PASMA Tower Inspection
-
Height of tower
-
Is there a copy of the manufactures instruction manual available and easily read
-
Do you have a risk assessment for PASMA towers
-
The environment is safe to erect the tower
-
The castors or base plates are in full contact with the ground and sharing the weight of the tower
-
All brakes are applied
-
The adjustable legs are only used to level and not to gain height
-
The tower is level in all planes
-
Built on firm and stable ground
-
Stabilisers are fitted and are correct size for tower height
-
Feet are in full contact with the ground and secured
-
The stabilisers are positioned so that they form a square
-
The bracing pattern used is in accordance with the manufactures instruction manual
-
All hooks on the braces are fully engaged
-
Handrails and mid guard rails are fitted and in correct position
-
Interlocking device, locking frames together are all wmgaged
-
Platforms are in correct position
-
Trap doors open to the outboard side of the tower
-
If single width do all platforms have trap doors
-
If wind locks fitted they are engaged
-
Toe boards fitted working platforms
-
If the tower is tied in it has been checked against the manufactures instruction manual
-
Take a photo of the completed tower
-
Full Name of person inspecting