Jacks (8 required for a Single, 16 required for a double) *Please ensure jacks are supporting the chassis, we don't count jacks not on the chassis.
- 8 (or more)
- 16 (or more)
- The minimum number of Jacks is not present
-
What is the condition of the jacks *Photo required
- Great (looks new 5/5)
- Good (no rust 4/5)
- Fair (slight rust 3/5)
- Not good (rusty 2/5)
- Heavily Corroded (needs replacement 1/5)
- No Access
- N/A
-
What is the condition of the chassis *Photo required
- Clean and Painted
- Light Rust Visible
- Consistent Rust Throughout Chassis
- Heavy Rust and Corrosion Throughout Chassis
Loft Insulation Inspection
-
Is there an accessible loft
- Yes - but I'm not doing a PPHS loft survey today
- Yes - full survey
- No
-
Please take photos of inside the loft here (please also take photos of all 4 corners) Also please take a back up video of the whole of the loft and whatsapp to 07423 629407 (office number) with the address
-
Is there existing loft insulation?
-
What is the thickness of the insulation? ***(2 Photos required with a tape measure in two different areas)
-
What type of insulation?
-
Current condition of the insulation
-
Loft measurements:
-
Height - Highest point
-
Length
-
Width
-
Is the loft clear or is there items/rubbish to be removed/relocated?
- Yes - large amount of items/rubbish to clear
- Yes - small amount of items/rubbish to clear
- No
-
Is the loft boarded?<br><br>*Photo required
-
Is the hatch insulated? (please take photo of the hatch door)
Electrical
-
Are there downlights that need to be covered with a hood?
- No
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- 20
- 21
- 22
- 23
- 24
- 25
- 26
- 27
- 28
- 29
- 30
- Other - see notes
-
Any cables running through the loft?
-
What type of cables? (multi choice)
- Shower cable
- Cooker cable
- Mains incoming cable
- General cables - power + lighting
- Can't see any
- Other - see notes
Pipework
-
Any waterfed pipes run through the loft?
-
Are these pipes insulated?
- Yes
- No - bring around 5 meters of lagging
- No - bring around 10 meters of lagging
- No - bring around 15 meters of lagging
- No - bring around 20 meters of lagging
- No - bring around 25 meters of lagging
- No - bring around 30 meters of lagging
-
Any gas pipes run through the loft?
-
Any water tanks in the loft? (Please take photos if there is a tank)
-
Are they insulated?
-
*Photo Required*<br><br>If the current insulation is less than or equal to 100mm have you filled out the Loft Declaration form, left the document in the loft and taken a photo?<br><br>3 x photos<br><br>1 x upclose so you can see all the details<br>1 x from standing on the loft ladder, showing the hatch and the document<br>1 x far away showing loft hatch, ladder and document in the background
Ventilation Strategy
Inside Inspection of the Park Home
-
Is there a boiler?
-
What is the make and model of the boiler? (please take a photo as well as a written description of the boiler make and model - this is for the Gas Engineer if he needs to extend the flue) Please also add the GC number (or take a clear photo so the Gas Engineers can see it)
-
Please take a photo of the top part of the boiler to check the flue is attached correctly
-
Just incase we need to install a Core Vent for the boiler, please take a photo of a wall where it could vent out of (must be in the room with the boiler) This if for non-condensing boilers, so if the boiler is new, there is no need for this photo.
-
Is there room for a 6 inch Core Vent on this outside wall if required?
-
Is there a drop hole (a vent) in the floor by the boiler? (photo required if there is one)
-
Is there a gas or electric fire in any of the rooms?
-
Please take a photo of the gas fire
-
Is there a core vent?<br><br>*Must be an actual Core Vent
-
Please inform the customer they will need a core vent
-
Please take a photo of the electric fire and the socket/fuse spur it is wired into. We need to ensure that this is electric and not gas as a core vent is needed if there is a gas fire
-
Please take a photo of the Log Burner or Back Burner
-
Is there a core vent?<br><br>*Must be an actual Core Vent
-
Please inform customer they will need a core vent
-
Please take a photo of the Oil Fire
-
Is there a core vent?
-
Please inform the customer they will need a core vent
-
How many bedrooms are there?
- 1
- 2
- 3
- 4
- 5
- 6
- N/A
-
Please take a photo of the Heating Controls / Thermostat
-
What type of lights are in the park home (Please take a photo of 1 light)
Ventilation Strategy
-
Extraction Ventilation:
-
Does the Kitchen have an extractor fan or cooker hood?<br><br>*Please take a photo of the fan or the wall the fan would be installed on if no fan
-
Does the fan work?
-
Does the cooker hood duct to outside?<br><br>*Photo required of cooker hood ducting outside - if already taken or it's not a cooker hood, ignore!
-
Does Bathroom 1 have an extractor fan?<br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Does the En-suite have an extractor fan?<br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Does the Utility Room have an extractor fan?<br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Please list any additional Wet Rooms in the Park Home (Bathroom, WC, Utility Room, En-Suite etc)
- Bathroom 1
- Bathroom 2
- Bathroom 3
- Ensuite 1
- Ensuite 2
- Ensuite 3
- Kitchen
- Utility Room
- WC 1
- WC 2
- WC 3
- Other
- N/A
-
Does Bathroom 1 have an extractor fan?<br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Does Bathroom 2 have an extractor fan?<br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Does Bathroom 3 have an extractor fan? <br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Does Ensuite 1 have an extractor fan?<br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Does Ensuite 2 have an extractor fan? <br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Does Ensuite 3 have an extractor fan? <br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Does the Kitchen have an extractor fan or cooker hood?<br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Does the Utility Room have an extractor fan?<br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Does WC 1 have an extractor fan?<br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Does WC 2 have an extractor fan?<br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Does WC 3 have an extractor fan?<br><br>(Please take a photo of the fan or the wall the fan would be installed on if no fan)
-
Does the fan work?
-
Type in notes the other wet room name and take a photo of the fan or the wall the fan would be installed on
*For City Energy Only Jobs
-
Have you let the customer know that the City Energy funder has said for dMEV continuous fans to be installed, so even if the customer already has fans, these will be replaced with the above fans
Background Ventilation and Door Undercuts
-
Does the Property have adequate background ventilation by means of window trickle ventilation or other room ventilation in habitable rooms?<br><br>***Please take photos here of the existing background ventilation and label the room in/on the photo
-
Please ask the customer if they would want a Window Trickle Vent or a Rectangle Wall Vent to be installed, and fill in the information below.
-
Background Ventilation Strategy
- N/A Background Ventilation is adequate
- Install background vent to Bedroom 1
- Install background vent to Bedroom 2
- Install background vent to Bedroom 3
- Install background vent to Dining Room
- Install background vent to Living Room
- Install background vent to Utility Room
- Install background vent to Study
- Install background vent to Bathroom 1
- Install background vent to Bathroom 2
- Install background vent to Ensuite 1
- Install background vent to Ensuite 2
- Install background vent to Kitchen
- Install background vent to WC
- Install background vent to (add room in notes)
- Install Window Trickle Vent to Bedroom 1
- Install Window Trickle Vent to Bedroom 2
- Install Window Trickle Vent to Bedroom 3
- Install Window Trickle Vent to Dining Room
- Install Window Trickle Vent to Living Room
- Install Window Trickle Vent to Utility Room
- Install Window Trickle Vent to Study
- Install Window Trickle Vent to Bathroom 1
- Install Window Trickle Vent to Bathroom 2
- Install Window Trickle Vent to Ensuite 1
- Install Window Trickle Vent to Ensuite 2
- Install Window Trickle Vent to Kitchen
- Install Window Trickle Vent to WC
- Install Window Trickle Vent to (add room in notes)
-
I have checked with the customer about the age of the windows and the FENSA guarantee
- Windows are over 10 years old and customer is happy for Window Trickle Vents to be fitted
- Windows are under 10 years old and customer is aware the FENSA guarantee will be void if we install the Window Trickle Vent
-
Does the Property have adequate background ventilation by means of Door undercuts of at least 7 600 mm2 beneath all internal doors, above the floor finish, to allow air to move through the dwelling in habitable rooms? ( approx 10mm gap)<br><br>***Please take photos of each habitable room door undercut (With the DOOR CLOSED!) and label the room in/on the photo
-
What doors will need adjusting?
- Bedroom 1 Door
- Bedroom 2 Door
- Bedroom 3 Door
- Kitchen (Door 1)
- Kitchen (Door 2)
- Bathroom Door
- En-Suite Door 1
- En-Suite Door 2
- En-Suite Door 3
- WC Door 1
- WC Door 2
- Living Room (Door 1)
- Living Room (Door 2)
- Dining Room (Door 1)
- Dining Room (Door 2)
- Utility Room Door
- Study Door
- Other (type in notes)
Customer Questions
Questions to ask Customer
-
Colour code (please select the colour code and take a photo of the back of the colour card) PLEASE INFORM THE CUSTOMER - that we will strive to give them the colour they have chosen. However, if the work is scheduled between October 1st and April 1st, we will be applying a White 365 Top Coat, as it dries in just 6 hours, and that's the exclusive colour available during that period.
- Cream (OC80) (White 365 from 1st Oct to 1st April)
- Green (GR71) (White 365 from 1st Oct to 1st April)
- Grey (CG56) (White 365 from 1st Oct to 1st April)
- White (WH89) (White 365 from 1st Oct to 1st April)
- Yellow (LY78) (White 365 from 1st Oct to 1st April)
- N/A - No EWI being installed
- Other
-
Have you let the customer know that any Cladding, Mock Tudor, Corner Quoins, Columns or Decorative Brick Features will be removed and not put back on?
-
Have you let the customer know that we don't paint the soffits, we only Top Coat the walls we insulate?
- Yes - Customer is fine the soffit will not be painted, they will sort out after our install
- Yes - Customer is interested in us colour matching the soffits with the same colour. Please can the office give them a phone call
- Yes
- N/A
- Other: See notes
-
Have you let the customer know that they will need to cutback any shrubbery or plants before we start works?
-
Have you let the customer know the condition of the chassis?
-
Have you let the customer know that we will be putting down floor protection around the home, so some grass may get damaged & decorative items will need to be moved
-
If the customer has an AC unit, does the customer have an engineer they could recommend to move the pipework?
-
Is there anything that needs to be taken off and will be put back on?
-
**Important** Are there any accessibility considerations/requirements to be aware of? I.e. does the customer require the handrail to be installed at M&R stage due to potential injury, are they disabled and require certain items to be fixed back to the wall?
-
Boiler Marketing for Platinum! When was your last boiler service?
-
How old is your boiler
- 1 year old
- 2 years old
- 3 years old
- 4 years old
- 5 years old
- 6 years old
- 7 years old
- 8 years old
- 9 years old
- 10 years old
- 11 years old
- 12 years old
- 13 years old
- 14 years old
- 15 years old
- Other see notes
-
Anything additional needed to mention?
-
Customer Signature
-
I understand and have been explained to, what the installation of Wall Insulation / Underfloor Insulation / Loft Insulation on my property entails and involves
Risk Assessment
-
Any additional risks/hazards to be added to the Risk Assessment:
EPC - Band Jump Clarification
-
The purpose of this document is to outline the reasons why the current property is incapable of jumping two bands and to explain how implementing certain measures will prove advantageous for the said property.
-
Pre-Install EPC:
- (G) 1
- (G) 2
- (G) 3
- (G) 4
- (G) 5
- (G) 6
- (G) 7
- (G) 8
- (G) 9
- (G) 10
- (G) 11
- (G) 12
- (G) 13
- (G) 14
- (G) 15
- (G) 16
- (G) 17
- (G) 18
- (G) 19
- (G) 20
- (F) 21
- (F) 22
- (F) 23
- (F) 24
- (F) 25
- (F) 26
- (F) 27
- (F) 28
- (F) 29
- (F) 30
- (F) 31
- (F) 32
- (F) 33
- (F) 34
- (F) 35
- (F) 36
- (F) 37
- (F) 38
- (E) 39
- (E) 40
- (E) 41
- (E) 42
- (E) 43
- (E) 44
- (E) 45
- (E) 46
- (E) 47
- (E) 48
- (E) 49
- (E) 50
- (E) 51
- (E) 52
- (E) 53
- (E) 54
- (D) 55
- (D) 56
- (D) 57
- (D) 58
- (D) 59
- (D) 60
- (D) 61
- (D) 62
- (D) 63
- (D) 64
- (D) 65
- (D) 66
- (D) 67
- (D) 68
- (C) 69
- (C) 70
- (C) 71
- (C) 72
- (C) 73
- (C) 74
- (C) 75
- (C) 76
- (C) 77
- (C) 78
- (C) 79
- (C) 80
- (B) 81
- (B) 82
- (B) 83
- (B) 84
- (B) 85
- (B) 86
- (B) 87
- (B) 88
- (B) 89
- (B) 90
- (B) 91
- (A) 92
- (A) 93
- (A) 94
- (A) 95
- (A) 96
- (A) 97
- (A) 98
- (A) 99
- (A) 100
-
Predicted Post-Install EPC:
- (G) 1
- (G) 2
- (G) 3
- (G) 4
- (G) 5
- (G) 6
- (G) 7
- (G) 8
- (G) 9
- (G) 10
- (G) 11
- (G) 12
- (G) 13
- (G) 14
- (G) 15
- (G) 16
- (G) 17
- (G) 18
- (G) 19
- (G) 20
- (F) 21
- (F) 22
- (F) 23
- (F) 24
- (F) 25
- (F) 26
- (F) 27
- (F) 28
- (F) 29
- (F) 30
- (F) 31
- (F) 32
- (F) 33
- (F) 34
- (F) 35
- (F) 36
- (F) 37
- (F) 38
- (E) 39
- (E) 40
- (E) 41
- (E) 42
- (E) 43
- (E) 44
- (E) 45
- (E) 46
- (E) 47
- (E) 48
- (E) 49
- (E) 50
- (E) 51
- (E) 52
- (E) 53
- (E) 54
- (D) 55
- (D) 56
- (D) 57
- (D) 58
- (D) 59
- (D) 60
- (D) 61
- (D) 62
- (D) 63
- (D) 64
- (D) 65
- (D) 66
- (D) 67
- (D) 68
- (C) 69
- (C) 70
- (C) 71
- (C) 72
- (C) 73
- (C) 74
- (C) 75
- (C) 76
- (C) 77
- (C) 78
- (C) 79
- (C) 80
- (B) 81
- (B) 82
- (B) 83
- (B) 84
- (B) 85
- (B) 86
- (B) 87
- (B) 88
- (B) 89
- (B) 90
- (B) 91
- (A) 92
- (A) 93
- (A) 94
- (A) 95
- (A) 96
- (A) 97
- (A) 98
- (A) 99
- (A) 100
-
Please state the reason for why the property is unable to jump 2 bands with the current measures
-
What measures are required to do the 2 band jump?
- EWI
- UFI
- Loft
- ASHP
- Solar
- LED Lights
- TTZC (Time and Temperature Zone Control)
- Upgrade Heating Controls
- Upgrade Boiler
- Double Glazing
- Other - See Notes
Permissions
-
Who owns the park home site?
- Aldingbourne Park
- Avondale Park
- Beechfield Park
- Berkley Site Site
- Climping Park Site
- Deanland Wood Site
- East Beach Park
- Fangrove Park
- Forest Way
- Grange Park
- Grange Park
- Haulfryn Site
- Havenwood Site
- Henderson Park
- Longacre Park
- McAllister Site
- Milfarm Residential Park Home Estate Site
- Moorgreen Park
- Park Home Living Site
- Roundstone Park
- Silver Lakes
- Starglade Site
- Tingdene Site
- The Marigolds
- The Willows
- Turners Hill Site
- Willowbrook Park
- Other (add in notes)
-
Double check but these parks don't require a permission to work
-
Double check but these sites *REQUIRE a permission to work
-
Permission to Work Required?
Documents Required
-
Please select the managing agent
- City Energy: LAD 3
- Agility Eco: LAD 3
- Agility Eco: HUG
- Test Valley
- Amber Living
- Other
-
Photo of the signed Purchase Agreement (PPHS Purchase Agreement/Contract)
-
Photo of the signed City Energy Contract
Have you got the following evidence? (PLEASE DO NOT ATTACH HERE - send separately via Google Drive or upload straight to the CRM)
-
Proof of Income: 3 months Bank Statements (most recent 3 months statements, and all pages to be uploaded)
-
Source of income (Like DWP Pension)
-
Proof of Ownership (original paperwork if possible and not a pitch fee review - pitch agreement usually fine)
-
Just a reminder, we will need
EPC rating of an E, F or G -
Other (If there is anything else required you can add it here)
-
Photo of the signed Purchase Agreement (PPHS Purchase Agreement/Contract)
-
Photo of the signed Warmer Homes Contract<br><br>(Please Genius Scan these and email them to your project manager, thanks!)
Have you got the following evidence? (PLEASE DO NOT ATTACH HERE - send separately via Google Drive or upload straight to the CRM)
-
Proof of Income: *For the whole household<br><br>Payslips or Pension Statement ONLY
-
Along with the above, we also need 3 months Bank Statements (most recent 3 months statements, and all pages to be uploaded)
-
Proof of Ownership (original paperwork if possible and not a pitch fee review - pitch agreement usually fine)
-
Utility Bill (dated within 6 months)
-
Other (If there is anything else required you can add it here)
-
Photo of the signed Purchase Agreement (PPHS Purchase Agreement/Contract)
-
Photo of the signed Warmer Homes Contract<br><br>(Please Genius Scan these and email them to your project manager, thanks!)
Have you got the following evidence? (PLEASE DO NOT ATTACH HERE - send separately via Google Drive or upload straight to the CRM)
-
Proof of Income: *For the whole household<br><br>Payslips, Pension Statement or P60
-
Along with the above, we also need 3 months Bank Statements (most recent 3 months statements, and all pages to be uploaded)
-
Proof of Ownership (original paperwork if possible and not a pitch fee review - pitch agreement usually fine)
-
Utility Bill (dated within 6 months)
-
Other (If there is anything else required you can add it here)
-
Photo of the signed Purchase Agreement (PPHS Purchase Agreement/Contract)
Have you got the following evidence? (PLEASE DO NOT ATTACH HERE - send separately via Google Drive or upload straight to the CRM)
-
Proof of Income: 3 months Bank Statements (most recent 3 months statements, and all pages to be uploaded)
-
Proof of Ownership (original paperwork if possible and not a pitch fee review - pitch agreement usually fine)
-
Other (If there is anything else required you can add it here)
-
Lucky you, we don't need any documents!
-
Other (If there is anything else required you can add it here)
-
Other (If there is anything else required you can add it here)